User manual CHAMBERLAIN EGJ

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN EGJ. We hope that this CHAMBERLAIN EGJ user guide will be useful to you.


CHAMBERLAIN EGJ : Download the complete user guide (1326 Ko)

Manual abstract: user guide CHAMBERLAIN EGJ

Detailed instructions for use are in the User's Guide.

[. . . ] FACTORYSET C2 Wiring See page 7 for other wiring configurations OWNER'S MANUAL EGJ EUROPEAN STYLE GEARHEAD DAMP ENVIRONMENT JACKSHAFT TH E C EL HA MH MB UR ER ST, LA IL IN G LIN R OIS OU 60 P, IN 12 C. 6 41 B6 PL LIS AC E RA TI NG LA BE L HE RE TE D DO OR OP ER AT OR 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE Serial # Box Installation Date Wiring Type TABLE OF CONTENTS SPECIFICATIONS Operator Specifications . . 9 WARNING Mechanical CAUTION WARNING Electrical IMPORTANT NOTES: · BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. · DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician. WARNING WARNING WARNING WARNING WARNING CAUTION When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. [. . . ] A compression gland nut, when provided as part of a fitting, will typically achieve maximum securement. Ensure conduit jacket is not cut or ripped in any location along its surface. NOTE: For conduit preparation, always follow the conduit manufacturer's instructions. CIA CONDUIT & FITTINGS ADVERTENCIA ADVERTENCIA entry hole to be placed in enclosure and Liquid tight Flexible Non-metalics Conduit (LFNC) is required for 1. Select proper fitting use in both exposed and concealed areas and for electrical systems that require flexibility and protection from vapors, liquids or solids. LFNC conduit should be used for liquid tight environment as stated by NEMA guidelines. All conduit and conduit fittings should be marked as "Liquid Tight" conduit and fittings marked "Rain Tight" or "Wet Locations" are not to be automatically considered liquid tight. NOTE: Select all conduit and conduit connectors based on local code and application of job. Insert gasket around threaded area and secure in place with nut provided. (Refer to manufacturer specifications for proper torque requirements. ) 4. Remove all resulting debris created by entry hole(s) otherwise electrical components and operation may be affected. TH E C EL HA M MB HU E RS RLA T, IL IN G LI NO ROU I S P, 6 0 IN 12 C. 6 ATTACHMENT TO ENCLOSURE N WARNING Do Not Run Power & Control Wiring in the Same Conduit 7 41 B6 PL AC ER LI ST ED AT I NG LA B EL H DO OR ER E OP ER AT OR CONTROL WIRING DETERMINE WIRING TYPE Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring. WIRING TYPES Standard C2 or B2 Wiring Standard operators are shipped from the factory with jumper set for C2 wiring, which requires constant pressure on button to close the door. If momentary contact on close direction is desired (B2 wiring) you must include an entrapment protection device. Constant pressure on close (C2 wiring) Red jumper wire was placed on terminal #2 in electrical enclosure. The operator will require constant pressure on close control in order to keep door moving in the close direction. Momentary contact on close (B2 wiring) Move red jumper wire from terminal #2 to terminal #3. The operator will require only momentary contact to close the door. SPECIAL CONTROL WIRING If your operator was shipped from the factory with non-standard control wiring or with optional accessories that require addition instructions, refer to the wiring diagram(s) indicated in the special control wiring data box. When a replacement wiring diagram is present, wiring diagrams in this manual will not apply. IMPORTANT NOTE: If your wiring diagram is missing, or you are unsure of the wiring type for your operator, contact technical support @ 1-800-528-2806 or www. liftmaster. com. LOCATING THE CONTROL STATION All operators are provided with a 3-Button Station (OPEN/CLOSE/STOP) incorporated into the wall mounted starter. Mount the wall mounted starter where the door is visible, but away from the door and its hardware. Mount control station(s) within line on sight of door(s). WARNING To prevent possible SERIOUS INJURY or DEATH, install reversing sensors when the 3-button control station is out of sight of the door or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. CAUTION TH E C EL HA M MB HU E RS RLA T, IL IN G LI NO ROU I S P, 6 0 IN 12 C. 6 AVERTISSEMENT ATTENTION OPEN 41 B6 WARNING CLOSE TO R PL AC ER LI ST ED AT I NG LA B EL H DO OR ER E OP ER A TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR WARNING Notice 8 CONTROL WIRING RADIO CONTROLS On all models with type B2 control wiring, a terminal block marked R1 R2 R3 is located on the inside of the wall connected starter. [. . . ] · ALL electrical connections MUST be made by a qualified individual. · DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that you install an optional reversing edge BEFORE proceeding with the control station installation. · ALL power wiring should be on a dedicated circuit and well protected. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN EGJ




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN EGJ will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.