[. . . ] · Small distortions in the door and mechanical discrepancies can be absorbed in the allowable operating range of the magnetic actuator and switch. · Conforms to Category 3. Model Number Structure Model Number Legend Sensor Controller D40B-Type 1: Standard Sensor 2: Elongated Sensor 3: High-temperature Type Sensor 2. [. . . ] 14 · EN1088 conformance Internal Connection Diagram D40B-J1 2 1 A1 13 21 D40B-J2 2 1 A1 + 13 23 31 Control circuit NC MOS output Control circuit 3 4 A2 X1 X2 14 22 3 4 A2 - X1 X2 14 24 32 Note: 1. If a 100/230 VAC power supply is used, connect it to the A1 and A2 terminals. If a 24 VDC power supply is used, connect it to the + and - terminals. Do not connect the power supply to the A1 and A2 terminals. !WARNING Do not connect a 100/230 VAC power supply to the + and -terminals. Doing so may result in electric shock. Engineering Data Detection Ranges Standard Sensor Distance between the switch and actuator sensing surfaces Y (mm) OFF 14 12 10 8 6 4 ON 2 0 -6 -4 -2 2 0 -6 -4 -2 0 -6 Elongated Sensor Distance between the switch and actuator sensing surfaces Y (mm) OFF 14 12 10 8 6 ON 4 High-temperature Type Sensor Distance between the switch and actuator sensing surfaces Y (mm) 25 16 16 20 OFF 15 10 ON 5 0 2 4 6 0 2 4 6 -4 -2 0 2 4 6 Distance from the target mark on the switch X (mm) Distance from the target mark on the switch X (mm) Distance from the target mark on the switch X (mm) G-200 Safety Sensors / Components Dimensions Note: All units are in millimeters unless otherwise indicated. Sensor (Switch/Actuator) Standard Sensor Target mark Target mark 12 48 48 12 D40B-1B3 D40B-1B10 D40B-1D3 D40B-1D10 4. 8 25 4. 8 25 13 Two, 4. 2 dia. 7 (Switch) (Actuator) Elongated Sensor D40B-2B3 D40B-2B10 D40B-2D3 D40B-2D10 Target mark 19 4. 2 9 Target mark 4. 2 19 19 9 4. 3 19 9 82 68 54 82 73 64 4. 3 9 7 4. 5 4. 5 10 5 Cable diameter: 4. 2 dia. 10 5 5 5 7 (Switch) (Actuator) 33. 5 19. 5 4. 4 33. 5 19. 5 16 11. 5 8 4. 4 11. 5 High-temperature Type Sensor D40B-3D5C D40B-3E5C Target mark Target mark 16 8 62 78. 5 62 78. 5 11. 5 8 11. 5 4. 4 Note: A cable with connectors is included. 11. 5 10. 5 11 11 10. 5 (Switch) (Actuator) F3SL G-201 D40B Controller 1-pole Controller D40B-J1 22. 5 99 3 1 2 A1 4 A2 Terminal Arrangement POWER (Green) 82 75 OUTPUT (Green) X1 21 13 X2 22 14 2-pole Controller D40B-J2 Terminal Arrangement 45. 5 120 A1 + X1 2 1 13 23 31 POWER (Green) 73 OUTPUT (Green) A2 - X2 3 4 14 24 32 Application Examples Wiring Example for 1 Sensor and 2 Contactors (with D40B-J1): Auto-reset The configuration in this example is for auto-reset and contactor monitoring. Fuse Blue* Actuator Guard door Switch Operation Flowchart Switch: NO contact KM1 Switch: NC contact D40B-J1 safety output 3 4 A2 X1 X2 14 KM2 KM1, KM2: NC contact KM1 KM1, KM2: NO contact KM2 KM1 KM2 See Manual Start on page 9. Yellow* 2 1 A1 D40B-J1 Controller 13 Green* Red* M Note: The circuit in this example is equivalent to a Category 3 circuit. Refer to Sensor and Controller Connection Examples on page 10. G-202 Safety Sensors / Components Wiring Example for 1 Sensor and 2 Contactors (with D40B-J2): Auto-reset The configuration in this example is for auto-reset and contactor monitoring. Fuse Actuator Blue* Switch Yellow* 2 1 A1 + D40B-J2 Controller 3 4 A2 - X1 X2 14 24 32 13 23 31 KM1 Switch: NC contact KM2 D40B-J2 safety output KM1, KM2: NC contact KM2 KM1 KM2 KM1, KM2: NO contact See Manual Start on page 9. Guard door Operation Flowchart Switch: NO contact Green* KM1 Red* M Note: The circuit in this example is equivalent to a Category 3 circuit. Refer to Sensor and Controller Connection Examples on page 10. Wiring Example for 3 Sensors and 2 Contactors (with D40B-J2): Auto-reset The configuration in this example is for auto-reset and contactor monitoring. Fuse Actuator 1 Switch 1 Blue Yellow Green Red Blue* Yellow* Guard door 2 1 A1 + 13 23 31 Operation Flowchart Switch: NO contact KM1 Switch: NC contact Actuator 2 Switch 2 Blue Yellow Green Red Guard door D40B-J2 Controller 3 4 A2 - X1 X2 14 24 32 KM2 D40B-J2 safety output KM1, KM2: NC contact KM1, KM2: NO contact Actuator 3 Switch 3 Blue Yellow Green Red KM1 Guard door Green* Red* KM2 KM1 KM2 See Manual Start below. M Note 1: The circuit in this example is equivalent to a Category 3 circuit. Note 2: If two or more Sensors are connected to one Controller, all of the guard doors must open and close independently. If two or more doors open and close at the same time, it is possible that a fault may not be detected. Refer to Sensor and Controller Connection Examples on page 10. Manual Start If manual start is required, insert start switch S1 between X1 and X2 as shown below. Monitored start is not possible. X1 X2 KM1 Start switch S1 KM2 Start switch S1 D40B-J1 safety output KM1, KM2: NC contact KM1, KM2: NO contact Operation Flowchart Switch: NO contact Switch: NC contact F3SL G-203 D40B Sensor and Controller Connection Examples Connection between Standard or Elongated Sensor and 1-pole Controller Yellow D40B-1 Actuator 3 2 A1 4 A2 Connection between Standard or Elongated Sensor and 2-pole Controller Blue Yellow Switch A1 + X1 2 1 13 23 31 White* Black* * Auxiliary output D40B-1D@ (Standard models) and D40B-2D@ (Elongated models) only Blue Red 1 White* Black* * Auxiliary output D40B-1D@ (Standard models) and D40B-2D@ (Elongated models) only Red Green A2 - X2 3 4 14 24 32 X1 21 13 X2 22 14 D40B-J2 D40B-J1 Connection between High-temperature Type Sensor and 1-pole Controller Yellow Gray D40B-3@5C Actuator Switch 3 2 A1 4 A2 Connection between High-temperature Type Sensor and 2-pole Controller Blue Yellow D40B-3@5C Actuator Switch White* Black* Green * Auxiliary output Blue Red 1 A1 + X1 2 1 13 23 31 White* Black* Green Red Gray A2 - X2 3 4 14 24 32 * Auxiliary output X1 21 13 X2 22 14 D40B-J2 D40B-J1 G-204 Safety Sensors / Components Safety Precautions !WARNING Be sure to turn OFF the power before performing wiring. Do not allow the actuator to come close to the switch with the door open. Doing so may cause machinery to start operating and may result in injury. Mutual Interference If the switch and actuator are mounted in parallel, be sure to separate them by at least 25 mm, as shown below. 25 mm min. [. . . ] · Locations subject to static electricity or other forms of noise. · Locations close to power supply lines. Wiring Perform wiring using wire with the following dimensions. Stranded wire: 2. 5 mm2 Solid wire: 4. 0 mm2 Tighten the terminal screws with the specified torque. [. . . ]