[. . . ] - Wait at least 3 minutes before restarting, after the air-conditioner has been switched off or the thermostat setting changed. - Before moving the air-conditioner, remove tank and empty water from collectiong tray (see instructions for drainage at page 12). - Important: If you need to use an extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge).
SAVE THESE INSTRUCTIONS
2
Dear user, We thank you for purchasing the Pinguino air-conditioner and congratulate you on your wise choice. For optimal results please read this manual carefully before installing or operating. [. . . ] Make sure there are no sources of heat in the room.
SPECIAL NOTE
This machine is designed to be used with or without water. When used without water, Pinguino will operate at about 67% cooling capacity.
HOW TO PREPARE WATER CONTAINER
Use only clean, salt-free tap water. The water is essential for the air cooling operation and si discharged in the form of steam through the exhaust outlet. A container full of water lasts for a period that depends on a number of conditions such as temperature, humidity, insulation, exposure of the room, number of people present, etc. When the container is empty, the appliance automatically changes function from water to air. At the same time, the quantity of air discharged from the rear hose will increase.
fig. 14 Open the water container compartment door, tip the container forwards and lift up to remove Remove the cap, pull out the extendable tube and fill the container, standing it on the floor. After filling, replace the extendable tube, screw the cap on tightly and return the container to its place, making sure the word FRONT is facing out.
During "water condensation" cooling function and in particularly quiet surroundings (eg. seawater or water treated using softening systems that utilize kitchen salt.
9
DESCRIPTION OF PINGUINO PAC 250U CONTROLS
ON/OFF button
ON/OFF pilot light
A B C
"Alarm" pilot light Timer ON/OFF pilot light
Timer notches
Thermostat
Timer ON/OFF button
Selecting fan speed button
SETTING THE TIMER The programmer/timer, like all clocks, must be set to the exact time. If for example it is 4. 00 p. m. , turn the dial in a clockwise direction (following the direction of the arrow) until the number 4 is lined up with the arrow pointer (the arrows indicates 4:00 p. m. 2) Set the operating times by pushing out the notches on the dial corresponding to the period required (each notch represents 15 mins. ). 3) Check that the timer indicates the correct time (see instructions on setting).
Funzionamento Operating time
11
10
9
eg. from 9 to 11 a. m.
11
10
9
arrow pointer
Note:Never turn the dial in an anti-clockwise direction!The timer is in effect, an electric clock and works only if the plug is connected to the power supply. Whenever the plug is disconnected or there is a power failure, the programmer stops (the clock is then "slow") and must be re-set. N. B:
For technical reasons, the temperature is not expressed in degrees but by a line increasing in thickness. We therefore recommend that when starting up the appliance, the thermostat be turned to maximum (thick green line = maximum cold). When the desired temperature has been reached, turn the thermostat slowly away from the maximum cooling position until the appliance switches off. The air-conditioner is now programmed to maintain the exact temperature at all times.
After switching the appliance off, wait at least 3 min. before switching on again.
10
4
4
4) Select the desired function as shown in the chart overleaf. Note: To override the programmed operating times, simply press the ON/OFF key. NON-PROGRAMMED MODE 1) B TIMER button must be pressed 2) Select the desired function as shown in the chart on the following page.
HOW TO START UP THE CONDITIONER (see control panel on the previous page)
Plug the appliance into the mains.
Select the "programmed" or "non programmed" mode (see previous page)
Select the fan speed required pressing "Fan speed" key C.
AIR-CONDITIONING
Key A ON/OFF (conditioning) must be released Turn the thermostat to Max. [. . . ] 625 WASHINGTON AVENUE CARLSTADT, NJ 07072
FOR CANADA ONLY:
LIMITED WARRANTY
We warrant each DE'LONGHI AIR-CONDITIONER to be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This warranty shall apply only if the AIR-CONDITIONER is used in accordance with the factory directions which accompany it, and on Alternating Current (AC) circuit. This warranty is in lieu of all other warranties and representations, expressed or implied, and all other obligations or liabilities on our part. [. . . ]