If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN HCT 501130. We hope that this CHAMBERLAIN HCT 501130 user guide will be useful to you.
Manual abstract: user guide CHAMBERLAIN HCT 501130
Detailed instructions for use are in the User's Guide.
[. . . ] TABLE OF CONTENTS
Features and Specifications Role of Specifiers and Designers Role of Dealers, Installers and Trained System Technicians UL Gate Classifications Role of End Users Overhead Gate / Door Systems Safety Installation Instructions Steps 1-2 Installation of Operator Steps 3-5 Mounting the Operator Step 6 How to Connect Power (120 Vac) Earth Ground Rod Step 7 Mounting and Wiring of the Reset Switch Step 8 Adjusting the Traveling Distance (Limit Switches) Step 9 Two Way Adjustable Reversing Sensor Step 10 Adjustable Timer Step 11 Terminal Input Connections Steps 12-13 IMPORTANT INFORMATION Operating Instructions for Optional Systems Three Push Button System House Alarm / Proximity Switch Connections Optional Relay Adapter Connection Secondary Entrapment Protection (Contact Sensor) Secondary Entrapment Protection (Non-Contact Sensor) Optional Plug-In Loop Detectors Wiring External Loop Detectors Programming the Radio Receiver Replacing the Control Board Audio Alarm Important Safety Instructions MANUAL RELEASE Troubleshooting Table Troubleshooting / LED Information Parts Illustrations Parts List Maintenance Accessories Operator Notes 2 3 3 4 5 5 6 7 8 9 10 11 12 12 13 14 15 15 16 17 18 19 20 21 22-23 24 24 25 26 27 28 29 30 30 31 32
MAINTENANCE & OPERATION
INSTA LLA TIO N
Important: DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician.
For Toll Free Technical Support: 1-800-528-2806 www. liftmaster. com
1
FEATURES AND SPECIFICATIONS
141" 8. 25" 22. 01"
VARIABLE OPERATING LENGTHS Door Height Operator Length 8 ft. Door 189 in.
4" 18. 875"
8. 36"
CONTINUOUS CYCLE 240 LBS. PULL COMMERCIAL DOOR AND GATE OPERATOR
1/2 HP 120 VAC 1PH 60HZ 4. 8 AMPS WEIGHT 123 LBS
MOTOR - 120VAC 4. 8 Amp 1/2 HP instant reversing parking gate Leeson Motor GEAR BOX - 40 to 1 ratio, lubrication by oil bath gives smooth, quiet operation and features positive gate locking. NOISE ISOLATOR - Heavy duty rubber attachments isolate vibration, absorb shock and eliminate noise. [. . . ] The location of the power disconnect should be visible and clearly labeled. · ALL power and control wiring must be run in separate conduit. · BEFORE installing power wiring or control stations, be sure to follow ALL specifications and warnings described below. Failure to do so may result in SEVERE INJURY to persons and/or damage to operator. · Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate/door.
Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from which to dissipate its energy safely into the earth. Without this path, the intense energy generated by lightning could be directed towards the operator. Although nothing can absorb the tremendous power of a direct lightning strike, proper grounding can protect the operator in most cases. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length. In certain circumstances, metal water pipes may be allowed for grounding the operator. Check and follow all local codes for proper grounding procedures.
CAUTION: To avoid damaging gas, power, or other underground utility lines, contact local underground utility locating companies before digging.
Minimum 12 Gauge Ground Wire connected to HCT Earth Ground Wire Black = 120 Vac Wire White = Neutral Wire Green = Earth Ground Wire Use UL Listed conduit to enclose power wires
Chamberlain Professional Products is not responsible for improper installation or failure to comply with all necessary local building codes.
9
MOUNTING AND WIRING OF RESET SWITCH
STEP 7
The reset switch allows the operator to be reset upon the event of a double entrapment alarm. When such an event occurs the alarm will continuously sound and the operator will not have any functionality until the board is reset. Mount reset switch at a minimum of 6' away from the gate/door jambs (Figure 1). Plug the interface cable (Figure 2) into the J5 receptacle on the Omni control board (Figure 3). NOTE: The wire connecting the interface cable to the reset switch is not provided.
WARNING
To prevent possible SERIOUS INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing. ALL electrical connections MUST be made by a qualified individual.
Figure 1
RESET
6' min.
RESET
Figure 2
CENTER
SAFETY
EXIT
Figure 3
DC-BACKUP
QCC
SENSOR ALARM
Plug Reset Switch Connector to J5 Connector
J5
DC-BACKUP
W4 GBA
OPEN A B MAGLOCK ALARM ARMED M / S L I NK
MS STOP LINK CLOSE
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN CLOSE STOP
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
10
ADJUSTING TRAVELING DISTANCE
STEP 8
Before Adjusting, Do the Following:
1. If further adjustment is needed, repeat the process.
Push Plate
11
2-WAY ADJUSTABLE REVERSING SENSOR
STEP 9
Adjusted by Qualified Service Personnel
CENTER
SAFETY
EXIT
3
1
3
DC-BACKUP
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
SENSOR ALARM
REVERSE SENSOR
Maximum Sensitivity
MADE IN USA
1
3
1
3
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
DO NOT TOUCH ALARM SENSOR
The level of reverse sensitivity has to do with the weight of the gate/door and the condition of installation. Not sensitive enough = If the gate/door hits an obstruction or vehicle and does not stop or reverse.
