[. . . ] Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7109 Fax: (81)75-344-7149 Regional Headquarters OMRON EUROPE B. V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel:(31)2356-81-300 Fax:(31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U. S. A. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO. , LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, Pu Dong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Note: Specifications subject to change without notice. [. . . ] The processes that are being executed can be understood at a glance, which simplifies monitoring process status. To acquire a CS/CJ-series PLC with unit version 4. 0, contact your OMRON representative. 6 Sequential function charts (SFC) is a language used to express the flow of process steps as graphical charts that combine steps and transitions. Structured text (ST) is a high-level language for industrial control that allows programming numerical processing and repetition processing more simply than ladder diagrams. ST complies with the IEC 61131-1 standard. 7 Even Less Time Required to Design Networks Transferring Routing Tables to Networks Automatic Search for Computer Port for Automatic Online Connection Version Upgrade Routing tables can be transferred from one location to multiple PLCs! The Popular Automatic Online Connection to PLCs Is Now Even Easier! The computer's serial ports are automatically searched when an automatic online connection is used, so it is no longer necessary to individually specify the port used. Version Upgrade Routing tables can be set and transferred from one PLC to other PLCs on a network without reconnecting cables. (See note. ) Setting and transferring routing tables required a lot of time onsite to reconnect the cables for each PLC. Network The computer port (e. g. , COM2 or COM3) had to be specified using a separate menu command for selecting the connection port when an automatic online connection was performed with the PLC connected to the computer's USB port (except for COM1). Serial connection Routing tables can be set and transferred from a PLC in just one location! Work is greatly simplified by the ability to set and transfer routing tables from one location to all the PLCs on a network of the same layer. Work is easy! Note: Routing tables cannot be set across network layers (same as previously). The PLC connected to the computer must be a CS/CJ-series PLC with unit version 4. 0 or later. Supported for unit version 4. 0 or later. No communications port settings are required!Only the connectable communications ports are displayed, so online connection is easy. Online connection can be easily made with two clicks of the mouse. There's no need to worry whether online connection at the worksite will be possible when an error occurs. Easy online connection with two clicks! Support is provided with CS/CJ-series PLCs with unit version 4. 0 or later. To acquire a CS/CJ-series PLC with unit version 4. 0, contact your OMRON representative. of the port used on the computer Direct Ethernet Connections Version Upgrade Version Upgrade Transferring routing tables is easy using a direct Ethernet connection! Routing tables can be transferred from a computer to a PLC connected with an Ethernet cable. Transfer to computer from a DeviceNet network can be resumed! If communications fail when uploading DeviceNet network data (slave data) using the CX-Integrator, uploading can be resumed from the point where failure occurred, thereby greatly shortening the time for transferring network data to the computer. Start Transfer time onsite Completed Transfer Failure Retransfer Resuming transfer to computer No Time The maximum number of Controller Link data link send words per node has been increased from 1, 000 to 4, 000! A separate Peripheral Cable was required to transfer routing tables when the computer and the PLC were directly connected using Ethernet. Work for making routing table settings onsite was troublesome. No Peripheral Cable required! Support is provided for Controller Link Units (soon to be released), which have increased the maximum number of send/receive words per Unit fourfold from the previous 1, 000 words to 4, 000 words when data links are used (see note). This can be used to increase the amount of data shared between PLCs, such as for exchanging data on quality. Note: CS1W-CLK13/23/53, CJ1W-CLK23, and 3G8F7-CLK13/23/53. Resuming transfer to computer Yes Much shorter! Version 3. 2 of the CX-Thermo Routing tables can be transferred with the PLCs connected to an Ethernet network. Routing tables can be transferred from the computer to a PLC using an Ethernet cable. No work is required for reconnecting Peripheral Cables onsite. Easier Adjustment for Temperature and Process Control! Ethernet Now, settings of parameters being monitored in the Trend View Window can be changed. Easier Memory Allocation for the EJ1 and PLCs Now, parameter selections and memory allocations for programless communications of the EJ1 and PLCs can be set in a table while viewing the PLC memory address. 8 9 Ver. 2. 1 Greater Beauty, Simpler, Upgrade planned for the near future and Better Multi-language Support Greater Beauty Make numeral displays and input objects more attractive, and increase or decrease the character string font size as desired. Use an attractive font for numerals that looks good on the display even when it is enlarged. And, smooth fonts can be used for alarms and character strings, and scalable fonts can be selected. In addition, worldwide support is provided with 42 languages, including Thai. Ordering Information Name Compatible OS Description Number of licenses (See note 1. ) 1 license DVD CD 3 licenses FA Integrated Tool Package CX-One Version 2. 1 Windows 98 SE, Me, NT 4. 0 (Service Pack 6a), 2000 (Service Pack 3 or higher), XP, or Vista Note supported. Media (See note 2. ) CD Model CXONE-AL01C-EV2 CXONE-AL01D-EV2 CXONE-AL03C-EV2 CXONE-AL03D-EV2 CXONE-AL10C-EV2 CXONE-AL10D-EV2 CXONE-AL30C-EV2 CXONE-AL30D-EV2 CXONE-AL50C-EV2 CXONE-AL50D-EV2 CXONE-LT01C-EV2 Greatly Enhanced Libraries of Beautiful Lamps and Switches Thai New 7-segment font A selection of over 800 beautiful objects is provided. Now, it's easier to allocate and change objects. CX-One is a comprehensive software package that integrates Support Software for OMRON PLCs and components. DVD CD 10 licenses DVD CD 30 licenses DVD Alarm display with new scalable Gothic font FA Integrated Tool Package CX-One Lite Version 2. 1 downloaded and updated from the Microsoft Download center of each region. CX-One Lite is a subset (see note 3) of the complete CX-One package that provides only the Support Software required for micro PLC applications. (See note 4. ) CD 50 licenses DVD 1 license CD New numeral font Note 1: Site licenses are available for users who will run CX-One on multiple computers. Note 2: When purchasing the DVD format, verify the computer model and DVD drive specifications before purchasing. Note 3: CX-One Lite provides the following Support Software: CX-Programmer Ver. 1. 7, Note 4: The following micro PLCs are supported by CX-One Lite: CP1@, CPM, and SRM1. Easier Design of Device Error Screens There is no need to create similar error screens, so you can easily create a device troubleshooter. Individual error display screens that were previously created for each error can now be integrated into one. It is possible to switch only the error details (text and screen) without ladder programming in conjunction with the alarm bit System Requirements Item Operating system (OS) (See notes 1. ) Microsoft Windows98 SE Microsoft Windows NT (Service Pack 6a) Requirement Microsoft Windows 2000 (Service Pack 3 or higher) or Microsoft Windows Me Microsoft Windows XP Microsoft Windows Vista (except 64-bit edition) (See note 4. ) IBM PC/AT or compatible with a processor recommended by Microsoft. [. . . ] Application software to set and control data for Inverters and Application software to create and debug function block programs for SYSMAC CS/CJ-series Loop Controllers (Loop Control Units/Boards, Process Control CPU Units, and Loop Control CPU Application software that automatically outputs screen data as project files for NS-series PTs from tag information in function block programs created with the CX-Process Tool. Application software to set and control parameters in components, such as Temperature Control Units. Application software for system setting and monitoring of SYSMAC CS/CJ-series FL-net Units. It helps to monitor the I/O status and to monitor/change specified present values within a PLC. [. . . ]