[. . . ] DIAL CODE SERIES
O W N E R S M A N U A L
Telephone entry systems with two line large LC or VF displays
with
BUILT-IN surge suppression
VISIT US ON THE WEB
www. chamberlain. com
TABLE OF CONTENTS
Product Overview . 38
To be installed by Qualified Dealers ONLY!
LC/VF manual
Version 3. 0
LC/VF Page
1
PRODUCT OVERVIEW
STANDARD FEATURES
· Two line LC or VF Directory. · User-friendly programmability via built-in alpha-numeric keyboard eliminates the need for user's manual. · Four character alpha-numeric password required to enter programming mode. [. . . ] 1. 00_
(fig e. ) Software Version Number
20
WARNINGS AND PRECAUTIONS
25
0
500
Do not touch the terminals on the RAM Cards. Do not bend, drop or expose to impact.
3 2 1 4 7 U Y T R E W Q A
SHIF T BA R
6 5 8 0 I O L K J H M N
CK BAACE SP
9 P
HEL ENT
PROG RAM
P
ER
'
EX ERA SE
T
G F B V C
D S X Z
S
E PAC
The Telephone Entry System is only water resistant when the Stainless Steel Door is closed and locked. Do not expose the Processor Unit or the open Processor Containment Box to rain, snow, or harsh weather conditions. Do not drop the Processor or expose it to impact.
LC/VF Page
21
PROGRAMMING THE PROCESSOR
ENTERING THE PROGRAM MODE
When the Processor unit is turned on and the
button is pressed, the screen will display:
TO ENTER PROG MODE, Type Password >____
Type in the factory present password (7777). The Program Selection Screen
SELECT PROG MODE: (N)Names (U)Utility
If you enter the wrong password, the screen will prompt you to try again:
INVALID PASSWORD (R)Retry (EXIT)Quit
Press
R
to retry entering your password. Press
to quit the programming menu.
Pressing the
button will provide users with a help message.
IMPORTANT NOTE: While in the help screens, programming will be disabled. To continue programming, press the button to exit the help screens first.
LC/VF Page
22
SELECTING PROGRAM MODE
LIST OF PROGRAM MODES:
1 2 3 4 5 6 7 8 9 Names Utility Password* Clock/Timer Strike Time Talk TIme Greeting Volume Backup N U P C S T G V B Program or edit Resident Names Program or edit Utility Codes Program New Password ( recommended ) Program System Clock and Seven Day Timers Program relay output time ( for 2 relays ) Program length of Talk Time Program custom Welcome Screen Message Program Volume level Backup of memory card page 24-26 page 27 page 28 pages 29-31 page 32 page 32 page 33 page 33 page 34
*We recommend you customize your password to avoid unauthorized programming (see "Password" section) To select a Program Mode, press the corresponding letter from one of the nine options.
Use the
keys to scroll through the nine different Program Modes.
SELECT PROG MODE: (N)Names (U)Utility SELECT PROG MODE: (P)Password SELECT PROG MODE: (C)Clock/Timer
SELECT PROG MODE: (S)Strike Time SELECT PROG MODE: (T)Talk Time SELECT PROG MODE: (G)Greeting
SELECT PROG MODE: (V)Volume (B)Backup
Pressing the button will provide users with a help message.
IMPORTANT NOTE: While in the help screens, programming will be disabled. To continue programming, press the button to exit the help screens first.
LC/VF Page
23
RESIDENT INFORMATION
STEP
1
In the Program Selection Screen (fig a. ), Press the
N
key. The screen will display (fig b. ):
SELECT PROG MODE: (N)Names (U)Utility
(fig a. ) STEP
PROG A NEW NAME PROG BY CODE:___
N
(fig b. )
2
N
You now have three options: To program by code, enter To view or edit an existing name
To program by name, press the key and the first
OR
a three digit code* and press the key.
OR
or code, use the keys to scroll through Directory.
empty code will display.
* The unit will only accept codes within it's
range - depending on memory capacity.
STEP
3
Type in the desired Resident name, LAST name first, followed by the first name (fig c. ). If the code you have selected is already used, there will be a name already. You may also use the keys to move the cursor
Resident code
005 LastNAME, First Jones, Robert_
Resident name (example - fig c. )
005 PHONE NUMBER: _-___-496-2634
(example - fig d. )
STEP
4 5
Type in the desired Resident phone number (fig d. ). (fig e. )
STEP
An individual six digit Resident Key code may be assigned to each resident . Residents can use their Key Code to access the premises.
