[. . . ] EXHAUSTO CDT control EFC18 is, like the EXHAUSTO CDT chimney fan, designed to be used with fire places, stoves and boilers for solid fuel. [. . . ] Always switch off the electricity supply before opening the control unit. The EFC18 is set initially so that the temperature sensor starts and stops the chimney fan at either 20°C, 40°C or 80°C. Press and hold the button in for 5 seconds and the figure displayed will change to 0, 1, 2 or 3. When the required number is displayed, hold down the button until a horizontal line appears ("--"). Setting options: 0 = Fitted without sensor 1 = Automatic start/stop of chimney fan, 20°C (open fire/closed stove/boiler) 2 = Automatic start/stop of chimney fan, 40°C (open fire/closed stove/boiler) 3 = Automatic start/stop of chimney fan, 80°C (alternative setting for closed stove/boiler: delayed start/rapid stop) The fire is lit and the chimney fan runs at full speed for 7 mins. The speed of the chimney fan can be changed at any time from 1 ­ 9 by holding down the button. When the sensor is active (red dot in display), the refuelling option can be activated by pressing the button briefly. Automatic stop When the temperature falls below 20°C, 40°C or 80°C depending on the setting, the 45 minutes post purge period will start. [. . . ] Tietgens Boulevard 41 DK-5220 Odense SØ DANMARK erklærer på eget ansvar, at følgende produkter: hereby declares that the following products: erklärt hierdurch auf eigene Verantwortung, daß folgende Produkte: déclare, sous sa propre responsabilité, que les produits suivants: erklærer på eget ansvar at følgende produkter: som er omfattet af denne erklæring, er i overensstemmelse med følgende standarder: were manufactured in conformity with the provisions of the following standards: die von dieser Erklärung umfaßt sind, den folgenden Normen: auxquels s'applique cette déclaration sont en conformité avec les normes ci-contre: som er omfattet av denne erklæring, er i samsvar med følgende standarder: i. [. . . ]