[. . . ] Color sensor (LED type)
E3MC
E3MC
RGB Color Sensor Discriminates Delicate Differences in Color.
Features Double Indication ensuring high visibilty.
· Conformity with the registered colors can be monitored at eight levels. (Detection level indicators) · Allows fine adjustment between fine or rough discrimination while monitoring the measured results. · Wide temperature range from -20°C to 55°C and excellent detection stability.
Maintenance-free LED Light Source
Incorporates RGB LED light sources with a long service life more than several tens of thousand hours. Great maintenance-cost saver ensuring high performance (Halogen lamps used as light sources must be replaced or readjusted every nine months or so. )
Stable and Powerful Detection for Inline Use
Stable detection is assured with a threshold of ±10 mm for built-in amplifier type and ±4 mm for optical fiber type. [. . . ] (For conformity output setting) Set the threshold to a higher level for highly-precise color discrimination or to a lower level to allow margins for discriminated colors (ignore minor tint differences, dirt retention or like).
Detection Level
Tolerance Operation indicator: ON Control output: ON Operation indicator: OFF Control output: OFF
Threshold value
Threshold value
Detection level
1 2 3 BANK 4
LEVEL THRESHOLD
TEACH
SELECT
TEACH
ADJ
RUN
Make measurement in the RUN mode. The registered color can be selected with bank selection input.
A-154
Standard Photoelectric Sensors
4 output Models (E3MC-MA##/E3MC-MX##/E3MC-MY##)
1. Channel Selection
OUTPUT
1 2 CH- 3 OUT 4
LEVEL THRESHOLD
BLIP (2)
TEACH
(1)SELECT
ADJ RUN
TEACH
(1)
Set the Mode Selector to the ing the SELECT button.
TEACH
mode and then select the channel usOK
OUTPUT
2. Color Registration
OUTPUT OUTPUT
1 2 3 BANK 4
LEVEL THRESHOLD
Sensor Sensor
1 2 CH- 3 CHOUT 4 OUT
1 2 3 LEVEL 4 LEVEL THRESHOLD THRESHOLD
BLIP BLIP
If color registration has not been completed, all Not red threshold indicators Good (red) flicker.
TEACH
SELECT
TEACH
ADJ
RUN
TEACH TEACH
SELECT SELECT
Registered object Registered object
TEACH TEACH
ADJ ADJ RUN RUN
All detection level indicators (green) turn ON. The threshold is set to 4.
Locate the registered object at the detection point and press the TEACH button.
3. Threshold Adjustment (If Required)
OUTPUT
Sensor
1 2 CH- 3 OUT 4
LEVEL THRESHOLD
BLIP
TEACH
SELECT
Detection Level and Tolerance As the detected color becomes closer to the registered color (similar colors), the number of lit detection level indicators (green) increase. The control output will turn ON if the detection level (green) exceeds the threshold level (red) and turn OFF if the detection level does not exceed the threshold level. (For conformity output setting) Set the threshold to a higher level for highly-precise color discrimination or to a lower level to allow margins for discriminated colors (ignore minor tint differences, dirt retention or like).
Detection Level
Sensing object
TEACH
ADJ
RUN
ADJ
Tolerance Operation indicator: ON Control output: ON Operation indicator: OFF Control output: OFF
(Adjustment can be made without a sensing object) The bank selected in the ADJ mode or TEACH mode will become the bank for the RUN mode.
Threshold value
Threshold value
Detection level
E3MC
A-155
E3MC
peration
OUTPUT
For indicating detection level and threshold value for other channels
LEVEL THRESHOLD
1 2 CH- 3 OUT 4
Press the SELECT button. For checking which channel is indicated
OUTPUT
OUTPUT
TEACH
SELECT
TEACH
ADJ
RUN
1 2 CH- 3 OUT 4
LEVEL THRESHOLD
BLIP
1 2 CH- 3 OUT 4
LEVEL THRESHOLD
BLIP
Detection is made in the RUN mode. The output ON/OFF status of each channel is displayed on the channel indicators. Double-displayed channels can be checked and selected by pressing the button.
