[. . . ] OPERATING AND INSTALLATION MANUAL
I)
CONDIZIONATORI D'ARIA E POMPA DI CALORE SINGLE SPLIT ON-OFF E DC INVERTER
EN) SINGLE SPLIT DC INVERTER AND ON-OFF AIR CONDITIONERS AND HEAT PUMP
Dear Customer, Thank you for having chosen a or , air conditioner, which is an innovative, high quality product designed to ensure your wellbeing. This instruction booklet contains important information and recommendations that we would ask you to comply with to obtain best results from your air conditioner. In line with the company's policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice.
CONTENTS
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conformity and range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety rules and recommendations for the installer . . . . . . 2 Safety rules and recommendations for the user. . . . . . . . . . . . . 2 Safety rules and prohibitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Names of the parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 USER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] - Press the TIMER ON button within 10 seconds to confirm otherwise the function will exit from time setting. Note: to cancel the function setting, press the TIMER ON button again. Automatic switching-off To set the automatic switching-off time, proceed as follows: - Press the TIMER OFF ( ) button. - Press the TIMER OFF button within 10 seconds to confirm, otherwise the function will exit from time setting. Note: to cancel the function setting, press the TIMER OFF button again.
ON OFF
USER
B-LOGIC B Logic INTELLIGENT REMOTE CONTROL
!
88:88 PM AM
ON TIMER OFF TIMER
F Logic F-LOGICREMOTE CONTROL INTELLIGENT
ON OFF
!
Note: it is also possible to set the appliance switching-on and switching-off time so as to define a specific duration of operation. Note: the appliance will start in the mode of operation that was selected before switching off.
SINGLE SPLIT
ENGLISH
9
FAN MODE
Fan mode Press the MODE button until the FAN ( ) symbol appears. Every time the FAN button , is pressed the speed changes in the following sequence: AUTO LOW MEDIUM HIGH. The remote control also stores the speed that was set in the previous mode of operation. In SMART mode , the air conditioner automatically chooses the fan speed and the mode of operation (COOLING or HEATING). Note: Once the fan speed has been set the indicator lights will start to blink from the lowest to the tallest at a speed that varies according to the set fan speed. See the table to the side for an example.
ON OFF
USER
INTELLIGENT REMOTE CONTROL
!
Indoor unit display
Blinking Slow Medium Fast Set speed Minimum fan speed Medium fan speed Maximum fan speed
DRY MODE
Dehumidifying mode Press the MODE button until the DRY symbol ( ) appears. The appliance activates according to the room and the set temperature: temperature, the compressor and the outdoor unit stop while the indoor unit fan operates at low speed. temperature, the appliance automatically passes to the dehumidifying function, activating the fan at low speed.
USER
INTELLIGENT REMOTE CONTROL
MODE
-
+
23 °C
ON
OFF
SMART MODE
Modalità automatica B Logic Remote Control (Fig. 1): To activate the SMART function, press the SMART button ( ) on the remote control. 2): To activate the SMART (automatic) mode of operation press the MODE button on the remote control until the symbol appears on the display. In the AUTO mode the fan speed and the temperature are set automatically according to the room temperature to ensure user comfort.
Room temperature between 22°C 22 ~ 24°C above 26°C Modr HEATING DRY COOLING
USER
12:38 AM
MODE
OFF TIMER
Fig. 2
MODE
-
MODE
+
-
+
ON
OFF
Note: after having stopped the SMART function, the air conditioner will start up with the settings of the previously selected modes.
10
ENGLISH
SINGLE SPLIT
SLEEP MODE
Night mode To activate the night function in the COOL, DRY and HEAT modes, press the SLEEP button. During operation in the night mode, the set temperature increases by 1 °C in the first hour of operation and by another 1 °C in the following hour, maintaining this increase of 2°C in the subsequent hours. Selecting the night function in the heating mode, the set temperature decreases by 1 °C in the first hour of operation and by another 1 °C in the following hour, maintaining this decrease of 2°C in the subsequent hours with the fan operating at minimum speed.
USER
INTELLIGENT REMOTE CONTROL
ON
OFF
!
NOTE: Under FAN and SMART modes, this function is not available.
I COMFORT FUNCTION
Press the I COMFORT ( ), )button and the symbol appears on the display. This function is used to obtain the required climate in the exact point where the remote control is located. The temperature of reference is that measured by the sensor in the remote control, bypassing the temperature sensor inside the air conditioner. If no signal is received from the remote control for 11 minutes, the unit will once again refer to its own internal sensor
USER
INTELLIGENT REMOTE CONTROL
ON
OFF
!
!
MODE
ROOM TEMPERATURE FUNCTION
Press the ROOM TEMPERATURE button (only on the F Logic remote control) for the various modes of measuring the temperature in the room where the appliance is installed. [. . . ] Ensure that the recommended space is left around the appliance.
16
ENGLISH
SINGLE SPLIT
BLEEDING
Humid air left inside the refrigerant circuit can cause compressor malfunction. After having connected the indoor and outdoor units, bleed the air and humidity from the refrigerant circuit using a vacuum pump. (4) Operate the vacuum pump for 10-15 minutes until an absolute vacuum of 10 mm Hg has been reached. (5) With the vacuum pump still in operation, close the low-pressure knob on the vacuum pump coupling. [. . . ]