005 KEY CODE: 005123
(example - fig e. )
Assignment of Resident Key Codes is optional. The first three digits of the Key Code is the assigned Directory Code. Assign the last three digits (numeric characters only) to create an individual Key Code. Press the
LC/VF Page
key.
24
TRANSMITTER/CARD PROGRAMMING
STEP
6
To complete entry, press the
key to return to the program selection screen.
To program RF devices ( i. e. NOTE: To enable the transmitter/card programming feature, you must insert the communicator card in the "backup" slot before you turn on unit. (refer to "Memory Card Installation" section)
STEP
7
Use
keys to view and
program up to 10 transmitter or card codes associated to the directory code.
005 TRANSM/CARD#1: ___-_____ (S) SCAN 005 TRANSM/CARD#2: ___-_____ (S) SCAN
· · · ·
To program a transmitter or card code you may enter the code manually using the keypad or you may scan the transmitter/card code.
STEP
8
To scan a card code, press and release the
005 TRANSM/CARD#10: ___-_____ (S) SCAN
Touch the card to the card reader to activate remote device Model ECR485B (fig a. )
S
key and activate the card
as shown in fig a. To scan a transmitter code, press and release the
S
key and activate
the transmitter as shown in fig b.
1 4 7
ERASE EX T
PROGRAM
2 5 8 0
3 6 9
ENTER
HELP
(fig b. )
I O K M L P
Q
SHIFT
W A Z S
E D X
R F C
T G V
Y H B
U J N
SPACE BAR
'
BACK SPACE
Processor
STAND-ALONE RECEIVER Model ERRB485 Press button on transmitter to activate remote device
STEP
9
Repeat steps 7 and 8 for up to ten devices per directory code. After the last device has been programmed, press or key to return to the program selection screen.
NOTE: The time zones and restrictions associated with transmitter/card codes can only be programmed remotely using the
EMS modem software.
LC/VF Page
25
AREA CODES
005 PHONE NUMBER: _-___-___-____
PREFIX FIELD AREA CODE FIELD (fig a. )
In special applications, it is necessary to enter area codes for Resident Phone Numbers. Area codes are entered from the Phone Number screen (fig a. ).
005 PHONE NUMBER: 1-___-___-____
(fig b. )
Use the
key to enter the area code and prefix field (fig b. ). To choose 8, 9, or 10-digit dialing, when no prefix is needed, press while in the prefix field. [. . . ] (fig a. ) Codes that cannot be accessed by the limitation of the system being used cannot be edited.
Codes Detected out of Range, See Manual
(fig a. )
LOW BATTERY If the battery backup is reaching it's minimal charge level, a battery icon with a "B" next to it will display in the top right corner of the display. The batteries must be charged to continue. * If the battery backup level reaches it's minimal charge, an error message will display (fig c. ) and the system will become non-functional until the battery backup is charged by using the plug in transformer. *
WELCOME
B
(fig b. )
Battery Is Low It Must Be Recharged
(fig c. )
LOW BATTERY ICONS: If a battery icon appears in the top right corner of the display and the letter next to it is an "M" or a "C", as shown in (fig d. ) and (fig e. ), contact Manufacturer for instructions.
WELCOME
C
(fig d. )
WELCOME
M
(fig e. )
*IMPORTANT NOTE: In order to charge the battery in the Dial Code System, the processor MUST be plugged in to the transformer and the processor MUST BE ON. If the power is off on the processor, the battery will not be charging.
