User manual CHAMBERLAIN HCT 501130

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN HCT 501130. We hope that this CHAMBERLAIN HCT 501130 user guide will be useful to you.


CHAMBERLAIN HCT 501130 : Download the complete user guide (6407 Ko)

Manual abstract: user guide CHAMBERLAIN HCT 501130

Detailed instructions for use are in the User's Guide.

[. . . ] TABLE OF CONTENTS Features and Specifications Role of Specifiers and Designers Role of Dealers, Installers and Trained System Technicians UL Gate Classifications Role of End Users Overhead Gate / Door Systems Safety Installation Instructions Steps 1-2 Installation of Operator Steps 3-5 Mounting the Operator Step 6 How to Connect Power (120 Vac) Earth Ground Rod Step 7 Mounting and Wiring of the Reset Switch Step 8 Adjusting the Traveling Distance (Limit Switches) Step 9 Two Way Adjustable Reversing Sensor Step 10 Adjustable Timer Step 11 Terminal Input Connections Steps 12-13 IMPORTANT INFORMATION Operating Instructions for Optional Systems Three Push Button System House Alarm / Proximity Switch Connections Optional Relay Adapter Connection Secondary Entrapment Protection (Contact Sensor) Secondary Entrapment Protection (Non-Contact Sensor) Optional Plug-In Loop Detectors Wiring External Loop Detectors Programming the Radio Receiver Replacing the Control Board Audio Alarm Important Safety Instructions MANUAL RELEASE Troubleshooting Table Troubleshooting / LED Information Parts Illustrations Parts List Maintenance Accessories Operator Notes 2 3 3 4 5 5 6 7 8 9 10 11 12 12 13 14 15 15 16 17 18 19 20 21 22-23 24 24 25 26 27 28 29 30 30 31 32 MAINTENANCE & OPERATION INSTA LLA TIO N Important: DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician. For Toll Free Technical Support: 1-800-528-2806 www. liftmaster. com 1 FEATURES AND SPECIFICATIONS 141" 8. 25" 22. 01" VARIABLE OPERATING LENGTHS Door Height Operator Length 8 ft. Door 189 in. 4" 18. 875" 8. 36" CONTINUOUS CYCLE 240 LBS. PULL COMMERCIAL DOOR AND GATE OPERATOR 1/2 HP ­ 120 VAC 1PH ­ 60HZ ­ 4. 8 AMPS WEIGHT 123 LBS MOTOR - 120VAC 4. 8 Amp 1/2 HP instant reversing parking gate Leeson Motor GEAR BOX - 40 to 1 ratio, lubrication by oil bath gives smooth, quiet operation and features positive gate locking. NOISE ISOLATOR - Heavy duty rubber attachments isolate vibration, absorb shock and eliminate noise. [. . . ] The location of the power disconnect should be visible and clearly labeled. · ALL power and control wiring must be run in separate conduit. · BEFORE installing power wiring or control stations, be sure to follow ALL specifications and warnings described below. Failure to do so may result in SEVERE INJURY to persons and/or damage to operator. · Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate/door. Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from which to dissipate its energy safely into the earth. Without this path, the intense energy generated by lightning could be directed towards the operator. Although nothing can absorb the tremendous power of a direct lightning strike, proper grounding can protect the operator in most cases. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length. In certain circumstances, metal water pipes may be allowed for grounding the operator. Check and follow all local codes for proper grounding procedures. CAUTION: To avoid damaging gas, power, or other underground utility lines, contact local underground utility locating companies before digging. Minimum 12 Gauge Ground Wire connected to HCT Earth Ground Wire Black = 120 Vac Wire White = Neutral Wire Green = Earth Ground Wire Use UL Listed conduit to enclose power wires Chamberlain Professional Products is not responsible for improper installation or failure to comply with all necessary local building codes. 9 MOUNTING AND WIRING OF RESET SWITCH STEP 7 The reset switch allows the operator to be reset upon the event of a double entrapment alarm. When such an event occurs the alarm will continuously sound and the operator will not have any functionality until the board is reset. Mount reset switch at a minimum of 6' away from the gate/door jambs (Figure 1). Plug the interface cable (Figure 2) into the J5 receptacle on the Omni control board (Figure 3). NOTE: The wire connecting the interface cable to the reset switch is not provided. WARNING To prevent possible SERIOUS INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing. ALL electrical connections MUST be made by a qualified individual. Figure 1 RESET 6' min. RESET Figure 2 CENTER SAFETY EXIT Figure 3 DC-BACKUP QCC SENSOR ALARM Plug Reset Switch Connector to J5 Connector J5 DC-BACKUP W4 GBA OPEN A B MAGLOCK ALARM ARMED M / S L I NK MS STOP LINK CLOSE SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN CLOSE STOP REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR 10 ADJUSTING TRAVELING