[. . . ] The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance. This symbol means: indoor use only This symbol means: Read instructions This symbol means: Lamp Control Gear To prevent fire or shock hazard, do not expose this appliance to rain or moisture. To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full performance or may even cause damages. [. . . ] This input receives instructions from a DMX-controller or from another Micro Led Manager when used in master/slave mode. DMX OUTPUT: 3pin female XLR-connector used to connect the Micro Led Manager with the next DMX appliance in the chain or with another Micro Led Manager when used in master/slave mode. The Micro LED Manager can also be used as controller for other LED projectors like for example "LED PAR56/64" 4. DIP SWITCHES: when used in DMX mode (DIP10 = OFF) you can set the DMX-starting address of the unit. When used in stand-alone mode (master, DIP10 = ON), you can use the DIP-switches to set different pre-programmed options. AUTO DMX ADDRESS BUTTON: see further to learn how to set the DMX address easily. OUTPUT TERMINALS: used to connect different 24Vdc common anode LED projectors. Load: 50W) You can connect any 4pole electrical wire to connect the LED-projectors to this output. However to make life easier for you we suggest using the special CCM-50 cable (role = 50m). This external switch can be used to switch the general output of the Micro LED Manager on/off. (external blackout) See further for more information on how to connect the analog switch. WALL DIMMER INPUT: used to connect our LED WALL DIMMER, a small LED controller that fits in any standard "electrical wall box". See further for more information on how to connect the LED WALL DIMMER. STATUS LED: shows the status of the unit, should blink when DMX is detected. In the chapter DMX-addressing, we explain how DMX-addressing can be done. DIP10 = ON Master operation (stand-alone) Use the dipswitches 1~9 to set the mode, speed, patterns, fixed color color. The electrical installation should be carried out by qualified personal only, according to the regulations for electrical and mechanical safety in your country. How to connect the LED-projectors to the output of the unit: Important: Switch the Micro Led Manager OFF before you install the LED-projectors!The maximum total load of the Micro Led Manager is 50W, spread over 3 colors: each of the 3 colors has a max. lED STRIP): Use the supplied conversion cable and connect the internal 4 wires to the corresponding 4 terminals of the MICRO LED MANAGER. Fix all projectors properly and daisy chain the in/output cables until you reach the maximum allowed load. Make sure not to exceed the maximum allowed load: White wire: This is the common wire (anode) Red wire: This the power for the red LEDs (max. [. . . ] Set the DMX-channel, that you want to assign as DMX-start address on your Micro LED Manager, to maximum (value 255) Press the "Auto DMX address" button (6) on the first Micro LED Manager in the chain for about 5seconds. The first Micro LED Manager in the chain will receive the DMX-start address you chose and it will automatically calculate and program the DMX addresses of all the other units in the DMX-chain!Connect the optional LEDCON-02 (or LEDCON-01) for remote control: In most cases the MICRO LED MANAGER will be installed on a wall, close to the LED-projectors. If you want to have easy access to its functions, you can connect the LEDCON-02 (or LEDCON-01) remote controller to the (first) Micro Led Manager. [. . . ]