[. . . ] Reversing devices are recommended for ALL installations.
AVERTISSEMENT
B
C2 WIRING TYPE WITH MONITORED SAFETY DEVICE
A
C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE (Factory Default)
ATTENTION
· Momentary contact to open and stop with constant pressure to close. · Open override that reverses when closing by any opening device. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) · Timer to Close (TTC) feature not available. [. . . ] MONITORED SAFETY DEVICE
NON-MONITORED SAFETY DEVICE
Sensing Edge
Photo Eye
TO PROGRAM Start with operator in factory default C2 mode. Press and hold the LEARN and CLOSE buttons until the LED goes out (approximately 3 seconds).
Electrical Box Logic Board
NO PROGRAMMING REQUIRED
D7 U4 D6
D5 D4
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
L5
AUX ANT AUX ANT
J2
^^^^ C18 R27 D14 K2 LT C29 R24 P1
LEARN
LEARN STOP CLOSE OPEN
3 4 5 6 7 COM INTRLK STOP CLOSE OPEN
STOP
CLOSE OPEN
TTC
LED
1 2
D9
LMEP1
LMEP2
D14 LED
1
2
3
4
5
6
7
3
BASIC PROGRAMMING
REMOTE CONTROLS
SINGLE BUTTON REMOTE CONTROL Built in 315 MHz radio receiver permits as many as 20 Security® remote controls or dip switch remote controls in any combination. Press and hold the button on the remote control until the LED flashes rapidly, then release to complete programming (LED will go out). Repeat steps 1 and 2 for additional remote controls.
Electrical Box Logic Board
TIMER TO CLOSE (TTC)
Timer to Close feature enables the operator to close from the open limit after a preset time, adjustable from 5 to 60 seconds. Every press and release of the STOP button will add 5 seconds to the Timer to Close. The TTC will become active after completion of the next open cycle.
NOTE: The LED does not indicate that timer is running.
1 2 3 4 5
OPEN
LEARN
D14 LED
D7 U4 D6 D5 D4
STOP
CLOSE OPEN
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
L5
AUX ANT AUX ANT
J2
^^^^ C18 R27 D14 K2 LT C29 R24 P1
TTC
LED
1 2
LEARN STOP CLOSE OPEN
3 4 5 6 7
6
7
D9
LMEP1
LMEP2
COM
INTRLK
STOP
CLOSE
OPEN
TO VERIFY TIMER TO CLOSE (TTC) SETTING 1. The LED will flash once per 5 seconds of timer setting.
Electrical Box Logic Board Timer To Close Button
MEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION
NOTE: The feature will use 3 of the 20 memory channels in the operator.
TTC
D14 LED
D7 U4 D6 D5 D4
LEARN
STOP
CLO
TO PROGRAM Open 1. Press and hold the desired button of the remote control until LED flashes rapidly, then release. TO ERASE ALL REMOTE CONTROLS Press and hold the LEARN button (over 5 seconds) until the LED goes out. All programmed remote controls will be erased.
Electrical Box Logic Board
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
L5
AUX ANT AUX ANT
J2
^^^^ C18 R27 D14 K2 LT C29 R24 P1
1
LEARN STOP CLOSE OPEN
3 4 5 6 7 COM INTRLK STOP CLOSE OPEN
2
3
4
5
TTC
LED
1 2
D9
LMEP1
LMEP2
LMEP1 LMEP2 COM INTRLK STOP CL
CLEAR THE TIMER TO CLOSE (TTC) 1. TIMER DEFEAT The TTC can be temporarily disabled by pressing a STOP button. TTC will become enabled after the next open command.
RADIO OPERATION
MODE OPEN CLOSE STOP REVERSE WHILE CLOSING TTC RESET
LEARN
D14 LED
D7 U4 D6 D5 D4
STOP
CLOSE OPEN
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
L5
AUX ANT AUX ANT
J2
^^^^ C18 R27 D14 K2 LT C29 R24 P1
TTC
LED
1 2
LEARN STOP CLOSE OPEN
3 4 5 6 7
1
2
3
4
5
6
7
D9
LMEP1
LMEP2
COM
INTRLK
STOP
CLOSE
OPEN
MEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
B2 B2 with TTC C2
X X X
X X (3 button remote)
X X X
X X X X WHEN OPEN
4
WARNING MANUAL DISCONNECT (MODELS MT/BMT & MH)
The operators have provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions for your model operator.
CAUTION
To prevent possible SERIOUS INJURY or DEATH from a falling door or arm: · DO NOT stand under the door arm when pulling the emergency release. · If possible, use emergency release handle to disengage trolley ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/ or unexpectedly. · NEVER use emergency release handle unless doorway is clear of persons and obstructions.
MODEL MT/BMT
Emergency Disconnect
TO DISCONNECT DOOR FROM OPENER
AVERTISSEMENT ATTENTION
Emergency Disconnect Door Arm
TO RECONNECT DOOR ARM TO TROLLEY Lift free end of door arm to trolley. Emergency disconnect will close.
Emergency Disconnect
Door Arm
NOTI C E
Pull emergency release handle straight down. Emergency disconnect will open.
Door
Emergency Release Handle
MODEL MH
These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. [. . . ] Contact your installing dealer.
MAINTENANCE SCHEDULE
Every 3 months or 5, 000 cycles repeat all tests in the Testing section. To locate a dealer in your area visit us online at www. liftmaster. com. The operator should be serviced at the following intervals: · Every 3 months or 5, 000 cycles · Every 6 months or 10, 000 cycles · Every 12 months or 20, 000 cycles
WARNING
To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing ANY maintenance.
CAUTION
AVERTISSEMENT
8
ATTENTION
O P E R AT O R N O T E S
9
O P E R AT O R N O T E S
10
O P E R AT O R N O T E S
11
OPEN
OPEN
ACCESSORIES
ENTRAPMENT PROTECTION DEVICES
REMOTE CONTROLS 315MHz 371LM
OPEN
1-Button SECURITY® Remote Control: Includes visor clip.
Monitored CPS-LN4
PRESS
Commercial Protector System®: Provides protection on doors up to 45' wide. NEMA-4 rated.
OPEN
R ING
TO
373LM
3-Button SECURITY® Remote Control: Includes visor clip. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN BMT5011E
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN BMT5011E will begin.