User manual ALESIS QUADRAVERB PLUS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ALESIS QUADRAVERB PLUS. We hope that this ALESIS QUADRAVERB PLUS user guide will be useful to you.


ALESIS QUADRAVERB PLUS : Download the complete user guide (160 Ko)

You may also download the following manuals related to this product:

   ALESIS QUADRAVERB PLUS SUPPLEMENTARY GUIDE (1581 ko)

Manual abstract: user guide ALESIS QUADRAVERB PLUS

Detailed instructions for use are in the User's Guide.

[. . . ] Alesis QUADRAVERB Plus USERS MANUAL ADDENDUM INTRODUCTION The QuadraVerb Plus is an upgraded version of the original QuadraVerb . The many new features that are now available are made possible by a simple software update, which requires only the replacement of its EPROM (Erasable Programmable Read Only Memory). The operation of the QuadraVerb Plus is identical to the original QuadraVerb and all original features of the QuadraVerb are retained in the QuadraVerb Plus . All patches originally written for the QuadraVerb will sound the same on the QuadraVerb Plus. [. . . ] The signal will be distorted if the red "Clip" LED lights. 10 10 PLAYING BACK A SAMPLE There are three ways to play back a recorded sample: from the front panel, from an audio trigger, or through MIDI. Playback from the front panel (manual playback) would normally be used when you want to manually trigger a recorded sample. Playback from an audio trigger is normally used when replacing one audio source with a recorded sample, as in the case of replacing a snare drum on a tape track with a better recorded sample. Playback through MIDI enables a recorded sample to be played from a MIDI keyboard. PLAYBACK FROM THE FRONT PANEL 1) Press the DELAY button. The display will read: SAMPLE PLAYBACK: ONE SHOT One Shot means that once a sample is initiated, it will play until the end of the sample and then stop. To playback again, press the EQ button again. 3) The volume of the sample can be increased or decreased by the OUTPUT control of the QuadraVerb Plus. 1A) If you wish to have the sample play back continuously until told to stop, press the "Down" VALUE button. The display will read: SAMPLE PLAYBACK: LOOPING 2A) To begin playback, press the EQ button. The display will then read: PUSH EQ TO STOP SAMPLE PLAYBACK 3A) To stop playback, press the EQ button again. The next display will read: MIDI TRIGGER LOW LIMIT: 000 2) Press the VALUE "Up" button to select the lowest desired note to trigger the recorded sample. The next display will read: 13 13 MIDI TRIGGER BASE: 060 The Base value is the note where the sample will play back with no pitch change. The next display will read: MIDI TRIGGER HIGH LIMIT: 127 6) Press the VALUE "Down" button to select the highest desired note to trigger the recorded sample. Note number 60 = Middle C. PLEASE NOTE: · Because of the nature of sampling, the timing of the sample as well as the pitch will change substantially the farther away from the base note that it's triggered, with the higher notes sounding like "munchkins" and the lower notes like "giants". The pitch of the sample will follow within a 2 octave range and will loop back into the range if any note information falls outside of the 2 octave range. For instance, if the base note has been selected to note number 60 (Middle C or C3) and note number 84 (C5) is played, the sample pitch will be triggered 1 octave higher than the bass (C4). · ADJUSTING THE SAMPLE PLAYBACK LENGTH In any playback mode it is possible to adjust the sample playback length in order to either ignore unwanted sampled material or "dead air", or in order to make a loop more musical. The display will read: SAMPLE PLAYBACK: ONE SHOT 2) Press the PAGE "Up" button. The display will read: SAMPLE START: 0. 00 SECONDS 14 14 This page will determine at what point in the sample that playback will start. When the start of the sample is moved, the length of a loop is maintained unless the end of the sample is reached before the loop duration. In this case, the loop duration will be from the start to the actual end of the sample regardless of the loop duration. However, the duration value will remain intact and in effect as soon as the user adjustment of the loop start will permit the proper length. The display will read: SAMPLE LENGTH: 1. 55 SECONDS This page will determine the length of the sample playback. [. . . ] Since the ratio between the input signal's harmonics is not preserved, the resulting sound is drastically different from the original. While usual ring modulators only provide a fixed mix of the Up and Down spectrums, the 20 20 100Hz 500Hz 1KHz Freq. algorithm implemented in the QuadraVerb Plus gives independent access to the Up and Down version of the original spectrum. The ring modulator treatment will be most valuable for special effect on voices or sound effects. SELECTING THE RING MODULATOR The Ring Modulator is accessed through new Configuration 6, which is RING MODULATOR->DELAY->REVERB. The block diagram of this configuration is: FIGURE 2 CONFIGURATION 6 RING MODULATOR->DELAY->REVERB BLOCK DIAGRAM RING MODULATOR CONTROL: Spectrum shift amount Ring Mod. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ALESIS QUADRAVERB PLUS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ALESIS QUADRAVERB PLUS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.