[. . . ] 2 - Type and dimensional characteristics of the chimney flue to which the fireplace must beconnected. We strongly recommend that you take the time to thoroughly read and familiarize yourself with this manual in order to obtain maximum enjoyment and satisfaction from your DEVILLE fireplace. All local, national, and european regulations must be respected when using this appliance. the nonobservance of the assembly , installation and operating instructions shall engage the liability of the individual(s) concerned. [. . . ] 7 - Walls in the vicinity of the appliance Install the fireplace ready to set up at a minimum 300 mm distance from the side walls of the accommodation and from any combustible material. In order to protect the floor from heat radiation and possible falling combustible, install the unit on reflective metal shielding (or on a tiled floor) which covers the entire surface underneath and in front of the unit. The apparatus should be installed on a floor with sufficient bearing capacity. If an existing building does not meet this precondition, proper measures should be taken (for example, the installation of a load spreading plate) to enable the floor to bear the apparatus. 6), it is necessary to respect a perimeter in noncombustible materials around the joining conduit (Fig. Fix the wall screen, it is imperative to pierce the first range of holes 32 mm from the ceiling (Fig. Install the upper device to hide the pipe on the wall screen and fix it. To make the installation of the appliance easier, it's necessary to remove the décor façade by lifting it up and then pulling it forward. Remove the device to hide the pipe by sliding it forward and lifting it up (Fig. Dismantle the screen of the wall of the upper device to hide the pipe (2 screws). The ensemble to hide the pipe is modular; it allows you to set up from 2. 2 installation configurations are possible : · CONNECTION ON TOP (FIG 5 AND FIG 14) Dismantle the ceiling screen from the wall screen and remove the circular pre-cut (Fig. It is imperative to pierce the first row of holes 32 mm from the ceiling (Fig. Install the joining conduit with the ceiling screen and fix the latter (Fig. Install the upper device to hide the pipe on the wall screen and fix it. 1), burn a moderate fire for the first few hours, by limiting the load (one 15 cm log) and set the air intake control lever in the middle position (Fig. 15) : this enables the temperature of all chimney elements to rise progressively and ensures normal fireplace dilation. Do not connect the appliance to a conduit linked to several appliances. We recommend that you use very dry wood with a maximum moisture content of 20%, or wood that has been stored under shelter for 2 years after being cut in order to obtain the best yield and to prevent the accumulation of creosote in the flue and on the glass. ) which leads to more frequent maintenance of the fireplace and chimney flue. Place some crumpled paper and very dry twigs on the grate followed by branches of larger diameter (approximately 3 to 5 cm). Light the paper and close the door (or leave the door slightly open to accelerate the blaze). [. . . ] Loosen door closure : (Fig 19) Alternately loosen screw (2) and tighten screw (1). TERMS AND CONDITIONS Apart from the legal warranty, particularly for latent defects, Deville guarantees to deliver the furniture in case of obvious defects or non-conformity to the ordered furniture. Without prejudice to the provisions that are to be taken concerning the carrier, claims on delivery of furniture concerning the obvious defects or the non conformity, must be issued by the Buyer in writing a registered letter with confirmation of receipt to Deville company with in 5 days after noticing the defect. It is up to the Buyer to prove the reality of the noticed defects and irregularities. [. . . ]