[. . . ] LA412 & LA412-S
12 VOLT DC SINGLE SOLAR RESIDENTIAL GATE OPERATOR
OW N E R ' S M A N U A L
FOR RESIDENTIAL USE ONLY
Please read this manual and the enclosed safety materials carefully!Periodic checks of the operator by a qualified technician are required to ensure safe operation. Serial # Installation date
2 YEAR WARRANTY
SAFETY
TABLE OF CONTENTS
Safety Symbol and Signal Word Review Safety Installation Information Gate Construction Information Important Safety Information
1-5 SOLAR PANEL INSTALLATION
1 2 3 4-5
25-28 29-32
29-31 32 32
ADJUSTMENT
Limits Force Adjustment Timer-to-Close
INTRODUCTION
Operator Specifications Carton Inventory Hardware Inventory Additional Items for Purchase Tools Needed
6-7
6 6 7 7 7
PROGRAMMING
Remote Controls Keyless Entry Erase All Codes Test
33
33 33 33 33
INSTALLATION
Overview of Typical Installation Check Your Gate Mounting Options Manual Release Determine the Position of the Pull-to-Open Bracket Determine the Position of the "Optional" Push-to-Open Bracket Assemble Gate Post Bracket (Pull-to-Open) Attach Brackets to Gate Operator Determine Mounting Location Measuring and Marking for the Gate Bracket Position Gate Operator on Gate Test Gate Travel Secure Post Bracket to Gate Post Secure Gate Bracket to Gate Warning Sign Placement Standard Control Box Large Metal Control Box (XLM)
8-19
8-9 10 10 11 11 11 12 12 13 13 14 15 15 16 16 17-18 19
OPERATION AND MAINTENANCE
Reset Button Remote Control Sleep Mode Manual Release Maintenance
34-35
34 34 34 35 35
TROUBLESHOOTING
Wiring Diagram Diagnostic Chart Troubleshooting Chart
36-39
36 37 38-39
REPAIR PARTS
WIRING
Connect the Gate Operator (Gate 1) to the Control Box 20 Set the Lock/Bipart Delay (Model LA412-S Only) 21 Connect the Gate Operator (Gate 2) to the Control Box (Model LA412-S Only) 22 Junction Box (Model LA412-S Only) 23-24
20-24
Control Box Gate Operator Arm How to Order Repair Parts
40-41
40 40 41
WARRANTY POLICY ACCESSORIES TEMPLATE
41 42 BACK COVER
SAFETY » SAFETY SYMBOL AND SIGNAL WORD REVIEW
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. [. . . ] NOTE: The system is designed to be charged by either an AC plug-in transformer or a separate solar panel, but not both. Use the cable ties to secure the solar panel cable away from places where it could be damaged.
Solar Panel
6
NOTE: If the sky is too overcast to allow the solar panel to power up the system, the panel will need to be verified at another time when the sun is shining. There is no other way to verify the panel installation.
P1
C1Ø1
R182
J19 J18
D36
SOL GND MAGR
K5 L1
U4 F12 D42 Z1 R2
LOCK
ON
LEARN XMITTER
OFF
C75
LOCK / BIPART DELAY
C7Ø C71 C72 C73
CONNECT BATTERIES
GATE 1
R1 D1Ø
BR
K2
GR WH YL BL RD
F8
The batteries are charged in circuit by using the solar panel (provided).
18
GATE 1
1 2 Connect the plug from the battery to connector on the control board.
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
K1
Z12
Locate the two white battery plugs on the left-hand side of the control box.
Battery Connectors
Control Board
Q9
GATE 2
TIMER RUNNING
24V
R1ØØ
R9Ø
J2Ø
BR GR WH
R1Ø1
S
K4
R186
1
3A 3ØA 32V
YL BL
D8 K3 D44
OFF
MAX
C12
OFF
MAX
RD
GATE 2
Q22 D16
F7 Z4 D2 C13 D129
U3
D4
R9
F9
R196
F2
C69
NOTES: Batteries will degrade over time depending on temperature and usage. Batteries do not perform well in extremely cold temperatures.
