[. . . ] 1 Locate the SCSI jumper cables connecting each pair of tape drives in the library and the host systems (see figure 3 for PX502, figure 4 for PX506, and figure 5 for PX510). The tape drives are numbered 1 through 10 (depending on library model) starting in the top-left drive bay. Tape drive 1 is in the upper right-hand drive bay, tape drive 2 is in the upper lefthand drive bay, and so forth. [. . . ] The FC1202 Home Page screen displays (see figure 17).
Figure 17 FC1202 Home Screen
Main menu
FC1202 Upgrade Procedure
21
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 A01 June 2005
Configuring the FC1202 Bridge
0
To configure the FC1202 bridge and map the tape drives to the Fibre Channel ports: 1 From the Home screen, click Ports from the main menu. The Ports screen displays (see figure 18).
Figure 18 FC1202Ports Screen
2 Click FC Port. The FC Port Configuration screen displays (see figure 19).
22
FC1202 Upgrade Procedure
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 A01 June 2005
Figure 19 FC Port Configuration Screen
Port mode
Performance mode
3 Ensure that the settings for Port mode and Performance mode are as follows: · · · · · · Port mode - Auto Sense Use Hard AL_PA - disabled Discovery Mode - Manual Discovery Only Buffered Tape Writes - Enabled Buffered Tape Queue Depth - 3 Performance mode - 2 Gigabits If the Fibre Channel network is only capable of 1 Gigabit speeds, set the Performance mode to 1 Gigabits.
Note:
4 Click Discovery from the Main menu. The Discovery screen displays (see figure 20).
FC1202 Upgrade Procedure
23
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 A01 June 2005
Figure 20 Discovery Screen
Discovery Go
5 Click Go to discover all attached devices. The Mapping screen displays (see figure 21).
Figure 21 Mapping Screen
7 Click FC Port from the Mapping menu. The Edit/View Map screen displays (see figure 22).
24
FC1202 Upgrade Procedure
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 A01 June 2005
Figure 22 Edit/View Map Screen
Fill map
10 Figure 23 displays the current mapping for the Fibre port. The display should show the first pair of tape drives from SCSI bus 0 and 1 along with a robot (changer) if this is the first bridge in the card cage.
Figure 23 Mapped SCSI Devices
Mapped SCSI devices
11 Click Fill Map to all attached SCSI drives and verify their presence
in the map.
12 Use Delete Items Map Control to remove devices that do not belong on
this Fibre Channel port to match the list in step 10.
FC1202 Upgrade Procedure
25
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 A01 June 2005
13 Close the Edit/View window. 15 After activating the mapping options for the FC port, click Reboot from the Main menu. The System Reboot screen displays (see figure 24).
Figure 24 System Reboot Screen
16 Select Yes and click Submit. The FC1202 reboots.
Saving the Configuration File
0
After the FC1202 initial installation and configuration or after any changes are made to the FC1202, you must save the configuration file to a local host. The configuration file contains all configurable parameters such as IP address and mapping information. This configuration file can be uploaded to a replacement FC1202 bridge and eliminate the configuration portion of this instruction. To save a configuration file using the FTP utility: 1 Click FTP Utility from the Utilities menu. The FTP Utility screen displays (see figure 25).
26
FC1202 Upgrade Procedure
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 A01 June 2005
Figure 25 FTP Utilities Screen
The FTP utility requires the use of a JAVA applet and prompts for permission to install the applet, if needed. If the prompt is displayed, follow the onscreen instructions to complete the installation. Note: Internet access is required to verify the signature for the FTP applet and to download the JAVA applet plug-in for your browser.
2 Enter the User Name, Password, and the IP address of the Interface Controller and click Connect. Note: The configuration file should be named <myconfigfile. cfg> when typing it into the FTP window.
The following file types can be downloaded from the Interface Controller: · · · Configuration (. cfg) Traces for the current boot cycle (curtrace. txt) Traces from the previous boot cycle (prvtrace. txt)
4 Click Binary Transfer mode. The configuration file is saved to the local host.
FC1202 Upgrade Procedure
27
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 A01 June 2005
Enabling Serverless Backup (Xcopy) 0
Serverless backup (also known as SNIA Extended Copy and XCOPY) addresses the needs of users for full time data availability and small backup windows by relegating all backup related tasks to the SAN. [. . . ] The VLAN Menu displays (see figure 31).
Figure 31 VLAN Menu
3 Type 1 and press <Enter>. The Configure VLANs Menu displays (see figure 32).
Zoning the Ethernet Switch
31
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 A01 June 2005
Figure 32 Configure VLANs Menu
4 Type 1 and press <Enter>. The Create VLAN Menu displays (see figure 33).
Figure 33 Create VLAN Menu
Table 4 Recommended Zoning Example
Library Type PX506
Number of FC Bridges 3
Switch Zones First zone - ports 1 through 4 for connections from library SCB and three FC1202 bridges. [. . . ]