[. . . ] Indoor Units Wall Mounted (K2 type) S-15MK2E5A S-22MK2E5A S-28MK2E5A S-36MK2E5A Indoor Units 4-Way Cassette 60x60 (Y2 type) S-15MY2E5A S-22MY2E5A S-28MY2E5A S-36MY2E5A S-45MY2E5A S-56MY2E5A
Operating Instructions Air Conditioner
Outdoor Units mini (LE1 type) U-4LE1E5 U-5LE1E5 U-6LE1E5 U-4LE1E8 U-5LE1E8 U-6LE1E8 2WAY (ME1 type) U-8ME1E81 U-10ME1E81 U-12ME1E81 U-14ME1E81 U-16ME1E81 U-18ME1E81 U-20ME1E81 3WAY (MF2 type) U-8MF2E8 U-10MF2E8 U-12MF2E8 U-14MF2E8 U-16MF2E8
2 ~ 15 ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 172
PRODUCT INFORMATION
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet. _______________________
Date of purchase ______________________________________________________________ Dealer’s address ______________________________________________________________ Phone number________________________________________________________________
SAFETY PRECAUTIONS
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. [. . . ] The airflow direction may be different from the display on the remote controller. Zone ‘‘A’’ for cooling Zone ‘‘B’’ for heating
Indoor unit
Horizontal directions (manual) The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the left or right. Fm Page 11 Wednesday, December 11, 2013 9:41 AM
ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE REMOTE CONTROLLER (WIRED)
• Auto Flap ( ) button • If multiple indoor units are connected to a remote controller, the airflow direction can be set for each indoor unit by selecting the indoor units (see the operation below). Set the airflow direction for the indoor unit that is shown on the display. Each time UNIT is pressed, the indicator changes in the order shown below. When nothing is displayed, you can make the setting for all indoor units in one operation. The unit number is displayed as Outdoor Unit Number–Indoor Unit Number. 2–4
• • •
One outdoor unit and eight indoor units
No display Unit No. Fm Page 12 Wednesday, December 11, 2013 9:41 AM
SPECIAL REMARKS
‘‘DRY’’ Operation
How it works • • • • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating. ‘DRY’’ operation is not possible if the outdoor temperature is 15 °C or less. Heating Operation
Heating performance • Because this appliance heats a room by utilizing the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this heat pump, use another heating appliance in conjunction with this unit. When the outdoor temperature is low, frost or ice may form on the outdoor heat exchanger coil, reducing the heating performance. when this happens , a microcomputer-controlled defrosting system operates. At the same time, the fan on the indoor unit stops (or runs at very low speed in some cases) and the ‘‘STANDBY’’ indicator appears on the display until defrosting is completed. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms. ) For several minutes after the start of heating operation, the indoor fan will not start running (or it will run at very low speed in some cases) until the indoor heat exchanger coil has warmed up sufficiently. During this period, the ‘‘ ’’ (standby) indicator remains displayed. ‘ ’’ (standby) remains displayed during defrosting or when the compressor has been turned off (or when the unit is running at very low speed) by the thermostat when the system is in the heating mode. Upon completion of defrosting and when the compressor is turned on again, ‘‘ ’’ (standby) will turn off automatically as heating operation resumes. Defrosting
•
(standby) on the display
•
•
• NOTE
Should the power fail while the unit is running If the power supply for this unit is temporarily cut off, the unit will automatically resume operation (once the power is restored) using the same settings before the power was cut off. [. . . ] The content of hazardous substance with the exemption of the applications listed in the Annex №2 of TR on RoHS: 1. Lead (Pb) – not over 0, 1wt % or 1000wt ppm; Cadmium (Cd) – not over 0, 01wt % or 100wt ppm; Mercury (Hg) – not over 0, 1wt % or 1000wt ppm; Hexavalent chromium (Cr6+) – not over 0, 1wt % or 1000wt ppm; Polybrominated biphenyls (PBBs) – not over 0, 1wt % or 1000wt ppm; Polybrominated diphenyl ethers (PBDEs) – not over 0, 1wt % or 1000wt ppm. Untuk mencegah kemungkinan bahaya akibat kegagalan isolasi, unit harus diarde Jangan bersihkan sendiri bagian dalam unit indoor dan outdoor. Jangan masukkan jari tangan Anda atau benda lain ke unit dalam atau unit luar pendingin ruangan, suku cadang yang berputar bisa mengakibatkan cedera. [. . . ]