User manual AMX AXB-PT101530 POSITRACK CAMERA CONTROLLER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX AXB-PT101530 POSITRACK CAMERA CONTROLLER. We hope that this AMX AXB-PT101530 POSITRACK CAMERA CONTROLLER user guide will be useful to you.


AMX AXB-PT101530 POSITRACK CAMERA CONTROLLER : Download the complete user guide (905 Ko)

Manual abstract: user guide AMX AXB-PT101530 POSITRACK CAMERA CONTROLLER

Detailed instructions for use are in the User's Guide.

[. . . ] instruction manual AXB-PT10/15/30 PosiTrack Camera Controllers C a m e ra C o n t r o l l e r s AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, MX Series products, and KC Series products are warranted for a period of one (1) year. Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. Batteries and incandescent lamps are not covered under the warranty. This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer. [. . . ] Confirm that the necessary programming has been done to the system before beginning the installation process. Pan the unit as far to the left as desired and enter this position into the Axcess program as the left pan-limit stop. Pan the unit as far to the right as desired and enter this position into the Axcess program as the right pan-limit stop. Pan to both programmed stop positions and ensure the pan-limit stops are set correctly. AXB-PT10/15/30 PosiTrack Camera Controllers 25 Installation Tilt Characteristics The tilt drive is factory set to a maximum tilt range of ± 90° (for a total of 180°). Tilt limit stops refer to the vertical range of motion available to the PosiTrack unit and are set via the Axcess program. Setting the adjustable tilt-limit stops The Central Controller should be programmed before beginning. Refer to the Specifications section on page 2 for more information on programming devices. Ensure that there is enough slack in the lens, camera, and PosiTrack controller AXlink cables to accommodate the full range of tilt motion. Tilt the unit as far up as desired and enter this position into the Axcess program as the upper tilt-limit stop. Tilt the unit as far down as desired and enter this position into the Axcess program as the lower tilt-limit stop. Tilt to both stop positions and ensure the tilt-limit stops are set correctly. If you have problems setting the range of motion on either PosiTrack units, you may be setting both limits on the same side of the Home position. See the Configuration Commands table on page 28 for details on the SET HOME command. 26 AXB-PT10/15/30 PosiTrack Camera Controllers Programming Programming The AXB-PT10, AXB-PT15, and AXB-PT30 control capabilities for camera functions include: · Pan · Tilt · Zoom (servomotor; positional) · Zoom (servomotor; speed) · Zoom (motor drive) · Focus (servomotor; positional) · Focus (servomotor; speed) · Focus (motor drive) · Iris (servomotor; positional) · Iris (servomotor; speed) · Iris (motor drive) The PosiTrack Controllers are controlled with device-specific channel settings and Axcess Send_Commands. You create the software programs with the Axcess programming software. Use the programming information in this section, with the Axcess Programming Guide to create a program to control the PosiTrack Camera Controllers. The program resides in the Axcess or NetLinx Central Controller. The commands for ZOOM, FOCUS, and IRIS output to servomotor or motor mode MUST be configured to match the switch settings. Configuration Commands The following table lists in detail the different variables used in the Configuration Commands. These variables consist of parameters which the commands must adhere to. Variables for the Configuration Commands Parameters Outputs Description 1--PAN 2--TILT 3--ZOOM 4--FOCUS 5--IRIS Level 0 (lowest) to 255 (highest) or 0% to 100% On pan, tilt, and PWM drives for zoom, focus, and iris, level 128 will be OFF. Time (optional) Position If specified, 0 to 255 in tenths of a seconds; if not specified, at current rate. Not directly related to an output level voltage. AXB-PT10/15/30 PosiTrack Camera Controllers 27 Programming Variables for the Configuration Commands (Cont. ) Parameters Speed Deviation Distance Ramp Time Description 0 to 127; where 0 is the slowest and 127 is the fastest (default). Default is 2, meaning the position can be within + 2 from the specified position. 1 to 255; time in 10ms increments it takes the motor drives to ramp up to speed. All presets are cleared when any limits are set. Configuration commands configure the manner in which the PosiTrack operates. [. . . ] Once a directory containing one or more . TSK files is specified, a list of available . TSK files is displayed in the upper table in this dialog. Select the target AXlink device from the list of online devices in the lower-left table. Click Download to open the Confirm Communication Settings dialog, where you can review and confirm your Comm Settings and Target Device information before the download begins. Click Cancel to return to the Select Axcess Firmware File dialog, to edit these settings (if necessary). AXB-PT10/15/30 PosiTrack Camera Controllers 49 Upgrading the Firmware Click OK to confirm the Comm Settings and Target Device information, and download the selected . TSK file to the specified device using the selected communications port. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX AXB-PT101530 POSITRACK CAMERA CONTROLLER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX AXB-PT101530 POSITRACK CAMERA CONTROLLER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.