[. . . ] RCS-SH80UA. WL (Wireless type: for X and T type indoor units) RCS-BH80UA. WL (Wireless type: for U type indoor unit) (Wireless type: for K type indoor unit ) RCS-SH1UA (System Remote Controller) 3. SHA-KC64UG Indoor Units
Wall-Mounted type KH2672R KH3072R KH3672R KHH2672R XH3672R XH4272R TH3672R TH4272R THH2672R THH3672R UH3672R 4-Way Air Discharge Semi-Concealed type XH2672R Ceiling-Mounted type TH2672R Concealed-Duct type UH2672R
1 2 3
Split System Air Conditioner
·
INSTRUCTION MANUAL
85464189788001 ©SANYO 2006
SANYO Electric Co. , Ltd.
Gunma, Japan
Save These Instructions!
RCS-SH80UG
Wall-Mounted type KH2672R KH3072R KH3672R KHH2672R XH3672R XH4272R TH3672R TH4272R THH2672R THH3672R UH3672R 4-Way Air Discharge Semi-Concealed type XH2672R Ceiling-Mounted type TH2672R Concealed-Duct type UH2672R
1
Split System Air Conditioner
·
INSTRUCTION MANUAL
Contents
Page Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Alert Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Otherwise there is a risk of suffocation in an extreme case.
2
· Do not turn the air conditioner on and off from the power mains switch. · Do not stick anything into the air outlet of the outdoor unit. · Do not cool or heat the room too much if babies or invalids are present.
2-3
Unit Display and Operation Controller for K, X, and T Types
Remote control receiver
OPERATION lamp
TIMER lamp
STANDBY lamp
2
NORM. STDBY TIMER
TIMER lamp STAND BY lamp
OPERATION lamp TIMER lamp STANDBY lamp
This lamp lights when the appliance is turned on. When the unit is in the heating standby condition, the STANDBY lamp lights. If the unit is used for cooling only, the STANDBY lamp will not illuminate. This section picks up infrared signals from the wireless remote controller (transmitter). You can operate this air conditioner using the operation controller without the wireless remote controller.
Remote control receiver Operation controller (housed inside)
2-4
Unit Display and Operation Controller for K, X, and T Types (continued)
To access the operation controller: Press on the two latches of the air intake grille with your thumb in the direction of the arrow to open the grille. The Operation Controller is located in front of the electrical component box.
SERVICING switches
ADDRESS switch
Switch
SWEEP button
ON/OFF operation button
ON/OFF operation button SWEEP button Switch ADDRESS switch
This button is for turning the air conditioner on and off (automatically setting cooling or heating operation). Use this button to make the airflow direction sweep up and down automatically. When operating the air conditioner by using the wireless remote controller, be sure to match the number on this switch with the number set on the wireless remote controller. These switches are used only when servicing the air conditioner.
SERVICING switches
Do not use these SERVICING switches for normal operation.
2
Turning off the ON/OFF operation button does not disconnect the power. position Normal position OFF position TEST position Select this position when the unit will not be used for a long period of time.
OFF
NORM. This position should not be selected under normal conditions.
OPER. STDBY TIMER
2-5
Operation Controller with Receiver (Separated from Indoor Unit) for U Type
A: Operation controller
B: Remote control receiver C: ON/OFF operation button D: SWEEP button E: SERVICING switches F: Switch G: ADDRESS switch H: OPERATION lamp I: TIMER lamp J: STANDBY lamp K: FILTER lamp
A: Operation controller (separated from indoor unit) B: Remote control receiver C: ON/OFF operation button
You can operate this air conditioner using the operation controller without the wireless remote controller. This section picks up infrared signals from the wireless remote controller (transmitter). This button is for turning the air conditioner on and off (automatically setting cooling or heating operation). Use this button to make the airflow direction sweep up and down automatically. These switches are used only when servicing the air conditioner.
2
D: SWEEP button E: SERVICING switches
Do not use these SERVICING switches for normal operation.
F: Switch G: ADDRESS switch
Usually set this switch in to the NORMAL position. When operating the air conditioner by using the wireless remote controller, be sure to match the number on this switch with the number set on the wireless remote controller. When the unit is in the heating standby condition, the STANDBY lamp lights. If the unit is used for cooling only, the STANDBY lamp will not illuminate. [. . . ] 2: Individual ON/OFF, MODE and Temperature setting operation is inhibited. (Individual operation)
M: SET button
NOTE NOTE
N: CL button
This button is used for setting indoor unit's address when installing the air conditioner. The air conditioner has the timer for the filter and informs you when the filter needs cleaning. If is displayed when pressing the ventilation button, no fans are installed.
O: VENTILATION button
3
3-6
I Display
H F B G E K D I A C J
Description A: When the unit is in the heating standby mode, the indicator appears. [. . . ]