[. . . ] If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
SET
SLEEP
LOCK
RESET
2
Operation
Base Operation
ON/OFF
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room Designated Timer Fan Operation temperature temperature mode speed mode
Above 23 C
SLEEP
Remote controller
FAN
MODE
SWING
POWER/SOFT
TIMER
emergency operation switch
CLOCK
P
o
LIGHT
26 C 23 C
o
o
i
No No
AUTO AUTO
COOL HEAT
SET
Below 23 C
LOCK RESET
o
It is impossible to change the settings of temp. [. . . ] Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.
Accessory Parts
Remote controller (1) Drain hose (1)
R-03 dry battery (2) Mounting plate (1)
Plastic cap (4) Ø4X25 Screw (4) Air purifying filter(Optional) (1)
Selection of Pipe
FOR 18K FOR 24K
Drawing for the installation of indoor units
The models adopt HFC free refrigerant R410A
Attention must be paid to the rising up of drain hose
more than 15 cm
Arrangement of piping directions Rear left
more than 10cm
Left
Rear right Right Below
more than 10cm
The distance between the indoor unit and the floor should be more than 2m. Please be subject to the actual product purchased, the above picture is just for your reference.
6
Indoor Unit Installation
Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed
1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail. Insert the drain hose into the dent of heat insulation materials of indoor unit. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
Indoor/outdoor electric cable Heat insulation material
Lid for right piping Lid for under piping pipe Fix with adhesive tape
Piping Pipe supporting plate
Lid for left piping Drain hose
B= Ø 70mm
Indoor/outdoor electric cable and drain hose must be bound with efrigerant piping by protecting tape.
[ Other direction piping ]
A=145mm
Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to theposition of wall hole. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially.
B= 70mm
30mm
Fixing the indoor unit body
A=150mm
35mm
When the mounting plate is fixed side bar and lintel
Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten the plate to the fixed mounting bar. Refer to the previous article, " When the mounting plate is first fixed ", for the position of wall hole.
Hang surely the unit body onto the upper notches of the mounting plate. In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly. mounting plate
Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 70 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation
Wall hole
Unloading of indoor unit body
When you unload the indoor unit, please use your hand to arise the body to leave agraffe, then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate.
Ø70mm
Indoor side
Outdoor side Thickness of wall
(Section of wall hole)
G Piping hole pipe
agraffe
mounting plate
Installation of the Indoor Unit Drawing of pipe
Connecting the indoor/outdoor Electric Cable Removing the wiring cover
Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws.
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
7
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop.
Correct
Incorrect
Lean
Damage of flare
Crack
Partial
Too outside
On Drainage
Please install the drain hose so as to be downward slope without fail. Please don't do the drainage as shown below.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover.
Less than 5cm It becomes The end is imm- It waves. [. . . ] 3. If the fuse of indoor unit on PC board is broken, please change it with the type of T. If the fuse of outdoor unit is broken, change it with the type of T. 25A/250V 4. After installation, the power plug should be easily reached.
In dry mode, fan speed can't be changed.
6. The appliance is not intended for use by young children or infirm persons without supervision. [. . . ]