[. . . ] and the logo are registered trademarks of Icom Incorporated (Japan) in the United States, the United Kingdom, Germany, France, Spain, Russia and/or other countries.
i
PRECAUTIONS
R WARNING HIGH RF VOLTAGE!NEVER
attach an antenna or internal antenna connector during transmission. Always have two people available to carry, lift or turn over the transceiver.
R WARNING!NEVER operate the transceiver
with a headset or other audio accessories at high volume levels. [. . . ] o To cancel the tone squelch, push [TONE] (MF6) to clear "TSQL. "
· Available tone frequencies
67. 0 69. 3 71. 9 74. 4 77. 0 79. 7 82. 5 085. 4 088. 5 091. 5 094. 8 097. 4 100. 0 103. 5 107. 2 110. 9 114. 8 118. 8 123. 0 127. 3 131. 8 136. 5 141. 3 146. 2 151. 4 156. 7 159. 8 162. 2 165. 5 167. 9 171. 3 173. 8 177. 3 179. 9 183. 5 186. 2 189. 9 192. 8 196. 6 199. 5 203. 5 206. 5
(unit: Hz)
210. 7 254. 1 218. 1 225. 7 229. 1 233. 6 241. 8 250. 3
4-34
RECEIVE AND TRANSMIT
4
Data mode (AFSK) operation
When operating AMTOR or PACKET with your TNC and/or PC software, consult the manual that comes with the TNC and/or the software.
Band keys
q Connect a PC and TNC to the transceiver. r Push DATA to turn data mode ON.
· One of "-D1, " "-D2" or "-D3" is additionally appears. to select data mode 1 (D1), 2 (D2) and 3 (D3) in sequence.
[AF]
SSB
AM/FM
DATA
Main dial
t Rotate the main dial to tune to the desired signal and decode it correctly.
· Also use the tuning indicator of the TNC or software. · During SSB data mode, the 1/4 tuning function can be used for critical tuning.
Appears
y Operate the PC (software) or TNC to transmit.
· When operating in SSB data mode, adjust the TNC output level so that the ALC meter reading doesn't go outside the ALC zone.
NOTE: When SSB data mode is selected, the audio input from the [ACC1 (pin 6)] is used for transmission instead of [MIC]'s. 12-7, 12-8))
The fixed condition is used for SSB data transmission as follows: · [COMP] : OFF · Tx bandwidth : MID · Tx Tone (Bass) : 0 · Tx Tone (Trebles): 0
· Tone-pair example
2325 Hz 200 Hz 2125 Hz
For your information Carrier frequency is displayed when SSB data mode is selected.
See the diagram left for the tone-pair example.
Carrier frequency (displayed frequency)
4-35
FUNCTIONS FOR RECEIVE
Section
5
Spectrum scope screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 D Center mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 D Fixed mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 D Mini scope screen indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 D Scope set mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 Preamplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9 Attenuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5, 5-6)
t Push [ATT] F-2 several times to activate an attenuator or turn the attenuator OFF.
· 10, 20 and 30 dB attenuators are available. to turn OFF the attenuator.
y Push [MARKER] F-3 to turn the marker for transmit frequency ON or OFF.
· " T " displays the marker at the transmit frequency. · "<<" or ">>" appears when the marker is out of range. · The spectrum scope shows the transmit signal while transmitting. Peak levels are displayed in the background of the current spectrum in a different color until the receive frequency changes. This can be deactivated and the waveform color can be set in scope set mode. 5-5)
· Scope spurious signal example Spurious signals may be received on the spectrum scope screen regardless of the transceiver's state (TX or RX). This does not indicate a transceiver malfunction.
u Push [HOLD] F-4 to freeze the current spectrum display.
· " HOLD " appears while the function is in use. · The peak hold function can be deactivated in scope set mode.
i Push EXIT/SET to exit the scope screen. Push [ATT] F-2 several times to activate the spectrum scope attenuator in this case. They are generated in the internal scope circuit and do not indicate a transceiver malfunction.
Scope spurious example 5-2
FUNCTIONS FOR RECEIVE
5
D Fixed mode
Displays signals within the specified frequency range. [. . . ] i Click [Yes] if you want to start the firmware update.
Depending on the updated contents, the sub CPU and/or DSP firmware will automatically be updated when rebooting the IC-701 and this will take approx. DO NOT turn the IC-701 power OFF until the normal operational screen appears, in such case.
Do you wish to start the firmware update?
Click to start the firmware update
16-8
UPDATING THE FIRMWARE
16
IC-701 Firm Utility
o The screen as at left is displayed.
· The following dialog appears in the IC-701 display.
Version 1. 00 (C) 2007 Icom Inc.
Firmware File Name
IC-701 IP Address
RWARNING!: NEVER turn the IC-701 power OFF at this stage. The transceiver firmware will be corrupted.
Connecting to the IC-701. Please wait a while.
!0 Click [OK] to finish the firmware update.