ADJUSTABLE TIMER
STEP 10
TIMER
CENTER SAFETY EXIT
CLOSE
Minimum Sensitivity
EXIT
STOP
Timer ON
60 3
Set Timer Decrease Time
NSOR
OFF
OPEN LEFT
ON
1
3
OPEN RIGHT
DC-BACKUP
SENSOR ALARM
W4 GBA
MS LINK
Increase Time TIMER
NSOR
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
60
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
CLOSE
STOP
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
OFF
OPEN LEFT
1
3
ON
OPEN RIGHT
Timer can be set from 1 to 60 seconds (Timer ON), For push open/push close type operation (Timer OFF).
Timer OFF
12
DC-BACKUP
TERMINAL INPUT CONNECTIONS
GBA
MS LINK
W4
SENSORS
SYSTEM ON
TIMER
60
3
POWER OVERLOAD
OPEN
REVERSE SENSOR
Important: Terminals 11 and 12 are the only terminals that will both Open and/or Close with OFF ON a single push of a button. All other terminals will only open with a single push of a button.
ALARM SENSOR
1 3
1
3
1
3
OPEN LEFT
OPEN RIGHT
COMMAND PROCESSED
CENTER SAFETY
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Ground (-) 24 Vdc (+)
®
OmniControl Surge Suppressor
P/N Q410 Patent Pending
123456
7 8 9 10 11 12 13
Removable Terminal Connectors
+ Radio Receiver
G
B
M/S Link
A
Center Loop
Safety Loop
Exit Loop
Fire Dept. Key Switch
Strike Open Push Button
Class 2 Supply
24 Volts DC
CLOSE
STEP 11
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
Output Power
STOP
EXIT
SENSOR ALARM
MADE IN USA
3 Wire 24 Vdc Radio Receiver
Master/Second Link: Not used in normal installation
13 + Radio Power Relay 12 11 24 Volt
Wire
4 Wire 24 Vdc Radio Receiver
WARNING: To ENSURE proper operation
of safety devices: · ENSURE bare wire makes good contact inside removable terminal connectors. · DO NOT let wire insulation interfere with connection.
13 + Red 24 Volt Grey 12 11 Black 11 Grey
3 4
10
Card Reader
External "Safety" Loop Detector
9
®
®
11 Ground (-) 13 24VDC (+)
®
10 9
Push Button
+24V SENSING EDGE INPUT INFRARED BLACK or BROWN COMMON INFRARED WHITE or BLUE
3 4
Photo Electric Sensors (Safety)
5 6
10 9
Phone Entry
1 4 7
HELP
2 5 8 0
3 6 9
External "Exit" Loop Detector
8 7
Fire or Any Key Switch
13
IMPORTANT INFORMATION
STEP 12
MER 60
CENTER SAFETY EXIT
1
3
OFF
ON
OPEN RIGHT
OPEN LEFT
DC-BACKUP SENSOR ALARM
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
RADIO
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
CLOSE
STOP
Make sure the system is "OPEN TO LEFT"
STEP 13
Installers are required to adhere to this procedure: The UL required Warning Signs must be installed in plain view and on both sides of each commercial gate installed. Each sign is made with fastening holes in each corner and should be permanently secured in a suitable manner.
14
INSTRUCTIONS FOR OPTIONAL SYSTEMS
CENTER
SAFETY
EXIT
QCC
AB
OPEN
SENSOR ALARM
STOP
CLOSE
MAGLOCK
ALARM
ARMED
M / S LIN K
DC-BACKUP
QCC
W4 GBA
OPEN A B MAGLOCK ALARM ARMED M/S LINK
MS LINK STOP CLOSE
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN STOP
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
CLOSE
1
N. O.
2
Gnd
3
N. C.
4
Gnd
5
N. O.
6
Gnd
7
Com
8
N. C.
9 10 11 12 13 14 15 16
N. O. Gnd Gnd B
POWER OVERLOAD OPEN CLOSE STOP
SENSOR ALARM
MADE IN USA
QCC is designed for slide gate operators only!
1 3 5
& & &
2 4 6 7 8 9
Open Command Stop Command 10 & 11 Close Command 12 & 13 Common 14 Relay Contact Rating Normally Closed 0. 5 Amp - 125 Vac 15 1 Amp - 24 Vdc Normally Open 16
Omni Option Board see Accessories page
Burglar Alarm Output Burglar Alarm Input Ground Master/Second B RS485 A
3-BUTTON STATION
Omni "Option Board" Needed to Perform This Function
WARNING: For proper operation, cut
OPEN STOP CLOSE
W4 BEFORE installing option board.
CENTER SAFETY EXIT
1 N. O. [. . . ] Failure to adjust and retest the operator properly may cause SERIOUS INJURY or DEATH. 5) Use the emergency release ONLY when the gate or door is not moving. (For door installations) If possible, use manual release ONLY when the door is closed. Weak or broken springs may cause the door to fall rapidly causing SERIOUS INJURY or DEATH. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN HCT 501130
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN HCT 501130 will begin.