DISTANCE STEP 8 Before Adjusting, Do the Following: 1. If further adjustment is needed, repeat the process. Push Plate 11 2-WAY ADJUSTABLE REVERSING SENSOR STEP 9 Adjusted by Qualified Service Personnel CENTER SAFETY EXIT 3 1 3 DC-BACKUP W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT SENSOR ALARM REVERSE SENSOR Maximum Sensitivity MADE IN USA 1 3 1 3 COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR DO NOT TOUCH ALARM SENSOR The level of reverse sensitivity has to do with the weight of the gate/door and the condition of installation. Not sensitive enough = If the gate/door hits an obstruction or vehicle and does not stop or reverse. ADJUSTABLE TIMER STEP 10 TIMER CENTER SAFETY EXIT CLOSE Minimum Sensitivity EXIT STOP Timer ON 60 3 Set Timer Decrease Time NSOR OFF OPEN LEFT ON 1 3 OPEN RIGHT DC-BACKUP SENSOR ALARM W4 GBA MS LINK Increase Time TIMER NSOR SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 60 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED CLOSE STOP EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR OFF OPEN LEFT 1 3 ON OPEN RIGHT Timer can be set from 1 to 60 seconds (Timer ON), For push open/push close type operation (Timer OFF). Timer OFF 12 DC-BACKUP TERMINAL INPUT CONNECTIONS GBA MS LINK W4 SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN REVERSE SENSOR Important: Terminals 11 and 12 are the only terminals that will both Open and/or Close with OFF ON a single push of a button. All other terminals will only open with a single push of a button. ALARM SENSOR 1 3 1 3 1 3 OPEN LEFT OPEN RIGHT COMMAND PROCESSED CENTER SAFETY EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Ground (-) 24 Vdc (+) ® OmniControl Surge Suppressor P/N Q410 Patent Pending 123456 7 8 9 10 11 12 13 Removable Terminal Connectors ­ + Radio Receiver G B M/S Link A Center Loop Safety Loop Exit Loop Fire Dept. Key Switch Strike Open Push Button Class 2 Supply 24 Volts DC CLOSE STEP 11 FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED Output Power STOP EXIT SENSOR ALARM MADE IN USA 3 Wire 24 Vdc Radio Receiver Master/Second Link: Not used in normal installation 13 + Radio Power Relay 12 11 ­ 24 Volt Wire 4 Wire 24 Vdc Radio Receiver WARNING: To ENSURE proper operation of safety devices: · ENSURE bare wire makes good contact inside removable terminal connectors. · DO NOT let wire insulation interfere with connection. 13 + Red 24 Volt Grey 12 11 ­ Black 11 ­ Grey 3 4 10 Card Reader External "Safety" Loop Detector 9 ® ® 11 Ground (-) 13 24VDC (+) ® 10 9 Push Button +24V SENSING EDGE INPUT INFRARED BLACK or BROWN COMMON INFRARED WHITE or BLUE 3 4 Photo Electric Sensors (Safety) 5 6 10 9 Phone Entry 1 4 7 HELP 2 5 8 0 3 6 9 External "Exit" Loop Detector 8 7 Fire or Any Key Switch 13 IMPORTANT INFORMATION STEP 12 MER 60 CENTER SAFETY EXIT 1 3 OFF ON OPEN RIGHT OPEN LEFT DC-BACKUP SENSOR ALARM W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN RADIO REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP Make sure the system is "OPEN TO LEFT" STEP 13 Installers are required to adhere to this procedure: The UL required Warning Signs must be installed in plain view and on both sides of each commercial gate installed. Each sign is made with fastening holes in each corner and should be permanently secured in a suitable manner. 14 INSTRUCTIONS FOR OPTIONAL SYSTEMS CENTER SAFETY EXIT QCC AB OPEN SENSOR ALARM STOP CLOSE MAGLOCK ALARM ARMED M / S LIN K DC-BACKUP QCC W4 GBA OPEN A B MAGLOCK ALARM ARMED M/S LINK MS LINK STOP CLOSE SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN STOP REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED CLOSE 1 N. O. 2 Gnd 3 N. C. 4 Gnd 5 N. O. 6 Gnd 7 Com 8 N. C. 9 10 11 12 13 14 15 16 N. O. Gnd Gnd B POWER OVERLOAD OPEN CLOSE STOP SENSOR ALARM MADE IN USA QCC is designed for slide gate operators only! 1 3 5 & & & 2 4 6 7 8 9 ­ ­ ­ ­ ­ ­ Open Command Stop Command 10 & 11 Close Command 12 & 13 Common 14 Relay Contact Rating Normally Closed 0. 5 Amp - 125 Vac 15 1 Amp - 24 Vdc Normally Open 16 Omni Option Board see Accessories page ­ ­ ­ ­ ­ Burglar Alarm Output Burglar Alarm Input Ground Master/Second B RS485 A 3-BUTTON STATION Omni "Option Board" Needed to Perform This Function WARNING: For proper operation, cut OPEN STOP CLOSE W4 BEFORE installing option board. CENTER SAFETY EXIT 1 N. O. [. . . ] Failure to adjust and retest the operator properly may cause SERIOUS INJURY or DEATH. 5) Use the emergency release ONLY when the gate or door is not moving. (For door installations) If possible, use manual release ONLY when the door is closed. Weak or broken springs may cause the door to fall rapidly causing SERIOUS INJURY or DEATH. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN HCT 501130




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN HCT 501130 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.