User manual AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM. We hope that this AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM user guide will be useful to you.


AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM : Download the complete user guide (473 Ko)

Manual abstract: user guide AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM

Detailed instructions for use are in the User's Guide.

[. . . ] instruction manual 3 Axcent Integrated Axcess Controllers and 3 Pro Axcent A x c e s s C e n t ra l C o n t r o l l e r s AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the control of dimmable loads that are properly connected to our lighting products. [. . . ] If the IR code for ENTER (IR code 21) is programmed, steps 5 and 6 are performed. · Transmits IR pulses for ENTER (IR code 21) for the time set by CTON. Syntax: "'CP', <channel>" Variables: <channel> = 0 - 252 Example: SEND_COMMAND IR_1, "'CP', 2" Clears pending commands and pulses command number 2. CTOF Sets the single IR pulses off time between channel digits and IR functions. CTOF sets the time between digits or any other pulse and CTON sets the pulse length for each digit. This is the time between digits, or pulses, that is associated with an SP command. Syntax: "'CTOF', <time>" Variables: <time> = 0 - 255 in tenths of a second; Time is stored in permanent memory. Example: SEND_COMMAND IR_1, "'CTOF', 10" Sets the channel's off-time pulse in tenths of a second. Time is stored in non-volatile RAM. 12 Axcent3 and Axcent3 Pro Integrated Axcess Controllers Axcess Programming Send_Commands for the IR/Serial/Data Ports (Cont. ) CTON Sets the IR pulse (single) on time for each channel digit and IR functions. CTON sets the pulse length for each digit and CTOF sets the time between digits or any other pulse. Syntax: "'CTON', <time>" Variables: <time> = 0 - 255 in tenths of a second; Time is stored in permanent memory. Example: SEND_COMMAND IR_1, "'CTON', 20" Sets the pulse length to 2 seconds. GET BAUD Gets the IR/Serial/ Data port's current communication parameters. Syntax: 'GET BAUD' Example: SEND_COMMAND IR_1, 'GET BAUD' System response example: Device 1, 38400, N, 8, 1 GET MODE Gets the IR/Serial/ Data port's current mode setting. Syntax: 'GET MODE' Example: SEND_COMMAND IR_1, 'GET MODE' System response example: Device 8 IR, CARRIER, IO LINK 0 IROFF Stops IR output on the designated device. Syntax: 'IROFF' Example: SEND_COMMAND IR_1, 'IROFF' Stops transmitting IR signals. POD Syntax: 'POD' Disables current PON (power on) or POF (power off) command settings. POF Syntax: 'POF' Sends IR function 28 (if available) or 9 to turn device power off. After three attempts, if the linked I/O channel still detects a power-on status, the controller starts processing stored buffer commands. Then, if another IR function 28 or 9 fails to turn the external device's power off, the controller sends a PUSH and RELEASE of channel 248 and generates a power failure error. If the device is turned on manually, this command turns the external device's power off unless a PON (power on) or POD (disable POF) command is received. PON Syntax: 'PON' Sends IR function 27 (if available) or 9 to turn device power on. [. . . ] With the rear of the unit facing you, insert the new battery with the positive (+) polarity side facing left. Do not use any type of conductive tools to remove the battery. Plug the AXlink and power connectors back into the AXLINK/PWR connectors on the controller. Be sure to write down the next replacement date on a sticker or label by adding five years to the replacement date, and then attach it to the back panel of the controller. Then, insert screws in the left and right side of the controller and tighten. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.