[. . . ] that Cords the lid
Connecting The motor operation
to the Mains Supply of from the prodovit mains is designed of for
in the
be stored properly.
a way
50 cycles,
between able check according the
110/125 V, 110/125 V, 60 cycles or 220 V, 50 cyA. motor to be used for voltages is availTherefore the supply also Note must be connected current. A universal as well.
110-240 V and 50-60 cycles
This model and to the prevailing type the
voltage
before
the data chamber
connecting panel lid.
projector.
on the inside
of the magazine at the
The projection-lamp same voltage.
must also be rated
Connecting line
the Remote Control Cable control cable with the red on the opposite the red dot
Plug in the remote on the plug back of the body. 4
Push the plug
home firmly.
~
. ~
10422-31 ~
Operation
Switching
On and 011 both buttons symbol control the projector only is the By The
By depressing switched button doing with
on. [. . . ] The projection ning sible af a show image lens to is focused obtain at the beginposthe sharpest
levelling. You image also can helps adjust to the level height of milled the projected This on uneven proby turning the two screws.
on the screen.
the projector more
surtaces. Do not tilt vided
up the projector
than
for by the levelling
adjustment.
8
Operating the slide changer switching off the projector. turning of the arrow the the milled
by hand alter
transport changer button manu-
magazine knob
in the direction
moves the slide
9
The motor and gears need no maintenance, be oiled.
of
and
the pradovit must never
Maintenance
Opening
the Lamp House.
Disconnect the projector before opening the lamp house!The lamp house cover will swing open when you gently lift the spring catch inside the magazine chamber. To close, push down the lamp house cover from the outside until the spring catch engages again.
10
. , ~.
. .
10433·31
Taking
off the side panel.
Inserting
and changing
the projection
lamp.
The side panel which carries the name "prodovit" can be pulled upwards after first maving the twa holding springs ta the side. Before doing so, the screw which holds the springs, must be slightly losened and depressed.
First lift out the lamp chimney. The prajection lomp 300 or 500 watt with pin-type-cap G 17 q far pradovit-f is pushed in firmly. The pins in the cap of the lamp must be guided exactly into the cutouts of the socket. The low voltage lamp 12 V/100 watt for the pradovit-n has twa guide pins at the lamp cap. Push the low voltage lamp in the cutouts af the lamp socket and turn it to the right until both pins engage in the bayonet fitting. When taking out the lamp, push it down first and turn to the left to disengage the bayonet fitting.
11
10430-31
Centering the Projection Lamp. For centering pinhole a white obtained shown slide piece of the reflected jection-lens. in front centering is observed 'can insert the The above the ideal double the low reflected illustration focusing image voltage image of the image represents With the to the obove With it is aimed into the film image of po per the The filament by holding of the proeasily screw be as for the pradovit-f. field for
of the filament lamp
get as a homogeneous
os possible. the pradovit-n
The best position by turning
must be seen exactly
in the illustrotion.
the lamp filoment.
12
Cleaning. words are projection All coated opening the of For (not the lamp house you with can easily as the heat prosable the the other lenses, This withdraw holder the lamp aspheric the chimney condenser, especially only a soft, cloth). appreciably increases trast of the projected LEITZ stands faces are dirt. still hard coating up to normal as any sensitive the brilliance and conimage. Although the is highly resistant the glass optical marks Remove with of course, and any and surother major fluffcleaning,
as well
movable use
condenser
cleaning,
high-quality to finger
glass
lens,
an antistatic lens simply exposed with lens
To clean
So avoid
touching
any glass
and mirror a soft,
surface
with your fingers. [. . . ] voltage, a 230 volt
above If your lamp
and AC
below supply
the normal carries
supply
The pradovit-f and cap. disk 500 watt
an overone, or that the
then you should in place even new a cases
choose, a lamp lamp,
for instance, for 240 volts. to the aca 11O-volt it otherwise or apprecipremature causes; useless
In connectian for the lamp
the 500 watt as well code is fitted with the
of the 220-volt check
2nd heat absorbing 37915 C is essential. The guide immediately guide lamp disk and disk in has lamps and
as the guide number in the milled housing This of the on
in extreme Before voltage tual lamp worse will
housing filter down into of the
fitting marked must still not out very easily for
on it corresponds For instance, supply, to knocks whether any are of be connected immediately.
absorbing
mains
voltage.
longitudinal
cutouts
of the condensor-
to a 125-volt Projection
tightened is fitted front no
a 220 volt sensitive establish is due to
burn tilting can
lamps
the lamp the ventilation
are also able ers lamp claims
reflector. [. . . ]