[. . . ] LCD Projector CP-X385W USER'S MANUAL Thank you for purchasing this projector. Vol. 1 (Basic) WARNING · Please read the accompanying manual "SAFETY INSTRUCTIONS" and this "USER'S MANUAL" thoroughly to ensure correct usage through understanding. After reading, store this instruction manual in a safe place for future reference. NOTE · The information in this manual is subject to change without notice. · The manufacturer assumes no responsibility for any errors that may appear in this manual · The reproduction, transmission or use of this document or contents is not permitted without express written authority. [. . . ] (Even if you don't do anything, the dialog will automatically disappear after a few seconds. ) Press the MUTE button again to restore the sound. VOLUME KEYSTONE ENTER POSITION ASPECT FREEZE MAGNIFY ON OFF RESET ESC MUTE MUTE VOLUME SEARCH 16 17 ADJUSTING THE POSITION 1 Press the POSITION button As illustrated on the right, a dialog will appear on the screen to aid you in adjusting the position. STANDBY/ON LASER BLANK VIDEO RGB POSITION POSITION AUTO MENU KEYSTONE ENTER 2 RESET ESC MUTE VOLUME Use the , the position , , buttons to adjust POSITION ASPECT FREEZE MAGNIFY ON OFF When you want to initialize the position, press the RESET button during adjustment. Press the POSITION button again to close the dialog and complete this operation. (Even if you don't do anything, the dialog will automatically disappear after a few seconds. ) This function is only available for RGB IN 1/2 input. SEARCH Control panel 18 USING THE AUTOMATIC ADJUSTMENT FEATURE 1 STANDBY/ON LASER BLANK VIDEO RGB Press the AUTO button AUTO Automatic Adjustment for RGB Input Horizontal position (H. Make sure that the application window is set to its maximum size prior to attempting to use this feature. Use a bright screen when adjusting. AUTO MENU KEYSTONE ENTER POSITION ASPECT FREEZE MAGNIFY ON OFF RESET Automatic Adjustment for Video Input The signal type best suited for the respective input signal is selected automatically. This feature is available only if VIDEO is set to AUTO in the INPUT menu. ESC MUTE VOLUME SEARCH NOTE The automatic adjustment operation requires approximately 10 seconds. Also, please note that it may not function correctly with some input signals. 19 CORRECTING KEYSTONE DISTORTIONS STANDBY/ON LASER BLANK 1 Press the KEYSTONE button As illustrated on the right, a dialog will appear on the screen to aid you in correcting the distortion. KEYSTONE KEYSTONE KEYSTONE VIDEO RGB 16 AUTO MENU 2 KEYSTONE ENTER Use the , buttons to select the direction of distortion to correct ( / ) POSITION ASPECT FREEZE MAGNIFY ON OFF RESET ESC MUTE VOLUME 3 Use the distortion , buttons to correct the SEARCH Press the KEYSTONE button again to close the dialog and complete this operation. (Even if you don't do anything, the dialog will automatically disappear after a few seconds. ) Control panel NOTE · This function may not be work well with some types of input signals. · The adjustable range for correcting keystone distortions will vary with the type of input signal. 