[. . . ] Combination Camera WV-CS650 WV-CS654 WV-CSR650 Before attempting to connect or operate this product, please read these instructions completely ESPAÑOL FRANÇAIS DEUTSCH ENGLISH ENGLISH VERSION We declare under our sole responsibility that the product to which this declaration relates is in conformity with the standards or other normative documents following the provisions of Directives EEC/73/23 and EEC/89/336. Noi dichiariamo sotto nostra esclusiva responsabilità che il prodotto a cui si riferisce la presente dichiarazione risulta conforme ai seguenti standard o altri documenti normativi conformi alle disposizioni delle direttive CEE/73/23 e CEE/89/336. Wij verklaren als enige aansprakelijke, dat het product waarop deze verklaring betrekking heeft, voldoet aan de volgende normen of andere normatiefve dokumenten, overeenkomstig de bepalingen van Richtlijnen 73/23/EEC en 89/336/EEC. Vi erklærer os eneansvarlige for, at dette produkt, som denne deklaration omhandler, er i overensstemmelse med den følgende standarder eller andre normative dokumenter i følge bestemmelserne i direktivene 73/23/EEC og 89/336/EEC. [. . . ] CLOSE OPEN RET - 15 - q Dwell Time Setting · Move the cursor to DWELL TIME and set a dwell time by moving the joystick to the left or right. Dwell time changes as follows: 2S 3S 5S 10S 30S 1MIN 2MIN 3MIN 4MIN Preset setting menu PRESET NO. 15*H POSITION SET PRESET ID ALC/MANUAL DWELL TIME SCENE FILE ON ALC 2S 1 The letter S signifies second(s) and MIN minute(s). RET DEL q Scene File Setting 1. To set a scene file number Move the cursor to SCENE FILE and select a scene file number (1 to 10, or OFF) by moving the joystick to the left or right. No scene file is selected at OFF. Preset setting menu PRESET NO. 15*H POSITION SET PRESET ID ALC/MANUAL DWELL TIME SCENE FILE ON ALC 2S 1 RET DEL 2. To set scene file details Move the cursor to a scene file number and press the CAM (SET) key. Shutter speed: Page 23 AGC: Page 23 Electronic sensitivity enhancement: Page 23 White balance: Page 25 Motion detector: Page 27 Auto focus: Page 28 Scene file setting menu * * SCENE FILE 1 ** SHUTTER AGC SENS UP WHITE BAL MOTION DET AF MODE RET OFF ON OFF ATW ON MANUAL q To return to the PRESET NUMBER SET Menu · Move the cursor to RET and press the CAM (SET) key. The PRESET NUMBER SET menu appears with the * mark on the right of the preset position number. Preset setting menu PRESET NO. 15*H POSITION SET PRESET ID ALC/MANUAL DWELL TIME SCENE FILE ON ALC 2S 1 RET DEL q To return to the setup menu · Move the cursor to RET and press the CAM (SET) key. PRESET NUMBER SET menu * PRESET NUMBER SET * 1* 5* 9* 13* 17 21 25 29 ID: 33-64 2* 6* 10* 14* 18 22 26 30 RET 3* 7* 11* 15*H 19 23 27 31 4* 8* 12* 16 20* 24 28 32 - 16 - s Deleting Preset Positions 1. Move the cursor to PRESET 1* and select the position number to be deleted by moving the joystick. Setup menu *** SET UP MENU *** PRESET 1* MAP HOME POSITION SELF RETURN AUTO MODE FLIP-A-CHIP LOCAL/REMOTE CAMERA 15 10MIN AUTO PAN ON LOCAL 2. Press the CAM (SET) key to display the preset setting menu. Preset setting menu PRESET NO. 15*H POSITION SET PRESET ID ALC/MANUAL DWELL TIME SCENE FILE RET DEL ON ALC 2S 1 3. This deletes the preset position and the PRESET NUMBER SET menu appears. Note: Your selected preset number is canceled only in SEQ and SORT