TEACH
SELECT
TEACH
SELECT
Press the TEACH button
TEACH
ADJ
RUN
TEACH
ADJ
RUN
Displays the channel the detection level of which is currently indicated in (CH-OUT). (For three seconds)
Displays the selected channel in (CHOUT) (for three seconds) and indicates the detection level and threshold value of the selected channel.
Registered Color Selection (Bank Selection Input)
1-output Models Only In the RUN mode, bank selection can be made externally with the bank selection input 1 (yellow) and input 2 (green). The selected bank is indicated by the bank selection indicator.
NPN (E3MC-A11/-X11/-Y11) Bank 1 2 3 4 Input 1 OPEN GND OPEN GND Input 2 OPEN OPEN GND GND PNP (E3MC-A41/-X41/-Y41) Bank 1 2 3 4 Input 1 OPEN Vcc OPEN Vcc Input 2 OPEN OPEN Vcc Vcc
External synchronous input function
The measurement results will be directly output to the control output if the input from the external synchronous input terminal (pink) is set to OFF. The output will hold the previous status if the input of the external synchronous input terminal is set to ON. As for the 4-output models, this function applies to the output of all the channels.
Sensing object ON Discrimination OFF result ON External synchronous input Control output Output on hold OFF ON OFF This status can be on hold by an external synchronous input. Output on hold Same color Different color Same color Same color
This status can be on hold so that unwanted color objects can be ignored while they are passing the sensing range.
A-156
Standard Photoelectric Sensors
Remote teaching (remote control function)
Mode Setting When using remote teaching (remote control function), you must set the Sensor to mode B. Setting Method Apply power to the Sensor while pressing the SELECT DOWN button and TEACH button at the same time.
TEACH SELECT
The following is an example of ladder programming.
00000 00100 TIM000 00100 END TIM000 set value No. 1: 0003 No. 2: 0006 No. 3: 0009 No. 4: 00012 No. 5: 00015 Input: 00000 Output: 00100 Others: Work bits
TIM000 #XXXX
Checking Method Whether the E3MC is operating in mode A or B can be checked with the operation indicator after mode setting (indicated for 3 s) or in the TEACH mode.
Mode A: Operation indicator is OFF.
OUTPUT
The following is an example of a timing chart of teaching after bank selection.
Input detection 1. 5s Remote control input 0. 3s ON OFF Operation in bank 2. specified Teaching.
Input detection
An interval of 0. 6 min.
1. 5s
1 2 CH- 3 OUT 4
Mode B: Operation indicator is ON.
LEVEL THRESHOLD
Sensing restarts. 0. 3s
OUTPUT
1 2 CH- 3 OUT 4
Answerback output
LEVEL THRESHOLD
in bank 1. 0. 3s 0. 5s
Answer-back output with normal signal reception.
Answer-back output with teaching OK. The current mode selected does not change after the Sensor is turned OFF. The remote control function is available in the RUN mode or ADJ mode only. [. . . ] Insert the Fiber Unit further unit it comes in contact with the innermost end. Sensor installation Tighten the Fiber Unit with a screwdriver to a torque of 0. 2 Nm. Fibers Among the recommended fibers, the E32-CC200 and E32-D32L have white or dotted yellow lines on the fiber to be inserted into the emitter. When using the E3MC-(M)Y##, insert the fiber with the line into the emitter section at the bottom of the amp.
Sensing dista
q = 20°
Sensing object
Recommended Fiber: Reflective Optical Fiber The following optical fibers are recommended for use with the E3MC-(M)Y##.
Model E32-DC200 E32-CC200*2 E32-D32L*3 Sensing distance*1 5 mm 5 mm 4. 5 mm
Common to Fiber Units Mounting
Tightening Force · The tightening force applied to the Fiber Unit should be as follows: (Screwed type) (Columnar type)
Mounting bracket Toothed washer Flat or pan head set screw (M3 max. )
E32-D11L 5 mm *1. [. . . ]