[. . . ] Non-compliance could impair the function and lead to damage of the plastic housing of the CF Card Printer. To these instructions Symbol Meaning Be sure to observe Important information Explanation Indicates situations which might lead to damage of the MELAnet Box if not complied. Indicates important information. Example of font type Batch output Meaning Software citation Explanation Words or phrases appearing on the ?display of the autoclave are marked as software citations. 5 in Figure 1. Chapter 6 ­ Logging Cross-reference Figure 1/(5) Cross-reference Symbols on the unit The symbol of the struck out trashcan identifies a device that may not be disposed with domestic waste. An appropriate and competent disposal must be carried out by the marketing party. [. . . ] In this case, the green power LED and the red data LED blink together with brief interruptions. Save the sterilization logs stored on the CF card by copying them to your computer with the delivered card reader device. 5 Chapter 3 ­ Initial start-up MELAflash CF Card Printer Chapter 3 ­ Initial start-up Connect MELAflash For the power supply, connect the cable of the delivered plug-in power supply unit to the right-hand socket (see 4, Fig. Connect the RS232 interface of the serial cable to the serial data connection of the autoclave. We recommend you to tightly screw both the knurled screws on the serial connection to avoid them from getting loose or inadvertently being pulled out. For more detailed information about connecting the serial cable, consult the Operating Manual. Insert the MELAflash CF card Insert the delivered MELAflash CF card into the slot on the front of the MELAflash CF Card Printer. Warning! Make sure the card is facing the right direction and do not use force to insert it into the slot. If you do not observe this precaution, the CF card or the CF Card Printer can be damaged. Warning! Only remove the MELAflash CF card from the CF Card Printer when the red data LED is not lit up. If you pull the CF card out of the CF Card Printer while the red data LED is still lit up, data saved on the card can be lost. Format MELAflash CF card At delivery the CF card is already formatted, i. e. If it should nevertheless ever be necessary to format the CF card, always do so with the CF Card Printer. Insert the CF card into the slot as far as you can before it makes contact with the limit stop, but is faced in the right direction in the slot. Keep the "format" button pressed down (about 7 sec) until the red data LED begins to blink repeatedly. This signifies that the CF Card Printer is in formatting mode for a short time (about 5 sec). 6 Chapter 3 ­ Initial start-up MELAflash CF-Card-Schreiber While the red data LED is blinking, insert the MELAflash CF card completely into the slot of the MELAflash CF Card Printer until the limit stop. When the formatting is completed, the red data LED goes out. All saved data on the CF card is deleted during formatting. Warning! Initialise the MELAflash CF Card Printer on the autoclave In order to be able to save sterilization logs on the MELAflash CF Card via the CF Card Printer, you have to set the MELAflash CF Card Printer as output medium on the autoclave. The settings you make depend on which device software is installed on your autoclave. Settings for the autoclave software version up to V3. 34 Switch on the power at the autoclave and wait until the display shows the initial state. Select the setup menu Function by simultaneously briefly pressing the (+) and (­) KEYS. The display shows Data transfer ­ no printer, if a printer has not yet been set. Navigate with the (+) KEY until the display shows Data transfer ­ external PC. Press the (S) KEY twice to exit the menu and return to the initial state. In order to save the sterilization logs on the CF card directly after the end of a sterilization program, you must activate the option on the autoclave for immediate printout. Set immediate printout of the logs Select the Setup Menu Function by short simultaneous pressing of the (+) and (-) KEY. Navigate with the (+) or (-) KEY until the submenu displays Immediate printout Yes/ No. [. . . ] Faulty log file If there is an error in the data transmission from the autoclave to the CF Card Printer, i. e. while a logfile is being saved on the CF card, the system creates the directory ERROR. Here the red data LED and the green power LED also steadily blink alternately (see Table, row 06 on p. To reset the error condition, press briefly on the "Format" button on the top of the MELAflash CF Card Printer (see 4, Fig. [. . . ]