User manual CHAMBERLAIN DIAL CODE LC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN DIAL CODE LC. We hope that this CHAMBERLAIN DIAL CODE LC user guide will be useful to you.


CHAMBERLAIN DIAL CODE LC : Download the complete user guide (3480 Ko)

You may also download the following manuals related to this product:

   CHAMBERLAIN DIAL CODE LC MANUAL 2 (957 ko)
   CHAMBERLAIN DIAL CODE LC INSTALLATION (91 ko)

Manual abstract: user guide CHAMBERLAIN DIAL CODE LC

Detailed instructions for use are in the User's Guide.

[. . . ] DIAL CODE SERIES O W N E R S M A N U A L Telephone entry systems with two line large LC or VF displays with BUILT-IN surge suppression VISIT US ON THE WEB www. chamberlain. com TABLE OF CONTENTS Product Overview . 38 To be installed by Qualified Dealers ONLY! LC/VF manual Version 3. 0 LC/VF Page 1 PRODUCT OVERVIEW STANDARD FEATURES · Two line LC or VF Directory. · User-friendly programmability via built-in alpha-numeric keyboard eliminates the need for user's manual. · Four character alpha-numeric password required to enter programming mode. [. . . ] 1. 00_ (fig e. ) Software Version Number 20 WARNINGS AND PRECAUTIONS 25 0 500 Do not touch the terminals on the RAM Cards. Do not bend, drop or expose to impact. 3 2 1 4 7 U Y T R E W Q A SHIF T BA R 6 5 8 0 I O L K J H M N CK BAACE SP 9 P HEL ENT PROG RAM P ER ' EX ERA SE T G F B V C D S X Z S E PAC The Telephone Entry System is only water resistant when the Stainless Steel Door is closed and locked. Do not expose the Processor Unit or the open Processor Containment Box to rain, snow, or harsh weather conditions. Do not drop the Processor or expose it to impact. LC/VF Page 21 PROGRAMMING THE PROCESSOR ENTERING THE PROGRAM MODE When the Processor unit is turned on and the button is pressed, the screen will display: TO ENTER PROG MODE, Type Password >____ Type in the factory present password (7777). The Program Selection Screen SELECT PROG MODE: (N)Names (U)Utility If you enter the wrong password, the screen will prompt you to try again: INVALID PASSWORD (R)Retry (EXIT)Quit Press R to retry entering your password. Press to quit the programming menu. Pressing the button will provide users with a help message. IMPORTANT NOTE: While in the help screens, programming will be disabled. To continue programming, press the button to exit the help screens first. LC/VF Page 22 SELECTING PROGRAM MODE LIST OF PROGRAM MODES: 1 2 3 4 5 6 7 8 9 Names Utility Password* Clock/Timer Strike Time Talk TIme Greeting Volume Backup N U P C S T G V B Program or edit Resident Names Program or edit Utility Codes Program New Password ( recommended ) Program System Clock and Seven Day Timers Program relay output time ( for 2 relays ) Program length of Talk Time Program custom Welcome Screen Message Program Volume level Backup of memory card page 24-26 page 27 page 28 pages 29-31 page 32 page 32 page 33 page 33 page 34 *We recommend you customize your password to avoid unauthorized programming (see "Password" section) To select a Program Mode, press the corresponding letter from one of the nine options. Use the keys to scroll through the nine different Program Modes. SELECT PROG MODE: (N)Names (U)Utility SELECT PROG MODE: (P)Password SELECT PROG MODE: (C)Clock/Timer SELECT PROG MODE: (S)Strike Time SELECT PROG MODE: (T)Talk Time SELECT PROG MODE: (G)Greeting SELECT PROG MODE: (V)Volume (B)Backup Pressing the button will provide users with a help message. IMPORTANT NOTE: While in the help screens, programming will be disabled. To continue programming, press the button to exit the help screens first. LC/VF Page 23 RESIDENT INFORMATION STEP 1 In the Program Selection Screen (fig a. ), Press the N key. The screen will display (fig b. ): SELECT PROG MODE: (N)Names (U)Utility (fig a. ) STEP PROG A NEW NAME PROG BY CODE:___ N (fig b. ) 2 N You now have three options: To program by code, enter To view or edit an existing name To program by name, press the key and the first OR a three digit code* and press the key. OR or code, use the keys to scroll through Directory. empty code will