LC/VF Page
35
LC ILLUSTRATION & PARTS LIST
T010 T009 T035
T060 T033 T011
TEL L NE
Remote Access RS-485
TIP RING (+) () GND (+) () GND (+) () GND (+) () GND CHASS S GROUND
12V AC/DC
POWER INPUT
COMMUNIC TOR CARD
RS 485 (1)
capacity
RS 485 (2)
El te Entry Phone
DOOR NO DOOR NC DOOR C GATE NO GATE NC GATE C
DOOR RELAY GATE RELAY
T031 T037 T003 T029 T002
Memory Card T020 T030
RS485 Card
RS 485 3)
VCR NO VCR C GND INPUT
VCR RELAY
POSTAL/EXIT SW INPUT
5 4)
T027
LC Processor
T044 T014SPT
T025
T012SPT
T032 T000
T026
LC Part #
T000 T002 T003 T009 T010 T011 T012SPT T014SPT T020 T025 T026 T027 T029 T030 T031 T032
LC Description
Transformer 12 Vac 50VA (Provided) External Keypad Keylock Processor Containment Box (Back Box) Processor Key Release / Lock Battery Back-Up 9-Pin Comm Port Connector (Surge Protection Terminal) External Box Connection Kit (Surge Protection Terminal) LC Complete Internal Metal Box (Processor Box) Programming Keys Postal Lock Assembly LCD Processor - No Memory Card Key for Internal / External Lock LCD Display Kit for Keypad Light Phone Control Board (Inside Processor)
LC Part #
T033 T035 T036 T037 T044 T060 T25MEM T50MEM T150MEM T250MEM T500MEM T1000MEM RFCARD4K RFCARD8K RFCARD16K
LC Description
LCD Display Window LC External Box Assembly Heater Pad Option (Pre-Installed in Processor) Keypad Light Speaker 4 OHM Dial Code Surge Protection Board 25 Name Memory Card 50 Name Memory Card 150 Name Memory Card 250 Name Memory Card 500 Name Memory Card 1000 Name Memory Card RS485 Communicator Card 4000 RS485 Communicator Card 8000 RS485 Communicator Card 16000
All components and specifications are subject to change without notice.
LC/VF Page
36
VF ILLUSTRATION & PARTS LIST
T010 T009 T034 T008 T005 T007 T060 T004 T011 T006
TEL L NE
Remote Access RS-485
TP RING (+) () GND (+) () GND (+) () GND (+) () GND CHASSIS GROUND
12V AC DC
POWER INPUT
COMMUN CATOR CARD
RS 485 1)
capacity
RS 485 2)
El te Entry Phone
Memory Card T019 T018
RS485 Card
DOOR NO DOOR NC DOOR C GATE NO GATE NC GATE C
DOOR RELAY GATE RELAY
T031 T037 T003 T029 T002
RS 485 3)
VCR NO VCR C GND NPUT
VCR RELAY
POSTAL EX T SW INPUT
485 4
T028
VF Processor
T044 T014SPT
T025 T012SPT
T032
T000
T026
VF Part #
T000 T002 T003 T004 T005 T006 T007 T008 T009 T010 T011 T012SPT T014SPT T018 T019 T025 T026 T028
VF Description
Transformer 12 Vac 50VA (Provided) External Keypad Keylock Display Window Glass Only (VF) Display Window Metal Bracket (VF) Display Window Glass and Bracket (VF) Display Hood (VF) Stainless Steel Door (VF) Processor Containment Box (Back Box) Processor Key Release / Lock Battery Back-Up 9-Pin Comm Port Connector (Surge Protection Terminal) External Box Connection Kit (Surge Protection Terminal) Vacuum Florescent Display VF Complete Internal Metal Box (Processor Box) Programming Keys Postal Lock Assembly VFD Processor - No Memory Card
VF Part #
T029 T031 T032 T034 T036 T037 T044 T060 T25MEM T50MEM T150MEM T250MEM T500MEM T1000MEM RFCARD4K RFCARD8K RFCARD16K
VF Description
Key for Internal / External Lock Kit for Keypad Light Phone Control Board (Inside Processor) VF External Box Assembly Heater Pad Option (Pre-Installed in Processor) Keypad Light Speaker 4 OHM Dial Code Surge Protection Board 25 Name Memory Card 50 Name Memory Card 150 Name Memory Card 250 Name Memory Card 500 Name Memory Card 1000 Name Memory Card RS485 Communicator Card 4000 RS485 Communicator Card 8000 RS485 Communicator Card 16000
All components and specifications are subject to change without notice.
LC/VF Page
37
APPROVALS
The Chamberlain Group, Inc.
Complies with Part 68, FCC Rules
FCC Part 15 - Tested to comply with FCC standards for home or office use
This Class B digital apparatus meets all requirements of CANADIAN Interference Causing Equipment Regulations.
UL STD 294, 5th Ed. UL STD 1950, 3rd Ed.
Instruction to the User: This equipment has been tested and found to comply with the limits for a class 13 digital device, pursuant to part 15 of the FCC Rules. [. . . ]