Detailed instructions for use are in the User's Guide.
[. . . ] GL
CO NT RO LL ER
BO AR D
MODEL HS670
HEAVY DUTY HYDRAULIC SLIDE GATE OPERATOR
2 YEAR WARRANTY
Serial # ________________________ (located on electrical box cover) Installation Date __________________ MODEL HS670 IS FOR VEHICULAR PASSAGE GATES ONLY AND IS NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE
TABLE OF CONTENTS
OPERATOR SPECIFICATIONS
Carton Inventory . . 5
IMPORTANT NOTE
· BEFORE attempting to install, operate or maintain the operator, you MUST read and fully understand this manual and follow all safety instructions. · DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician.
OPERATOR WARNINGS
Safety Installation Information . . 8
CARTON INVENTORY
Before beginning your installation check that all components were provided and received undamaged. [. . . ] Repeat Steps 2 and 3 in the Programming Section below to reprogram the receiver for each remote control transmitter in use. SET OUTPUT DURATION
WARNING
To prevent possible SERIOUS INJURY or DEATH from electrocution: · Be sure power is not connected BEFORE installing the receiver. To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door: · ALWAYS keep remote controls out of reach of children. NEVER permit children to operate, or play with remote control transmitters. · Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel. · ALWAYS keep gate or garage door in sight until completely closed. NEVER permit anyone to cross path of moving gate or door.
CAUTION
FIGURE 1
Security Mode Terminals Jumper
WARNING
To prevent possible SERIOUS INJURY or DEATH, the use of CONSTANT OPERATION on residential openers is PROHIBITED.
CAUTION
AVERTISSEMENT WARNING ATTENTION WARNING
Security Mode Terminals Jumper NORMAL SECURITY MODE
For commercial applications, the receiver can be set for either constant or momentary closure on the output contacts. Use of constant closure is prohibited on residential garage door openers because it overrides the safety reversal devices. With the jumper in the "M" (Momentary) position, the contacts will close for 1/4 second regardless of the length of radio transmission. With the jumper in "C" (Constant) position, the contacts will stay closed as long as the radio continues transmitting (Figure 2). Pry open the front panel of receiver case with a coin or a screwdriver. Within 30 seconds, press and hold the button on the hand-held remote that you wish to operate your gate operator. The opener will now operate when the push button on either the receiver or the remote control is pressed. Repeat Steps 2 and 3 for each remote control that will be used to operate the gate operator.
HIGH SECURITY MODE
FIGURE 2
CONSTANT OPERATION Jumper MOMENTARY OPERATION Jumper
Output Duration Terminals
Output Duration Terminals
AVERTISSEMENT ATTENTION
AVERTISSEMENT ADVERTENCIA AVERTISSEMENT
FIGURE 3
OPENING RECEIVER OPEN RECEIVER Connect Antenna Indicator Light Learn Button
M M
C
P2
PRECAUCIÓN
TO ERASE ALL REMOTE CONTROL CODES Press and hold the "learn" button on the receiver panel until the indicator light turns off (about 6 seconds). Then follow the steps above to reprogram each remote control.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
M
Output Duration Terminals Security Mode Power Supply Jumper
24V
12V
ADVERTENCIA
19
NORM
HIGH
ADVERTENCIA
OPTIONAL CONTROL DEVICES
SEQUENCED ACCESS MANAGEMENT SYSTEM (SAMS)
SAMS DEFINITION The Sequenced Access Management System or SAMS allows the customer more control when managing vehicular entrances to areas such as industrial complexes, businesses and airports. The basic concept of the system is that traffic is controlled by two gates installed in tandem, a fast moving gate such as a barrier gate operator and a slower moving more secure or ornamental gate such as a single or pair of slide/swing gate operator. The design of this gate system balances the demands of speed during high traffic periods with security during low traffic periods. Barrier gates typically have the fastest open times of the many gate operator types and the slide or swing gates allow you to effectively seal off the perimeter of the complex you are planning to secure. If using a device, such as a 7-day timer, to latch the slide or swing gate open during high traffic times, connect the device's N/O relay output to the GL board's Interrupt Loop input. Once the device activates the Interrupt Loop input, the next vehicle to access the SAM system will lock the gate in the open position until the device deactivates. When the device deactivates, the timer to close will automatically close the gate. [. . . ] For single button radio function, perform the optional wire change.