display. * The unit will only accept codes within it's range - depending on memory capacity. STEP 3 Type in the desired Resident name, LAST name first, followed by the first name (fig c. ). If the code you have selected is already used, there will be a name already. You may also use the keys to move the cursor Resident code 005 LastNAME, First Jones, Robert_ Resident name (example - fig c. ) 005 PHONE NUMBER: _-___-496-2634 (example - fig d. ) STEP 4 5 Type in the desired Resident phone number (fig d. ). (fig e. ) STEP An individual six digit Resident Key code may be assigned to each resident . Residents can use their Key Code to access the premises. 005 KEY CODE: 005123 (example - fig e. ) Assignment of Resident Key Codes is optional. The first three digits of the Key Code is the assigned Directory Code. Assign the last three digits (numeric characters only) to create an individual Key Code. Press the LC/VF Page key. 24 TRANSMITTER/CARD PROGRAMMING STEP 6 To complete entry, press the key to return to the program selection screen. To program RF devices ( i. e. NOTE: To enable the transmitter/card programming feature, you must insert the communicator card in the "backup" slot before you turn on unit. (refer to "Memory Card Installation" section) STEP 7 Use keys to view and program up to 10 transmitter or card codes associated to the directory code. 005 TRANSM/CARD#1: ___-_____ (S) SCAN 005 TRANSM/CARD#2: ___-_____ (S) SCAN · · · · To program a transmitter or card code you may enter the code manually using the keypad or you may scan the transmitter/card code. STEP 8 To scan a card code, press and release the 005 TRANSM/CARD#10: ___-_____ (S) SCAN Touch the card to the card reader to activate remote device Model ECR485B (fig a. ) S key and activate the card as shown in fig a. To scan a transmitter code, press and release the S key and activate the transmitter as shown in fig b. 1 4 7 ERASE EX T PROGRAM 2 5 8 0 3 6 9 ENTER HELP (fig b. ) I O K M L P Q SHIFT W A Z S E D X R F C T G V Y H B U J N SPACE BAR ' BACK SPACE Processor STAND-ALONE RECEIVER Model ERRB485 Press button on transmitter to activate remote device STEP 9 Repeat steps 7 and 8 for up to ten devices per directory code. After the last device has been programmed, press or key to return to the program selection screen. NOTE: The time zones and restrictions associated with transmitter/card codes can only be programmed remotely using the EMS modem software. LC/VF Page 25 AREA CODES 005 PHONE NUMBER: _-___-___-____ PREFIX FIELD AREA CODE FIELD (fig a. ) In special applications, it is necessary to enter area codes for Resident Phone Numbers. Area codes are entered from the Phone Number screen (fig a. ). 005 PHONE NUMBER: 1-___-___-____ (fig b. ) Use the key to enter the area code and prefix field (fig b. ). To choose 8, 9, or 10-digit dialing, when no prefix is needed, press while in the prefix field. [. . . ] (fig a. ) Codes that cannot be accessed by the limitation of the system being used cannot be edited. Codes Detected out of Range, See Manual (fig a. ) LOW BATTERY If the battery backup is reaching it's minimal charge level, a battery icon with a "B" next to it will display in the top right corner of the display. The batteries must be charged to continue. * If the battery backup level reaches it's minimal charge, an error message will display (fig c. ) and the system will become non-functional until the battery backup is charged by using the plug in transformer. * WELCOME B (fig b. ) Battery Is Low It Must Be Recharged (fig c. ) LOW BATTERY ICONS: If a battery icon appears in the top right corner of the display and the letter next to it is an "M" or a "C", as shown in (fig d. ) and (fig e. ), contact Manufacturer for instructions. WELCOME C (fig d. ) WELCOME M (fig e. ) *IMPORTANT NOTE: In order to charge the battery in the Dial Code System, the processor MUST be plugged in to the transformer and the processor MUST BE ON. If the power is off on the processor, the battery will not be charging. LC/VF Page 35 LC ILLUSTRATION & PARTS LIST T010 T009 T035 T060 T033 