[. . . ] BOOK# 091-9-1000 pump plus-reva
4-16-2002
INSTRUCTION MANUAL
AUTO CHARGE 1000
PUMP-PLUS
AIR COMPRESSOR / BATTERY CHARGER
MODEL #091-9-1000
NOTE : This charger is designed for vehicles with single battery system and negative ground. INPUT :120 volt, 50/60 Hz, 3. 5 amps OUTPUT: 18 AMPERES 1 YEAR WARRANTY ON AIR COMPRESSOR 3 YEAR WARRANTY ON CHARGER
KUSSMAUL ELECTRONICS CO. , INC.
170 CHERRY AVE. , WEST SAYVILLE, N. Y. 11796
TEL: in NY 631-567-0314 TOLL FREE: 800-346-0857 FAX: 631-567-5826
Introduction The AUTO CHARGE 1000 Pump Plus is a compact, completely automatic, single channel battery charger designed for vehicles with a single battery system. [. . . ] This battery voltage is compared to a standard and any error is detected and used to control the charger output at the desired level. Their is no "trickle charge" and therefore no danger of overcharging and water boil-off. Automatic Current Limiting When batteries are severely discharged, some battery chargers can be overloaded due to the high charging current required. This circuit limits the output current to the rated 15 amperes when charging a deeply discharged battery or if the starter cranks the engine while charging. The current limiter thus eliminates the need for an ignition interlock circuit.
Battery Saver & Indicator A 3 ampere BATTERY SAVER is built into the charger. When connected as shown in the installation wiring diagram, loads on the battery such as radios and rechargeable hand lights are automatically switched to the BATTERY SAVER when power is applied to the charger. The BATTERY SAVER allows more efficient charging by removing these loads. A BATTERY SAVER overload indicator alerts the operator that the BATTERY SAVER load has exceeded 3 amperes. Reapply the load to the BATTERY SAVER
No fuses are required or provided as the BATTERY SAVER contains an electronic overload interrupter.
Remote Battery Charge Condition Indicator This remote indicator shows the charge condition of the battery in 10 levels from "LOW CHARGE" to "FULLY CHARGED". This device indicates a defective battery when a bar graph does not rise to the "FULLY CHARGED" level after an extended period of charging. NOTE: If a battery is being charged with an external load of 1. 5 to 4 amperes across it's terminals, the bar graph may move down 1 or 2 levels. To avoid this, connect all external loads to the BATTERY SAVER terminals. Loads connected to the BATTERY SAVER will be powered either from the BATTERY SAVER power supply when the A. C. power is "ON", or they will be connected to the battery when the A. C. power is "OFF".
Installation Wiring Diagram
NOTE: INDICATOR WIRING, PIN 1 OF INDICATOR MUST GO TO PIN 1 OF CHARGER, PIN 2 OF INDICATOR TO PIN 2 OF CHARGER AND SO FORTH. PLEASE CHECK CONNECTORS AND COLOR OF WIRES BEFORE PLUGGING IN.
Auto Charge 1000 Pump Plus
PUMP PLUS
1 2
Auto Pump Air Compressor
3 4
1000
BATTERY SAVER OVER LOAD POWER
AUTO PUMP
+
COM CHARGER POSITIVE BAT 1 B. S.
Note: make sure the Auto Pump is mounted vertical.
AUTO PUMP DC AC
Pressure Switch
Chassis Ground Chassis Ground
+ 12 Volts
BLK BLK RED RED
Chassis Ground
Range Nut
Accessories
Battery Saver Loads (3 amps max. ). [. . . ] shall have no liability for damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others.
INDICATOR INSTALLATION 1. Insert 4 #6-32 screws and tighten, (CAUTION Do not over tighten because you will bend the plastic bezel and brake the watertight seal).
HOLE TEMPLATE [. . . ]