[. . . ] To prevent appliance damage, the cabinetry and venting hood should be installed first. The countertop must be bonded with heat resistant (212 °F/100 °C) adhesive to prevent distortion. The cooktops should only be installed with the required safety distances shown. [. . . ] Never leave the grill unattended when in use.
If more than one appliance is installed beneath a hood and they have different mimimum safety distances, the greater distance should be followed.
Keep this instruction book in a safe place and pass it on to any future owner.
6
Appliance dimensions
KM 400 / KM 408-1
a Clamps b Please allow an additional 3/4" (18 mm) depth below the cooktop for clearance of the power cord.
7
Appliance dimensions
KM 402 / KM 403
a Clamps
8
Appliance dimensions
KM 410 / KM 411
a Clamps
9
Installation
Cutting out the countertop
Installing one or multiple appliances: Cut out the countertop using the dimensions listed in the following table. Number of cooktops 1 2 3 4 5 All Miele combisets have the same length and width. Make sure that there is enough room beneath the countertop to allow for the depth of the various appliances. When installing a KM 402 / KM 403 or KM 410 / KM 411 remember to allow clearance for the drain valve that will be located in the cabinet beneath the appliances. 6 7 Cut out width Dimension "B" 10 13/16" 22 1/8" 33 1/2" 44 13/16 56 1/8" 67 1/2" 78 13/16" (274 mm) (562 mm) (850 mm) (1138 mm) (1426 mm) (1714 mm) (2002 mm)
The tolerance for each dimension is 1 /16" (1 mm).
The following safety distances must be maintained: Between the cooktop and rear wall: 2" (50 mm). Between the cooktop and side wall or cabinet: KM 400 = 2" (50 mm) KM 402 / 403= 2" (50 mm) KM 408-1 = 2" (50 mm) KM 410 / 411 =10" (250 mm Refer to section "Important Safety Instructions" for further information.
When installing more than one combiset cooktop, a support bar must be installed between the appliances. Install the support bars as shown on the following page before setting the appliances into the countertop.
10
Installation
Laying out the support bars and clamps
a Clamps b Support bars This illustration shows the layout for 3 combisets, their respective support bars, b, and the 14 spring clamps, a, required for correct installation. If more than 3 combisets are being installed, add an additional 11 3/8" (288 mm) to the overall width of the cut out for each extra combiset, or use the table on the preceeding page.
c Slight gap between support bar and countertop.
11
Installation
Securing the support bars Securing the spring clamps
d
c
Wood or Corian countertops ^ Arrange the bars, b, as shown in the illustration ^ Drill 1/16" ( 1. 5 mm) pilot holes through the brackets and secure them using the supplied screws. ^ Fill the gap, c, between the bars and the countertop using the supplied silicon sealant. Wood or Corian countertops ^ Place the spring clamps, a, as shown in the illustration. ^ Drill two 1/16" (1. 5 mm) pilot holes for each clamp and secure using the supplied screws.
Granite countertops For granite countertops, the support bars, b, can be secured using doublesided construction tape. Do not allow the bars to "float", they must be securely fastened. Fill the gap, c, between the bars and the countertop using the supplied silicon sealant. The screws are not necessary for granite countertops.
Granite countertops For granite countertops, the spring clamps can be secured using doublesided construction adhesive. Do not allow the spring clamps to "float", they must be securely fastened. The screws are not necessary for granite countertops.
12
Installation
Locking the appliance into place
Make sure the cooktops are aligned correctly before setting them into the countertop. [. . . ] The manufacturer cannot be held responsible for damages caused by the lack, or inadequacy of, an effective grounding system. All electrical work should be performed by a qualified electrician in accordance with local codes and with the National Electrical code ANSI / NFPA No. 70-1481 for USA Power supply: 240 V, 60 Hz, 15 A fuse rating or 208 V, 60 Hz, 15 A fuse rating