[. . . ] Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. Serial Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 1. Transfer Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 2. Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3. [. . . ] Acceptable Unacceptable [ACK] [CR] ""[CR]
6. 12.
VOLUME Command
Command Detail Response "C0A" [CR] Volume Down This command operates the same as VOLUME - button of remote control. Acceptable Unacceptable [ACK] [CR] ""[CR]
6. 13.
AUDIO MUTE ON Command
Command Detail "C0B" [CR] Sound Mute ON This command works the same as "MUTE" button of the remote control for Mute ON, but does not work for Mute OFF. Acceptable Unacceptable [ACK] [CR] ""[CR]
Response
6. 14.
AUDIO MUTE OFF Command
Command Detail "C0C" [CR] Sound Mute OFF. This command works the same as "MUTE" button of the remote control for Mute OFF, but does not work for Mute ON. Acceptable Unacceptable [ACK] [CR] ""[CR]
Response
6. 15. VIDEO MUTE ON Command
Command Detail "C0D"[CR] Video Mute ON. This command works the same as "NO SHOW" button of the remote control for No Show ON, but does not work for No Show OFF. Acceptable Unacceptable [ACK] [CR] ""[CR]
Response
11/23
PLC-XE50 Basic Serial Command Specifications
6. 16.
VIDEO MUTE OFF Command
Command Detail "C0E" [CR] Video Mute OFF. This command works the same as "NO SHOW" button of remote control for No Show OFF, but does not work for No Show ON. Acceptable Unacceptable [ACK] [CR] ""[CR]
Response
6. 17. Screen Normal size Command
Command Detail Response "C0F" [CR] Set screen size to Regular(4:3). Acceptable Unacceptable [ACK] [CR] ""[CR]
6. 18.
Screen Wide size Command
Command Detail Response "C10" [CR] Set screen size to Wide (16:9). Acceptable Unacceptable [ACK] [CR] ""[CR]
6. 19.
Image Standard Command
Command Detail Response "C11" [CR] Set Image to Standard mode. Acceptable Unacceptable [ACK] [CR] ""[CR]
6. 20.
Image Real Command
Command Detail Response "C12" [CR] Set Image to Real mode. Image Cinema Command
Command Detail Response "C13" [CR] Set Image to Cinema mode. Acceptable Unacceptable [ACK] [CR] ""[CR]
12/23
PLC-XE50 Basic Serial Command Specifications
6. 22. Image 1 Command
Command Detail Response "C14" [CR] Set image to Image 1 mode. Acceptable Unacceptable [ACK] [CR] ""[CR]
6. 23.
Image 2 Command
Command Detail Response "C15" [CR] Set image to Image 2 mode. Acceptable Unacceptable [ACK] [CR] ""[CR]
6. 24.
Image 3 Command
Command Detail Response "C16" [CR] Set image to Image 3 mode. Acceptable Unacceptable [ACK] [CR] ""[CR]
6. 25.
Image 4 Command
Command Detail Response "C17" [CR] Set image to Image 4 mode. Acceptable Unacceptable [ACK] [CR] ""[CR]
6. 26.
Image Blackboard(Green) Command
Command Detail Response "C18" [CR] Set image to Blackboard (Green) mode. Image Dynamic Command
Command Detail Response "C19" [CR] Set image to Dynamic mode. [. . . ] "88"[CR]
Status : Coming back after temperature anomaly When the status moves to Standby after Cooling Down due to temperature anomaly, it returns "88" [CR]. This shows that the status turns to Standby because of abnormal temperature. When Power On is executed, the information of temperature anomaly is canceled and normal operation is executed.
21/23
PLC-XE50 Basic Serial Command Specifications
7. 3. 8. "24"[CR]
Status : Processing Power Save / Cooling Down Power management function in the Setting menu works and the status goes to Power Save / Cooling Down. [. . . ]