[. . . ] Operating and Installation Instructions
Ventilation System DA 5321 D
To prevent accidents and appliance damage, read these instructions before installation or use.
en - US, CA
M. -Nr. 31
2
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS Keep these instructions in a safe place and pass them on to any future user. Read these instructions carefully before installing or using the Ventilation System. Use the appliance only for its intended purpose.
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
~ a) Use this appliance only in the
manner intended by the manufacturer. [. . . ] The indicator for the grease filter will light after 30 hours of operation or the preselected time. After the grease filter has been cleaned and put back in place, the grease filter timer must be re-set. Checking the grease filter timer To check the percentage of time already used:
^ Press the On/Off button to turn the fan on.
^ To do this, press the grease filter button for about 3 seconds while the fan is running. The indicator lights.
The number of flashing "/+" indicators show the percentage of programmed hours that have been used. 1 indicator 2 indicators 3 indicators 4 indicators = 25 % = 50 % = 75 % = 100 %
This information will remain stored in memory in the event of a power failure.
14
Operation
Reprogramming the grease filter timer The grease filter timer is preset to 30 hours. A time of 20 hours should be programmed in kitchens with frequent pan or deep frying. A time of 20 hours should also be programmed if the kitchen is only used occasionally to prevent grease which has accumulated over a long period of time from hardening on the filter, making cleaning more difficult.
The lit "/+" indicator shows the programmed time: 1st indicator from the left 2nd indicator from the left 3rd indicator from the left 4th indicator from the left = = = = 20 hours 30 hours 40 hours 50 hours
^ Use the "/+" button to select the desired time.
^ Store the selection by pressing the grease filter button. If the procedure is not stored within 4 minutes of programming the hood will automatically default to the "old" data.
^ Press the Delayed Shut Down and grease filter button at the same time. The indicator for the grease filter timer and one of the "/+" indicators will flash.
15
Cleaning and care
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". Avoid: cleaning agents containing soda, acids or chlorides, abrasive cleaning agents e. g. pot scourers or sponges which have been previously used with abrasive cleaning agents. These will damage the surface.
Cleaning the casing
Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. ^ The exterior surfaces and controls can be cleaned with a mild solution of warm water and liquid dish soap applied with a soft sponge. ^ Glass surfaces can be cleaned using glass cleaner.
The following instructions for cleaning "Stainless steel" surfaces and "Stainless steel colored controls" should be followed in addition to the general "Cleaning the casing" instructions. Stainless steel Stainless steel surfaces can be cleaned using a non-abrasive stainless steel cleaner. To help prevent resoiling, a conditioner for stainless steel can also be used. Stainless steel colored controls These controls may become discolored or damaged if not cleaned regularly. Do not use a stainless steel cleaner on these controls.
16
Cleaning and care
Grease filter
The reusable metal grease filter removes solid particles from the vented kitchen air (grease, dust, etc). Removing the grease filter
The grease filter should be cleaned every 3 - 4 weeks, when the grease filter indicator lights, or when they are visibly dirty, whichever comes first.
, A dirty filter is a fire hazard.
^ To remove the grease filter pull the locking clip forward. Support the grease filter so that it does not fall onto the cooktop.
17
Cleaning and care
Cleaning the grease filter ^ By hand: use a scrub brush with a solution of warm water and mild detergent. [. . . ] See "Important Safety Instructions" for further information.
25
Structural support
The ceiling mounting plate will support the weight of the hood. This ceiling plate must be attached to rigid structural framing that is supported in its entirety by the ceiling joists, or to the ceiling joists directly. Do not attach the plate directly to the ceiling with anchors, toggle bolts, etc.
, CAUTION
When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.
26
Installation
Protective film
The casing is covered with a protective film to prevent scratching during transport. (S8 wall anchors included in the packaging are not for use in USA)
Installation accessories
To avoid risk of hand or other injury, avoid contact with sharp edges during the assembly and installation process.
, CAUTION
2 Screws M 4 x 8 mm for adjusting the chimney.
4 leveling plates for correcting an uneven ceiling.
1 exhaust connector
1 hose clip for securing the ducting.
27
Air extraction , WARNING
Danger of toxic fumes. [. . . ]