[. . . ] Operating instructions
Vacuum cleaner S 4000
To prevent accidents and machine damage, read these instructions before installation and use.
UV
M. -Nr. 32 Replacing the "ActiveAirClean Plus" filter and the "Active HEPA Plus" filter . 44
3
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
The manufacturer cannot be held responsible for any damage caused by non-compliance of these Important Safety Instructions.
WARNINGTo reduce the risk of fire, electric shock or injury:
Before using
Check the voltage rating of the vacuum cleaner before connecting the power cord to an electrical outlet. Your power source should correspond with the voltage rating plate located on the underside of the vacuum. [. . . ] Ces limites sont destinées à apporter une protection raisonnable à tout brouillage préjudiciable lorsque l'équipement fonctionne dans une résidence. Cet équipement génère, utilise et peut irradier des fréquences radio si l'installation et l'utilisation ne sont pas conformes aux instructions, et peut provoquer un brouillage préjudiciable aux communications radio. Il n'y a cependant aucune garantie que l'interférence ne puisse pas avoir lieu dans une installation particulière. Si cet équipement provoque un brouillage préjudiciable lors des réceptions radio et télé, en allumant ou en éteignant l'appareil, l'utilisateur peut prendre l'une ou l'autre de ces mesures : Ré-orienter ou changer l'antenne de place Augmenter l'espace entre l'équipement et le récepteur. Brancher l'équipement dans une prise de courant différente de celle du récepteur. Consulter le détaillant ou un technicien radio/TV expérimenté si nécessaire
, Avertissement: Les changements ou les modifications de cette unité non-approuvés expressément par la partie responsable de la conformité peut annuler le droit de l'utilisateur à faire fonctionner l'équipement.
VEUILLEZ CONSERVER CES INSTRUCTIONS
13
Guide to the machine
Some models come standard with one of the following accessories, which are not shown in this figure. Turbobrush Rechargeable battery brush ACCU NOVA A separate Operating manual of the respective accessory is supplied with the vacuum.
14
Guide to the machine
a Handpiece (some models may include an air inlet valve) * b Suction power buttons + / * c Standby switch * d LED * e Locking button f Accessory clip * g Telescopic wand release button * h Dust compartment lid release i Telescopic wand * j Dust bag k Carrying handle l Floor tool * m Transport/storage holder n Dust compartment filter (motor protection) o Exhaust filter * p Suction power selector * q Standby indicator * r Thermo indicator , * s Exhaust filter change indicator (Reset button) * t Power cord with plug u Cord rewind switch v Park-System w On / Off switch x Dustbag change indicator y Elbow z Suction hose The features marked * may vary or not be available depending on your model.
15
Before using the vacuum cleaner
Attaching the suction hose
^ Insert the elbow into the suction socket until it clicks. Use the inlet guides to direct insertion.
Removing the suction hose
^ Press the release buttons at the sides of the elbow and lift the hose from the socket.
Connecting the handpiece and telescopic wand
^ Insert the handpiece into the telescopic wand until it clicks. ^ To release the handpiece from the telescopic wand press the locking button (see arrow) and pull the handpiece away from the telescopic wand.
16
Before using the vacuum cleaner
Depending on your model, the vacuum will included one of the following telescopic wands: Telescopic wand XXL telescopic wand
Adjusting the telescopic wand
One section of the telescopic wand is inside the other and can be adjusted for comfortable vacuuming. ^ Press the telescopic wand release button (see arrow) to release the tubes and adjust to the desired height.
Adjusting the XXL telescopic wand
This telescopic wand consists of three sections which are height-adjustable. Press the release button if you want to retract the lower section again. ^ Press the adjustment button, b, to release the tubes and adjust to the desired height.
17
Before using the vacuum cleaner
Attaching the floor brush
^ Insert the wand into the floor brush and twist until it locks with a click. ^ To release the floor brush from the telescopic wand, press the locking button (see arrow) and pull the wand out of the floor brush. The floor brush is suitable for cleaning carpets, rugs, and hard surfaces. For flooring susceptible to scratches, use one of the special Miele floor brushes (see "Optional accessories"). To clean carpets and area rugs: ^ Press the foot switch marked ö. Turbobrush / Rechargeable battery brush ACCU NOVA Some models have optional floor tools as accessories. Please refer to the separate operating instructions supplied with these brushes for instruction on use and maintenance.
18
Using the included accessories
The following accessories are included: a Crevice nozzle b Dusting brush (depending on model) c Upholstery tool d Accessory clip for the respective included accessories e Filter frame The filter frame is supplied only with those models which are fitted with an "ActiveAirClean Plus" or "Active HEPA Plus" exhaust filter as standard. The filter frame is required to replace one of these filters with a "SUPER air clean" filter (see "Maintenance and care Replacing one type of filter with another").
Accessory clip
^ The accessory clip can be attached to the handpiece.
Standard floor brush
The standard floor brush can be used for normal cleaning of carpets, rugs, hard surfaces, carpeted stairs, etc.
19
Using the included accessories
Crevice nozzle
For cleaning in folds, crevices and corners.
Upholstery nozzle
For cleaning upholstery, mattresses, cushions, curtains, covers, etc.
Dust brush with natural bristles
For cleaning moldings, decorative or carved items, etc. The head of the dusting brush can be swivelled to attain the best cleaning position. For dusting particularly delicate objects.
20
Operation
Power cord
, Unwind the cable completely to aid the vacuum in dissipating heat.
Unwinding ^ Hold the plug and pull the power cord out to the required length (maximum 18 ft / 5. 5 m).
, To reduce the risk of electric shock, the vacuum has a polarized plug (one blade is wider than the other). Danger of overheating and damage.
Rewinding ^ Unplug the vacuum from the outlet. [. . . ] They will damage the surface.
Dust compartment The dust compartment can, if necessary, be cleaned using a dry cloth, dusting brush or a second vacuum to suck out any dust. Monitor the change dustbag indicator and inspect all filters regularly. Clean or replace them when necessary according to these Operating Instructions.
, Do not submerge the vacuum in water!If moisture gets into the appliance there is the risk of an electric shock.
37
Frequently asked questions
Some models have a warning light , which comes on to indicate overheating. [. . . ]