[. . . ] Colour CCTV Cameras
WV-CPR650/WV-CPR654
ENGLISH
(Lens : option)
Before attempting to connect or operate this product, please read these instructions completely.
FRANÇAIS
ENGLISH VERSION
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
For U. K.
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY.
WARNING
THIS APPARATUS MUST BE EARTHED IMPORTANT The wires in this mains lead are coloured in accordance with the following code. Green-and-yellow: Earth Blue: Neutral Brown: Live As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows. The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol I or coloured green or green-and-yellow. The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N or coloured black. [. . . ] -21-
X ON/X OFF This item is used to select applying the flow control or not. Select NOT USE (not apply flow control) or USE (apply flow control) and press . WAIT TIME This item is used to select the wait time to re-transmit after confirming that no data is received from the controller. ALARM DATA This item is used to select the way of transmitting the alarm data. Select the alarm data transmission mode from following parameters: POLLING: Transmit the alarm data to the controller to request from the controller. AUTO 1: Transmit the alarm data each time the alarm signal is received. -22-
DELAY TIME This item is used to select the time to transmit the acknowledge request when communicating on a twoline connection. Note: This item appears only when a two-line connection is used.
· Installation of Software for RS485 Communication
1. When the window that says "Please insert the disk labeled: "Disk 2" into drive C:" appears on the monitor screen, insert the Install Disk 2 and press . When the installation is completed, the window that says "485_GUI Setup was completed successfully. " appears on the monitor screen. After installation of 485_GUI Setup is completed, open 485_GUI Setup, and set the RS485 communication parameters.
· CAMERA Set Up
Move the cursor to CAMERA of the SET UP menu and press . The CAM SET UP menu appears on the monitor screen.
Character Cursor 0123456789 ABCDEFGHIJKLM NOPQRSTUVWXYZ (). , '":;&#!?= +-*/%$ÄÜÖÆÑÅ SPACE POSI RET END RESET . . . . . . . . . . . . . . . . Camera Identification (CAMERA ID) Setting
You can use the camera identification (CAMERA ID) to assign a name to the camera. You can select whether to have the camera ID displayed on the monitor screen or not.
** CAM SET UP ** CAMERA ID OFF ALC/ELC ALC SHUTTER --AGC ON SENS UP OFF SYNC INT WHITE BAL ATW MOTION DET OFF LENS DRIVE DC RET
CAMERA ID menu 3. Move the cursor to the character you want to change by pressing / / / . (The pointer in the editing area moves to the right automatically at this moment. ) 5. To enter a blank space in the CAMERA ID Move the cursor to SPACE and press . Move the cursor to the editing area by pressing .
To edit the CAMERA ID 1. Then move the cursor to the character area and select a new character. To erase all characters in the editing area Move the cursor to RESET and press . The display shown below appears and the CAMERA ID starts blinking.
Blinking
Notes: · The CAMERA ID stops at the edges of the monitor screen. · The CAMERA ID moves faster if any of / / / is kept pressed for a second or longer. [. . . ] To set MASK SET, proceed as described in steps 2 to 4 of "ALC mode with SUPER-D OFF and ELC mode" on page 26. Move the cursor to the ALARM parameter and select ON or OFF to set the alarm in the DISPLAY MODE. Note: When the system controller WV-RM70, WVCU550 or WV-CU550A is used with this model, select OFF for ALARM. To raise detection sensitivity, press to return to the MOTION DETECT menu. [. . . ]