31
ELECTRICAL BOX
COMPLETE ELECTRICAL BOX REPLACEMENT KITS To order a complete electrical box replacement kit, add a Kprefix to the model number of your operator. For example: HS670-100-21 (Operator) = K-HS670-100-21 (Electrical Box Kit)
3
5
7
8
10 2 15
13
6
12 14 9 1 9 4 11
INDIVIDUAL PARTS AND KITS
ITEM PART # 1 K001A5566 2 03-8024-K 3 10-19198 4 10-19199 5 21-3260-1 6 31-13703 7 35-310-032 8 G71-416-7NH 9 42-114-2 10 42-19200 11 42-8116-1 12 74-19201 13 23-3001 23-3005 14 31-G055 15 25-2015 25-2006 DESCRIPTION Control Board Contactor, 3 Pole Reversing Control Box Cover Mounting Bracket Transformer, 50/60HO, 60VA Standoffs for Optional Loop Detector Fuse, Glass Body 3. 2AMP 3AG Loop Detector Terminal Strip, 14 Poles Radio Block 4 Pole Terminal Strip, PCB 16 Pole Control Box Switch 1n Switch 3n Standoffs for GL Board Overload, 15AMP (230V 1PH) Overload, 6AMP (115V 1PH) QTY 1 1 1 1 1 8 1 2 1 1 1 1 1 3 1 NOTES PROVIDED IN KIT Individual Part Individual Part Individual Part Individual Part Individual Part Individual Part Optional Individual Part Individual Part Individual Part Individual Part Complete Assembly Individual Part Individual Part
Optional
1PH Units 3PH Units
NOTE: Single phase units are equipped with either an external line break device or an internal pilot-duty thermal O/L device.
32
I L L U S T R AT E D PA R T S
9
13
3 5
7 16
4
6
3 2 12 10 14 17
3 10
15 11
1 8
INDIVIDUAL PARTS AND KITS
ITEM 1 PART # K20-1100 K20-3100C-4 K20-3200C-4 K32-19007 K32-19008 K75-19103 K75-19102 K75-19101 K75-19100 K75-19099 K75-19098 K75-19097 K75-19096 K75-19095 K75-19094 29-19202 MG49130 K75-19090 K74-G0589 29-19203 80-19011 K75-19104 DESCRIPTION Motor, 1HP 115/230V 1PH Motor, 1HP 230/460V 3PH Motor, 2HP 230/460V 3PH Hydraulic Pump, Class 3&4 Hydraulic Pump, Class 1&2 Tension Rod, 1HP Tension Rod, 2HP Arm, Lower Pivot Arm, Upper Pivot Motor, Hydraulic Guide Assembly Base Assembly Drive Wheel, 1HP Drive Wheel, 2HP Limit Switch Directional Valve Arm Bushings Kit Operator Cover RPM Sensor (Hall Effect) Rectifier (for D. V. ) Traction Ring, H. E. Wheel RPM Assembly QTY 1 NOTES 1HP 1PH Units 1HP 3PH Units 2HP 3PH Units 18 I. P. S. 1HP Units 2HP Units PROVIDED IN KIT Individual Part
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1 1 1 1 2 1 1 2 1 1 1 1 1 1 1 1
Individual Part Tension Rod, Tension Spring and Mounting Hardware Pivot Arm and Mounting Hardware Pivot Arm and Mounting Hardware Individual Part Guide and Mounting Hardware Base, Mounting Legs and Shield Drive Wheel and Mounting Hardware Limit Switch and Limit Arm Individual Part Mounting Hardware Cover, Handle and Labels Hall Effect Board, Cable and Mounting Hardware Individual Part Individual Part Complete Assembly
1HP Units 2HP Units (2 Required)
33
WARRANTY POLICY
LIFTMASTER ® TWO YEAR LIMITED WARRANTY
The Chamberlain Group, Inc. [. . . ]