[. . . ] ELECTRONIC CASH REGISTER
MODEL
ER-A450
INSTRUCTION MANUAL
CAUTION: The cash register and the remote drawer should be securely fitted to the supporting platforms to avoid instability when the drawers are open. CAUTION: The socket-outlet shall be installed near the equipment and shall be easily accessible. VORSICHT: Die Netzsteckdose muß nahe dem Gerät angebracht und leicht zugänglich sein. ATTENTION: La prise de courant murale devra être installée a proximité de l'équipement et devra être facilement accessible. [. . . ] Cashier code
53
Cashier name
PGM 1
PGM 2
1514
You can program a maximum of 8 characters (cashier name) for each cashier. Select the characters you want to program referring to section "2 How to program alphanumeric characters" in chapter "PRIOR TO PROGRAMMING. "
Procedure
To program spaces * 1514
.
Cashier code (1 - 99)
Character keys (max. 8 digits)
:
;
*: A cashier code you have programmed for the cashier by job code 1500
Example
Key operation
Print
1514 . 11 MAYER :
;
Functional programming for cashiers
Procedure
* 2510
PGM 2
2510
To keep the current setting Cashier code (1 - 99)
.
Selection: Disable Enable Yes No
**A B C D E
:
Entry: 1 0 1 0 0 1 or 2 0
;
The current setting is displayed.
*: A cashier code you have programmed for the cashier by job code 1500
**
Item: A B
Guest check copy VAT shift
C and D Always enter 0. 11 00001 :
;
E(Drawer no. ) A through D
54
Clerk code
PGM 1
PGM 2
1400
You can assign a clerk code to each of 99 clerks. If you need this function, consult your dealer.
Procedure
To keep the current setting 1400
.
Clerk no. (1 to 99)
*Clerk code (0 - 99)
:
;
The current setting is displayed.
*: Programming clerk code "0" inhibits entries of the clerk code.
Example
Key operation
Print
1400 . Clerk code
;
Clerk name
PGM 1
PGM 2
1414
You can program a maximum of 8 characters (clerk name) for each clerk. Select the characters you want to program referring to section "2 How to program alphanumeric characters" in chapter "PRIOR TO PROGRAMMING. "
Procedure
To program spaces * *: A code you have programmed for the clerk by the job code 1400. 8 digits)
:
;
*: A clerk code you have programmed for the clerk by the job code 1400
Example
Key operation
Print
1414 . 11 NILS :
;
55
10 Programming various functions
Programming for optional feature selection
PGM 2
2616
OP X/Z mode availability When a cashier needs to take the cashier/clerk X or Z report, he or she will use the OP X/Z mode. This programming determines whether he or she will be allowed to use this mode.
Note
You can take cashier/clerk X and Z reports in the X1/Z1 mode regardless of the above programming.
Paid out in the REG-mode Refund key in the REG-mode Direct void in the REG-mode Indirect void in the REG-mode Subtotal void in the REG-mode First item direct void Printing of the number of purchased items Journal print form You may choose either of the following forms. · Detailed journal print that shows the details of all entries - the same information as printed on the receipt. · Summary journal print that shows information about all entries other than normal department entries (entries into "+" departments and their associated "+" PLUs). Zero skip for various reports VAT/tax amount, taxable amount and net amount printing on the receipt/journal VAT shift type VAT shift by cashier: VAT shift is performed by the operation of a cashier who has been assigned to do the VAT shift operation (Refer to job# 2510). VAT shift by shift key: VAT shift is performed by pressing the VAT shift key. No sale in REG-mode Finalization when the subtotal amount is zero in the REG mode Printing of the exchange 1 total amount and change amount on the receipt/journal Total and change amounts in exchange 1 currency are printed respectively below each of the total and exchange amounts in domestic currency. Footer graphic logo printing Credit counting when received-on-account/paid out finalized with the credit key Separator line in the report Link PLU printing on the receipt
Procedure
To keep the current setting 2616 ** P (1 to 13) The current setting is displayed.
.
*ABCDEFGH
:
;
56
**P: 1 * Item:
A B C D E F G H OP X/Z mode Paid-out in REG-mode Always enter 0. Refund key entry in the REG-mode Direct void in the REG-mode Indirect void in the REG-mode Subtotal void in the REG-mode Always enter 0.
Selection: Enable Disable Enable Disable Enable Disable Enable Disable Enable Disable Enable Disable
Entry: 0 1 0 1 0 0 1 0 1 0 1 0 1 0
**P: 2 * Item:
A The first item direct void
Selection: Enable Disable No Yes Detailed Limited
B and C Always enter 0. Journal print form
G and H Always enter 0.
Entry: 0 1 0 0 1 0 0 1 0
**P: 3 * Item: A B C D E F G H
Selection: Always enter 0. Zero skip in clerk report Zero skip in cashier report Zero skip in transaction report Zero skip in department report Zero skip in PLU report Zero skip in hourly report Zero skip in daily net report Yes No Yes No Yes No Yes No Yes No Yes No Yes No
Entry: 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1
57
**P: 4 * Item: A and B Always enter 0. C VAT/tax amount printing on the receipt/journal D Taxable amount printing on the receipt/journal E Net amount printing on the receipt/journal F to H **P: 5 Item: A to C D E to H Always enter 0.
Selection: Yes No Yes No Yes No
Entry: 0 0 1 0 1 0 1 0
*
Selection: Always enter 0. [. . . ] · Is the mode switch set properly at the "REG" position?· Is the paper roll properly installed?
(4) No journal paper is taken up. (5) Printing is unusual.
Error code table
When the following error codes are displayed, press the c key and take a proper action according to the table below. Error code E01 E02 E03 E04 E05 E07 E11 E12 E22 E23 E31 E32 E33 E34 E35 E36 E37 E58 E67 E76 Error status Registration error Misoperation error Undefined code is entered. [. . . ]