T011 TEL L NE Remote Access RS-485 TIP RING (+) () GND (+) () GND (+) () GND (+) () GND CHASS S GROUND 12V AC/DC POWER INPUT COMMUNIC TOR CARD RS 485 (1) capacity RS 485 (2) El te Entry Phone DOOR NO DOOR NC DOOR C GATE NO GATE NC GATE C DOOR RELAY GATE RELAY T031 T037 T003 T029 T002 Memory Card T020 T030 RS485 Card RS 485 3) VCR NO VCR C GND INPUT VCR RELAY POSTAL/EXIT SW INPUT 5 4) T027 LC Processor T044 T014SPT T025 T012SPT T032 T000 T026 LC Part # T000 T002 T003 T009 T010 T011 T012SPT T014SPT T020 T025 T026 T027 T029 T030 T031 T032 LC Description Transformer 12 Vac 50VA (Provided) External Keypad Keylock Processor Containment Box (Back Box) Processor Key Release / Lock Battery Back-Up 9-Pin Comm Port Connector (Surge Protection Terminal) External Box Connection Kit (Surge Protection Terminal) LC Complete Internal Metal Box (Processor Box) Programming Keys Postal Lock Assembly LCD Processor - No Memory Card Key for Internal / External Lock LCD Display Kit for Keypad Light Phone Control Board (Inside Processor) LC Part # T033 T035 T036 T037 T044 T060 T25MEM T50MEM T150MEM T250MEM T500MEM T1000MEM RFCARD4K RFCARD8K RFCARD16K LC Description LCD Display Window LC External Box Assembly Heater Pad Option (Pre-Installed in Processor) Keypad Light Speaker 4 OHM Dial Code Surge Protection Board 25 Name Memory Card 50 Name Memory Card 150 Name Memory Card 250 Name Memory Card 500 Name Memory Card 1000 Name Memory Card RS485 Communicator Card 4000 RS485 Communicator Card 8000 RS485 Communicator Card 16000 All components and specifications are subject to change without notice. LC/VF Page 36 VF ILLUSTRATION & PARTS LIST T010 T009 T034 T008 T005 T007 T060 T004 T011 T006 TEL L NE Remote Access RS-485 TP RING (+) () GND (+) () GND (+) () GND (+) () GND CHASSIS GROUND 12V AC DC POWER INPUT COMMUN CATOR CARD RS 485 1) capacity RS 485 2) El te Entry Phone Memory Card T019 T018 RS485 Card DOOR NO DOOR NC DOOR C GATE NO GATE NC GATE C DOOR RELAY GATE RELAY T031 T037 T003 T029 T002 RS 485 3) VCR NO VCR C GND NPUT VCR RELAY POSTAL EX T SW INPUT 485 4 T028 VF Processor T044 T014SPT T025 T012SPT T032 T000 T026 VF Part # T000 T002 T003 T004 T005 T006 T007 T008 T009 T010 T011 T012SPT T014SPT T018 T019 T025 T026 T028 VF Description Transformer 12 Vac 50VA (Provided) External Keypad Keylock Display Window Glass Only (VF) Display Window Metal Bracket (VF) Display Window Glass and Bracket (VF) Display Hood (VF) Stainless Steel Door (VF) Processor Containment Box (Back Box) Processor Key Release / Lock Battery Back-Up 9-Pin Comm Port Connector (Surge Protection Terminal) External Box Connection Kit (Surge Protection Terminal) Vacuum Florescent Display VF Complete Internal Metal Box (Processor Box) Programming Keys Postal Lock Assembly VFD Processor - No Memory Card VF Part # T029 T031 T032 T034 T036 T037 T044 T060 T25MEM T50MEM T150MEM T250MEM T500MEM T1000MEM RFCARD4K RFCARD8K RFCARD16K VF Description Key for Internal / External Lock Kit for Keypad Light Phone Control Board (Inside Processor) VF External Box Assembly Heater Pad Option (Pre-Installed in Processor) Keypad Light Speaker 4 OHM Dial Code Surge Protection Board 25 Name Memory Card 50 Name Memory Card 150 Name Memory Card 250 Name Memory Card 500 Name Memory Card 1000 Name Memory Card RS485 Communicator Card 4000 RS485 Communicator Card 8000 RS485 Communicator Card 16000 All components and specifications are subject to change without notice. LC/VF Page 37 APPROVALS The Chamberlain Group, Inc. Complies with Part 68, FCC Rules FCC Part 15 - Tested to comply with FCC standards for home or office use This Class B digital apparatus meets all requirements of CANADIAN Interference Causing Equipment Regulations. UL STD 294, 5th Ed. UL STD 1950, 3rd Ed. Instruction to the User: This equipment has been tested and found to comply with the limits for a class 13 digital device, pursuant to part 15 of the FCC Rules. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN DIAL CODE LC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN DIAL CODE LC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.