User manual AMX RADIA LIGHTING CONTROL ENCLOSURE WORKSHEET GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX RADIA LIGHTING CONTROL ENCLOSURE WORKSHEET GUIDE. We hope that this AMX RADIA LIGHTING CONTROL ENCLOSURE WORKSHEET GUIDE user guide will be useful to you.


AMX RADIA LIGHTING CONTROL ENCLOSURE WORKSHEET GUIDE : Download the complete user guide (1178 Ko)

Manual abstract: user guide AMX RADIA LIGHTING CONTROL ENCLOSURE WORKSHEET GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Enclosure Worksheet Guide Radia Lighting Lighting Control Document ID: 043-004-2440 Last Revised: 6/15/2006 AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX does guarantee the control of dimmable loads that are properly connected to our lighting products. [. . . ] Enclosures use uniform sized spaces or slots for installation of the dimmers. There are three types of enclosures: surface mounted, in-wall, and those with circuit breakers (FIG. The RDA-ENC8W requires the use of two four-slot Worksheets. In-Wall enclosure FIG. 1 Enclosures Surface enclosures Circuit breakers AMX Lighting - Enclosure Worksheet Guide 1 AMX Lighting - Enclosure Worksheet Guide Worksheet Layout The worksheet is made of columns and rows of information and is divided into a top, middle, and bottom section. 2 shows the layout of a sample Worksheet and their sections. ENCLOSURE CONTROL CARD MODULE AXlink DEVICE # PROlink PACK # DIM # DESCRIPTION / ZONE CURVE TYPE VOLTS LOAD (W) RDA-ENC12B 96 1 120 SLOT 1 1 120 SLOT 2 1 120 TOP SLOT 3 1 120 SLOT 4 SLOT 5 SLOT 6 Card #1 #1 #2 #2 #3 #3 DIP Switch SW1 PROlink SW2 AXlink SW1 PROlink SW2 AXlink SW1 PROlink SW2 AXlink 1 ON * * * * * 2 * * * * * * 3 * * * * * * 4 * * * * * * 5 * * * * * * 6 * ON * * * * 7 * ON * * * * 8 OFF * * * * * DEALER ID DEALER JOB NAME SITE SO# AMX Corp. Richardson, TX 75082 DATE 3/29/2002 MIDDLE PO# SERIAL NUMBERS NOTES BOTTOM ENC 1 2 3 4 5 6 FIG. 2 Worksheet sections In the top section, the columns contain data and information required to configure the hardware and describe the loads. The rows in the top are used for multiple channel descriptions contained in each slot of the enclosure. The bottom section is used for special notes, features descriptions, and serial numbers. Cells There are two main types of `cells' that information is entered into. The next type of information cell is a Text Box that allows the user to type in data to a specified area. The worksheet's drop-down menus let you easily fill in required items in the appropriate place. A gray shaded area indicates where a drop-down menu may be located (FIG. 4), which are used where selections cannot be accommodated with a simple drop-down menu. You can use the TAB key (in the word document) and arrow keys to jump from field to field (cell to cell). 2 AMX Lighting - Enclosure Worksheet Guide AMX Lighting - Enclosure Worksheet Guide Click on arrow next to a drop-down field in a cell to reveal the menu. FIG. 3 Sample drop-down cell Highlight the field with a mouse click and it will darken the color, then use the keyboard to type in text. FIG. 4 Sample text cell What You Must Specify There are three items that you must specify with each worksheet: 1. Dimmer or switch modules The AMX Lighting Enclosure Worksheet is designed so you choose the enclosure first. The next column to the right has the control card, and to the right of that is the menu for the modules. Read This Next Part Carefully Each enclosure has a specified amount of 'slots' or module spaces available for a AMX Lighting dimmer or switch module. A slot is a specific location within the enclosure, whereas a space is a specific amount of area, regardless of location. Most modules require a single space, but several use a double space. An integrated module like the RDD-DM6 can have six dimmers in two module spaces, and the RDM-INC50 has a single dimmer that uses two spaces. Combined with the selection of single, double, and triple dimmers on a single module space makes for a large amount of possibilities for an enclosure. An enclosure may use control cards at different voltages in the same enclosure. If the enclosure uses a DM series of integrated modules (containing a control card), omit this section. [. . . ] This is important because some local electrical codes do not allow mixing of voltages in a single enclosure. Local codes may also require use of a separate container for each voltage device used on the premises. Some dimming modules are phase dependent, and mixed voltages will cause poor dimming performance when the controller is out of phase with the supply voltage to the dimmer. The voltage of the controller chosen often determines what voltages can be specified in the dimmers. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX RADIA LIGHTING CONTROL ENCLOSURE WORKSHEET GUIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX RADIA LIGHTING CONTROL ENCLOSURE WORKSHEET GUIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.