User manual AEG-ELECTROLUX DD8760M/S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX DD8760M/S. We hope that this AEG-ELECTROLUX DD8760M/S user guide will be useful to you.


AEG-ELECTROLUX DD8760M/S : Download the complete user guide (1825 Ko)

You may also download the following manuals related to this product:

   AEG-ELECTROLUX DD8760M/S (531 ko)
   AEG-ELECTROLUX DD8760M/S (509 ko)
   AEG-ELECTROLUX DD8760M/S (525 ko)
   AEG-ELECTROLUX DD8760M/S (494 ko)
   AEG-ELECTROLUX DD8760M/S (495 ko)

Manual abstract: user guide AEG-ELECTROLUX DD8760M/S

Detailed instructions for use are in the User's Guide.

[. . . ] National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room. Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood. If you have any doubts, contact the relevant controlling authority or building inspectors office. Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood. [. . . ] The hood operation can be controlled via the control ball or with the remote control (the remote control is a special accessory and is ordered separately). Every change (changing speed, switching on the lights, etc. ) is recognizable from the variation of light emitted by the control ball and by an acoustic signal. The control ball is located below on the right side of the cooker hood. The control ball is also a light signal : No signal : The hood is switched off. Flashing red light : Hood is switched on at intensive power level (timed at 5 minutes) Flashing green light : Indicates the grease filter saturation - clean the grease filter Flashing orange light : Indicates the charcoal filter saturation - clean or replace the charcoal filter. The control ball flashes orange to indicate the saturation of the charcoal filter even if the hood is used in the extractor version and no charcoal filter is fitted. In this case, perform the signal reset operation as follows: select the intensive speed (the control ball lights up with a red flashing light), depress again and hold depressed for about 3 seconds until an audible signal indicates the reset has taken place. Depressing the control ball repeatedly towards the bottom, switches on the hood and you may select the motor level desired, depressing once again the hood switches off. depress towards the bottom to switch on the hood. Switching on the light - Fig. 3 Depress the control ball towards the top : once for submersed lighting, once again for full lighting, depress again to switch off the light. Indicator light for grease or charcoal filter The air duct, in this hood, includes a device that signals when the filter requires cleaning or changing . depress towards the top to switch on the lights Fig. 3 Led signal for grease filter The LED signal flickers (flickering green light) when the grease filter requires cleaning, occurs at about 40 operating hours. Ensure that the indicator light is checked each time the hood is used. Led signal for charcoal filter The LED signal flickers (flickering orange light) when the charcoal filter requires cleaning, occurs at about 160 operating hours. The charcoal filter can be ordered from your local AEG Service Force Centre. 6 grease filter 64 Warning Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations. Changing the light bulb Disconnect the cooker hood from the mains supply. If the light does not come on, make sure the bulb has been inserted correctly before contacting your local Service Force Centre. Connector Fig. 7 Changing the upper light DD 8765 Disconnect the cooker hood from the mains supply. Remove the light cover by unscrewing the two side screws (hold the light cover when Light carrying out this operation so that it does not fall). If the light does not come on, make sure the bulb has been inserted correctly before contacting your local Service Fig. Starter 65 Changing the side light DD 8765 Disconnect the cooker hood from the mains supply. Remove the front and side panels (for the latter proceed in reverse order to the montage see operations 10-11 of the wall mounting paragraph on the following pages). If the light does not come on, make sure the bulb has been inserted correctly before contacting your local Service Force Centre. Remote control RM 8700* Telescopic chimney (for extractor version only)* Stainless steel side panels (Only DD 8794)* Aluminium side panels * Not available in UK. [. . . ] Drill two holes Ø 8mm and fix the support bracket with two wall plugs and screws (3). Hang the hood (4) adjust its position (5-6) and from the inside of the hood sign two points for definitive fixing (7), remove the hood and drill two holes Ø 8mm (8), fit two wall plugs, hang the hood again and fix it securely with two screws (9). Cover the drill holes for screws with the two screw caps provided. 4 (5x18) 6 5 5 3 7 8 (5x18) 6 4 8 2 1 9 Fig. 11 71 Fix the sides of the cooker hood by 11 fastening the pins (10a) to the sides of the fastening screws (10b). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX DD8760M/S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX DD8760M/S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.