20 USING THE MAGNIFY FEATURE STANDBY/ON LASER BLANK 1 Press the MAGNIFY (ON) button The projector enters MAGNIFY mode. MAGNIFY ON VIDEO RGB Press the POSITION button, then , , 2 , buttons to select the area touse the and then enlarge press the POSITION button again to confirm your selection POSITION POSITION AUTO MENU KEYSTONE ENTER POSITION ASPECT FREEZE MAGNIFY ON OFF RESET 3 Press the , buttons to zoom in and out of the selected area. Press the MAGNIFY (OFF) button to exit MAGNIFY mode and restore the screen to normal. (The projector will also automatically exit MAGNIFY mode if there is a change in the input signal's state. ) ESC MUTE VOLUME SEARCH NOTE The projector will automatically exit from MAGNIFY mode if either the INPUT SELECT, AUTO, ASPECT or VIDEO feature is used, or, if there is a change in the input signal's state. FREEZING THE SCREEN ENTER POSITION ASPECT FREEZE MAGNIFY ON OFF RESET 1 Press the FREEZE button The [II] icon appears and the screen will freeze at the current image. Press the FREEZE button again and the [ ] appears as the projector exits FREEZE mode. FREEZE ESC MUTE VOLUME SEARCH NOTE · The projector will automatically exit from FREEZE mode if either the POSITION, VOLUME, MUTE, AUTO, BLANK ON/OFF or MENU ON/OFF feature is used, or, if there is a change in the input signal's state. · If the projector continues projecting the same image for a long time (i. e. you forget to exit FREEZE mode), the image might possibly remain as an afterimage. Do not leave the projector in FREEZE mode for too long. 21 SIGNAL SEARCHING POSITION ASPECT FREEZE MAGNIFY ON OFF RESET 1 Press the SEARCH button When you press the SEARCH button, the projector begins searching for input signals. If it detects an input signal, the search will cease and the projector will project the detected signal. If the projector is unable to find an input signal at any of its ports, it will return to the state it was in prior to the search. SEARCH ESC MUTE VOLUME SEARCH RGB IN 1 RGB IN 2 VIDEO IN S-VIDEO IN COMPONENT VIDEO SELECTING THE ASPECT RATIO AUTO MENU 1 KEYSTONE ENTER Press the ASPECT button ASPECT POSITION ASPECT FREEZE MAGNIFY ON OFF RESET ESC MUTE VOLUME RGB IN 1, RGB IN 2, COMPONENT VIDEO (HDTV signals : 1125i (1035i/1080i), 750p) 4:3 16:9 VIDEO IN, S-VIDEO IN, COMPONENT VIDEO (Non-HDTV signals : 525i, 525p, 625i) 4:3 16:9 SMALL SEARCH TEMPORARILY BLANKING THE SCREEN STANDBY/ON LASER BLANK 1 Press the BLANK button The input signal screen is shut off, and a blank screen appears. You can set the blank screen using the menu (from the SCREEN menu, select BLANK). Press the BLANK button again to remove the blank screen, and return to the input signal screen. BLANK VIDEO RGB AUTO 22 USING THE MENU FUNCTIONS STANDBY/ON LASER BLANK 1 Press the MENU button MENU VIDEO RGB The menu display appears on the screen. The projector has the following menus: MAIN, PICTURE-1, PICTURE-2, INPUT, SCREEN, and OPTION. The current settings of the items that can be manipulated via the selected menu appear. 2 AUTO MENU KEYSTONE ENTER POSITION ASPECT FREEZE MAGNIFY ON OFF RESET / Select a menu using the buttons, then press the or ENTER button. The display of the selected menu appears. Adjusting SHARPNESS] Use the / buttons to select PICTURE-1, then press the or ENTER button. MENU MAIN PICTURE-1 PICTURE-2 INPUT SCREEN OPTION COLOR BAL R COLOR BAL B SHARPNESS COLOR TINT ­1 +1 ­1 +1 ­1 ESC MUTE VOLUME ENTER : SELECT 3 Select an item using the or ENTER button. / buttons, then press the The operation display of the selected item appears. [. . . ] Also steadily push the opposite side of the screwed lamp into the unit. 2 3 4 7 Replace the lamp cover in position and tighten the two screws firmly. 5 Loosen the three screws, and gently remove the lamp while holding the grips. Touching the inside of the lamp case may result in uneven coloring. 8 Gently turn the projector rightside up. ATTENTION · Make sure that the screws are screwed in firmly. Loose screws could result in damage or injury. · Do not use with lamp cover removed. The message functions will not operate properly if the lamp timer is not reset correctly. [. . . ]