[. . . ] If you need more technical information, do not hesitate to e-mail us at tech@hannainst. com. TABLE OF CONTENTS Preliminary Examination . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Functional Description & Specifications of HI 9056 . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Functional Description & Specifications of HI 9057 . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] See pages 14-17 for more details. FUNCTIONAL DESCRIPTION AND SPECIFICATIONS FOR HI 9056 1. Memory Recalling Key. Specifications Range Resolution Accuracy (@20°C / 68°F) Typical EMC Deviation Probe Battery Environment Dimensions Weight -200. 0 to 1370°C 0. 1°C (-200. 0 to 999. 9°C) 1°C (1000 to 1370°C) ±0. 2% F. S. for one year, excluding probe error ±3°C ±6°F K-thermocouple (optional) (see pages 14-17) 9V/300 hours of continuous use 0 to 50°C (32 to 122°F); 95% RH 180 x 83 x 40 mm (7. 1 x 3. 3 x 1. 6") 350 g (12. 4 oz. ) 4 5 FUNCTIONAL DESCRIPTION AND SPECIFICATIONS OF HI 9057 OPERATIONAL GUIDE INITIAL PREPARATION Remove the battery cover on the rear of your thermometer, unwrap the battery and connect it to the clip. Insert the battery into the compartment and replace the cover. To switch on, press ON/OFF on the front of the unit. ON OFF 1. Measuring Scale key (°C or °F). Specifications -200. 0 to 1370°C / -300. 0 to 2500°F -200. 0 to 900. 0°C / -300. 0 to 1650°F -200. 0 to 400. 0°C / -300. 0 to 750. 0°F Resolution 0. 1°C (up to 999. 9°C) 0. 1°F(up to 999. 9°F) 1°C (over 1000°C) 1°F (over 1000°F) Accuracy K= ±0. 2% F. S. for one year, excluding probe error Typical EMC ±3°C Deviation ±6°F Probe K, J and T thermocouple (optional) (for K-thermocouple see pages 14-17) Battery 9V/300 hours of continuous use Environment 0 to 50°C (32 to 122°F); 95% RH Dimensions 180 x 83 x 40 mm (7. 1 x 3. 3 x 1. 6") Weight 350 g (12. 4 oz. ) Range K J T The thermometer performs a self diagnostic test. The LCD dispalys all the segments at once, to ensure none are missing. BAT HOLD KJT ºC ºF HI LO After the test, the thermometer will switch to the measurement mode. If a temperature probe is plugged in, the unit will display the temperature. If the probe is not plugged in, the display will show "----". To switch your thermometer off, press ON/ OFF again. MEASURING SCALE (°C/°F) (HI 9057 only) When the meter is turned on, it automatically defaults to the °C scale. Measurements can be performed on either the Centigrade or the Fahrenheit scale. 6 7 To change the scale, press °C/°F once. °C °F °F Check the highest or lowest measured temperature by pressing the respective HI or LO key. The appropriate display indicator, "HI" or "LO", will light up together with the value retrieved from memory. °C HI MEASUREMENT RESOLUTION When switched on, HI 9056 °C and HI 9057 default to a 0. 1 digit resolution (see specifications). These instruments automatically change the resolution to 1 degree when the measured temperature is higher than 999. 9°C. In HI 9056, when the temperature is lower than 999. 9°C it is possible to change the resolution by pressing the 0. 1/1 key. HOLD MODE (HI 9057 only) The reading hold function is activated by the HOLD key. To freeze the measured temperature on the display, press and hold the HOLD key. "HOLD" is displayed when this key is pressed. °C LO Release the key to resume normal operation. CLEAR HI-LO FUNCTION (HI 9057 only) By pressing HI and LO simultaneously the present measurement reading is assigned in memory as the highest and lowest temperature reading, i. e. both "HI" and "LO" will have equal temperature readings. HOLD As soon as the HOLD key is released, the meter returns to normal operational mode. HI-LO FUNCTION (HI 9057 only) Maximum and minimum temperatures are monitored throughout a continuous measuring process. The values may be recalled or cleared at any time during the measurement. 8 MEMORY FUNCTION (HI 9056 only) The memory & hold function is activated by MEM HOLD. The measured temperature is stored in memory and frozen on the display when this function key is pressed and held. MEM HOLD 9 The memory value will be overridden each time the memory & hold function is activated. [. . . ] 1. 4" HI 766E1 General use probe, max 900°C/1650°F 260mm 10. 2" 120mm 4. 7" 3mm 0. 12" Other accessories: HI 710002 Soft carrying case HI 710009 Blue rubber boot HI 710010 Orange rubber boot 17 16 WARRANTY All Hanna Instruments meters are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The electrodes and the probes are guaranteed for a period of six months. Damage due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. [. . . ]