User manual CANDY CBG62

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANDY CBG62. We hope that this CANDY CBG62 user guide will be useful to you.


CANDY CBG62 : Download the complete user guide (1738 Ko)

Manual abstract: user guide CANDY CBG62

Detailed instructions for use are in the User's Guide.

[. . . ] Assembly and electrical connections must be carried out by specialised personnel. Electric Connection The appliance has been manufactured as a class II, therefore no earth cable is necessary. The connection to the mains is carried out as follows: BROWN = L line BLUE = N neutral If not provided, connect a plug for the electrical load indicated on the description label. Where a plug is provided, the cooker hood must be installed in order that the plug is easily accessible. [. . . ] If a connection tube composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the cooker hood exhaust to the same conductor used to circulate hot air or for evacuating fumes from other appliances generated by other than an electrical source. We recommend the use of an air exhaust tube which has the same diameter as the air exhaust outlet hole. If a pipe with a smaller diameter is used, the efficiency of the product may be reduced and its operation may become noisier. Installation The following instruction should be followed to carry out the correct installation of the cooker hood. Fixing the hood to the lower part of the wall cabinet This type of appliance must be fitted inside a cabinet or inside another type of support structure. Before proceeding with cooker hood installation, remove grille D by pressing the two side buttons A, as shown in figure 3. Fix the appliance in place using 8 screws (not supplied) which are suited to the type of cabinet. Correctly, first fit the 4 screws A and then the 4 screws B, in accordance with the diagram in figure 4. After fixing the cooker hood to the lower part of the cabinet, place grille D (fig. Extraction through an outside wall The appliance expels the fumes through an outside wall or a duct. The acrylic filter, which is found resting on the grille, should be replaced when the text, visible through the grille, changes colour and the ink spreads; the new filter should be fitted in such a way that the text can be seen through the grille from outside the cooker hood. If the filters do not have any text on them, or if metal filters or aluminium panel filters are used, they should be washed every 2 months in order to prevent the risk of fire. To wash the filters, proceed as follows: - Remove the filter from the grille and wash it using a solution of water and neutral liquid detergent, leaving the dirt to soften. If the filters are made using aluminium, or if an aluminium panel is used, after a few washes the colour may change. If the replacement and washing instructions are not followed, the anti-grease filters may present a fire hazard. The active carbon filters are used to purify the air which is released back into the room. The filters are not washable or re-usable and must be replaced at least once every four months. The active carbon filter saturation level depends on the frequency with which the appliance is used, the type of cooking performed and the regularity with which the antigrease filters are cleaned. Remove build-up from the fan and other surfaces of the cooker hood regularly using a cloth moistened with denatured alcohol or non-abrasive neutral liquid detergent. C = SPEED I D = SPEED II E = SPEED III F = AUTOMATIC STOP TIMER - 15 minutes (*) If your appliance does not have the INTENSIVE speed function, press key E for two seconds and it will be activated for 10 minutes after which it will return to the previously set speed. By pressing key F for two seconds (with the hood switched off ) the "clean air" function is activated. [. . . ] This function switches the appliance on for ten minutes every hour at the first speed. As soon as this function is activated the motor starts up at the first speed for ten minutes, During this time key F and key C must flash at the same time. After ten minutes the motor switches off and the LED of key F remains switched on with a fixed light until the motor starts up again at the first speed after fifty minutes and keys F and C start to flash again for ten minutes and so on. By pressing any key for the exclusion of the hood light the hood will return immediately to its normal functioning (e. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANDY CBG62




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANDY CBG62 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.