mode. The previously set parameters (for PAN, TILT positions, etc. ) are not changed. If you wish to change these parameters, you must set them again. PRESET NUMBER SET menu * PRESET NUMBER SET * 1* 5* 9* 13* 17 21 25 29 ID: 33-64 2* 6* 10* 14* 18 22 26 30 RET 3* 7* 11* 15 19 23 27 31 4* 8* 12* 16 20* 24 28 32 s Home Position Setting 1. To set a position number for the home position Move the cursor to HOME POSITION and select the desired position number by moving the joystick to the left or right. Select OFF if you are not using the home position function. Setup menu *** SET UP MENU *** PRESET 1* MAP HOME POSITION SELF RETURN AUTO MODE FLIP-A-CHIP LOCAL/REMOTE CAMERA 15 10MIN AUTO PAN ON LOCAL s Self Return Setting · To set a time-out parameter for return to the home position Move the cursor to SELF RETURN and select a return time by moving the joystick to the left or right. Return time changes as follows: 1MIN OFF 2MIN 3MIN 5MIN 10MIN 20MIN Setup menu *** SET UP MENU *** PRESET 1* MAP HOME POSITION SELF RETURN AUTO MODE FLIP-A-CHIP LOCAL/REMOTE CAMERA 15 10MIN AUTO PAN ON LOCAL 60MIN 30MIN MIN signifies minute(s). - 17 - s Auto Mode Setting 1. To set auto mode Move the cursor to AUTO MODE and select a mode by moving the joystick to the left or right. Modes change as follows: OFF SEQ SORT AUTO PAN Setup menu *** SET UP MENU *** PRESET 1* MAP HOME POSITION SELF RETURN AUTO MODE FLIP-A-CHIP LOCAL/REMOTE CAMERA 15 10MIN AUTO PAN ON LOCAL 2. When AUTO PAN is selected, set details as follows: Move the cursor to AUTO PAN and press the CAM (SET) key to display the AUTO PAN setting menu. AUTO PAN setting menu ** AUTO PAN ** POSITION SET SPEED ENDLESS DWELL TIME RET START END . . . I. . . . To set a panning start position and panning end position Follow the steps below. (2) Move the joystick to the left or right to select a panning start position and press the CAM (SET) key. (3) Move the joystick to the left or right to select a panning end position and press the CAM (SET) key. [. . . ] Sideway cable exit Pass the cables through the cutout made in the diecast case and decoration cover (refer to item a, INSTALLATION). Ring of the Fall Prevention Wire 5. Mount the camera on the camera mounting angle and rotate the camera clockwise. 15° b. Top cable exit Push the decoration cover against the camera mounting angle. 6. Tighten the camera fixing screw with a screwdriver. - 33 - When using the optional bracket for mounting refer to the Operating instruction for the WV-Q105, WV-Q106, WV-Q107 or WV-Q108. CONNECTIONS Precaution: The following connections should be made by qualified service personnel or system installers in accordance with all local codes. 220 - 240V AC (WV-CS650, WV-CSR650) 24V AC (WV-CS654) Data cable (Only for WV-CSR650) RS485 cable Video Output Cable BNC Plug Coaxial Cable (5C-2V) To Video IN (CAMERA IN) BNC Plug T The coaxial cable length (RG-6/U, 5C-2V) for the connection is up to 1 200 meter (4, 000 ft. ) Note: When powered up, the unit performs a self-check (including one panning, tilting, zooming and focusing operation). q Power supply connection Recommended wire gauge sizes for 24V AC line Copper wire size (AWG) Length of Cable (Approx. ) (m) (ft) #20 #18 #24 #22 (0. 22mm2) (0. 33mm2) (0. 52mm2) (0. 83mm2) 20 65 30 100 45 160 75 260 Accessory Connector Information Pin No. [. . . ]