User manual CHAMBERLAIN CB24

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN CB24. We hope that this CHAMBERLAIN CB24 user guide will be useful to you.


CHAMBERLAIN CB24 : Download the complete user guide (9472 Ko)

You may also download the following manuals related to this product:

   CHAMBERLAIN CB24 MANUAL 2 (14850 ko)
   CHAMBERLAIN CB24 MANUAL 2 (14850 ko)

Manual abstract: user guide CHAMBERLAIN CB24

Detailed instructions for use are in the User's Guide.

[. . . ] ⷠA swinging gate shall NOT open into public access ways We recommend to use E-locks/Maglock against vandilism and if gate is installed where strong winds may appear. Extensioncable Kit 12m (page 6) Solar Panel 24 Volt Post bracket for round posts/piece Post bracket for gates opening to outside (push to open)/piece Battery Charger Supply . Warning - To reduce the risk of SEVERE INJURY or DEATH from an incorrect installation: Gate systems are comprised of many component parts. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. [. . . ] ⷠBEFORE installing power wiring or control stations be sure to follow all specifications and warnings described below. LA400-JB40 MOTOR EXTENSION CABLE KIT (OPTIONAL) Kit Contains: (1) 12m cable with terminals (1) Junction box IP65 (2) Strain reliefs PG 13, 5 (1) Mounting hardware In case no ground wire is available a ground rod must be installed. To reduce the risk of FIRE or INJURY to persons use only Chamberlain parts for replacement batteries. The batteries can be charged in circuit by using a charging transformer or solar panels. Batteries if installed function as back-up to open the gate in case of a power outage. Transformer must be removed from the backside of the control board if batteries are installed. POWER IN The 24Vac input can accept a charging transformer or the run transformer. Ideally the charge transformer is installed at the house and a low voltage line is used to the control board at the gate. SOLAR PANELS Optional solar panels may be used to charge the batteries. RED LED should be "Off" or indicate a fault to resolve (Example: Photocell activated or shortened wire). Red Edge for closing Red Edge/photo for opening Red Photo for opening Red Photo for closing Red Accessory current overload Red COM overload Red Timer to close run indicator Red Open gate command Red Open gate command Red Reset Function button Green Stop Button Green Logic board general power Green Shadow loop Green Interrupt loop Red Charger Overload Red Battery fuse open Red Accessory overload Red Gate 2 Limit indicator Red Gate 2 Limit indicator Red Gate 1 Limit indicator Red Gate 1 Limit indicator Red E-Lock/Maglock relay indicator Red Alarm/Flashing light relay indicator Green Diagnostic (see troubleshooting section) Red Transmitter learn indicators Red Open/Close programming indicator NOTE: When setting switches S2-5 the save switch must be in the off position prior to setting or changing switches for the change to be saved. Connect gate that opens first to terminal "Gate 1", the other to terminal "Gate 2". Repeat steps 1 and 2 until all remotes are programmed (50 remotes maximum total). Press LEARN XMITTER button (LED will light up) and hold until LED is off. NOTE: For highest level of security, we recommend the Rolling Code line of products. XMITTER button 2 will open both gates with one command from the remote control. Stop (N/C) - Stop only (does not reset alarm) SBC (Single Button Control) Input (N/O) This input will command the gate to OPEN !Open (N/O) - Opens only or reverses a closing gate Open Input and Exit Loop These terminals are intended for use as a general open control. Accessories such as telephone entry systems, radio receivers (open only applications), exit loop detectors, keypads and 7-day timers may be wired to this input. Shadow Loop Input Terminal and Common This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. Terminal P8 ­ Open Edge or Photo Eye If an Open Edge device or a Retro-Reflective Photo Eye has been connected to Terminal P8, then this input will reverse an opening gate for 2 seconds then stop. Activating this input with an Open Edge device or a Retro-Reflective Photo Eye connected to Terminal P8 while the gate is closing will have no effect. [. . . ] ® Check the Open Loop area to ensure all obstructions are removed. If an external opening device or entry or entry system is attached, check for proper operation of that system. GATE WON'T STAY OPEN WHEN USING FIRE INPUT Fire Input switch should be a constant contact key switch connected to Open Loop input (Open only). ® Check the gate area to make sure all obstructions are removed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN CB24




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN CB24 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.