R42Ø R423 JU1 C11
MOV1
D1 R329 R27
J24
F1 J21
F3
AC PW /SOLA
K6
J23
30
30
C64
3ØA
3ØA 32V
U2 R22 32V
JU2 DB1 JU1
2
Board Connectors Battery Connection
28
ADJUSTMENT » LIMITS
LIMITS
The limits are internal settings that indicate when the gates are in the fully open position and the fully closed position. For proper functionality, the limits must be programmed during the installation process. The specific buttons used for programming depends on which side of the gate the control box is mounted and how many operators the installation includes. Refer to pages 10 and 11 to determine if the gate is Left- or Right-handed. If a mistake is made during programming press the RESET button on the outside of the control box to start over. The programming times-out automatically after 60 seconds of inactivity.
1 Close the gate. 2 Engage the operator by turning the release lever clockwise 180°, then turning the key clockwise 180°.
SINGLE ARM LEFT-HAND SIDE
OR
PROGRAM OPEN
SINGLE ARM RIGHT-HAND SIDE
PROGRAM OPEN
3
Press the LEARN LIMITS button (SET OPEN LIMIT LED will blink).
LEARN LIMITS button
3
Press the LEARN LIMITS button (SET OPEN LIMIT LED will blink).
LEARN LIMITS button
R2 R1 F3
R2
K2
K2
U4
SET OPEN LIMIT
SET EN OPEN T LIMIT
Z3 Z4
OFF
D9
U3
D4
D4 D1
D2
D2 D6
RESET BUTTON
RESET BUTTON
the Gate 4 Press button to 1 right move gate to the desired OPEN position.
DIAGNOSTIC
GATE 1
4
Press the Gate 1 left button to move gate to the desired OPEN position.
DIAGNOSTIC
GATE 1
SET CLOSE
SET CLOSE
LIMITS 5 the LEARNbeep. Control board will When gate is in the desired position, press
SET OPEN LIMIT
SET CLOSE LIMIT
is in press 5 When gatebeep. the desired position, Control the LEARN LIMITS button again. board will
SET OPEN LIMIT
SET CLOSE LIMIT
PROGRAM CLOSE
6 Press the Gate 1 left button to
PROGRAM CLOSE
DIAGNOSTIC
move gate to the desired CLOSED position.
6
When the SET CLOSE LIMIT LED blinks, press the Gate 1 right button.
DIAGNOSTIC
GATE 1
GATE 1
SET CLOSE
SET CLOSE
gate is in desired closed position, 7 Whenthe LEARNtheLIMITS button again. press
SET OPEN LIMIT
SET CLOSE LIMIT
gate is in desired closed 7 Whenthe LEARNtheLIMITS button. position, press
SET OPEN LIMIT
SET CLOSE LIMIT
The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is now complete. If the problem continues, see Troubleshooting section. ) Test the limits by pressing the SBC to open and close the gate. 29
ADJUSTMENT » LIMITS
LIMITS
NOTES: · The gate with the longer travel span (opening) must be set as the primary gate (GATE 1). · If one gate is overlapping the other, the gate that is overlapping must be connected to GATE 1 so it will start moving before the other gate; GATE 2 may need to be closed first if there is overlap or a gate lock is being used. · The programming can be exited at any time by pressing the RESET button. Programming times-out automatically after 60 seconds of inactivity.
DUAL GATE (LEFT-SIDE PRIMARY OPERATOR)
1 Close the gate. 2 Engage the operator by turning the release lever clockwise 180°, then turning the key clockwise 180°.
PROGRAM OPEN
the LEARN 3 Presswill blink). LIMITS button (SET OPEN LIMIT LED
LEARN LIMITS button
R2
K2
U4
SET OPEN LIMIT
D4
D2
RESET BUTTON
1 4 Press the GATEopen right button to the left operator.
DIAGNOSTIC
GATE 1
5
SET CLOSE
Press the GATE 2 right button to move the right operator into the OPEN position.
SET CLOSE LIMIT
LE LIMIT
GATE 2
6
Press the LEARN LIMITS button. Control board will beep.
SET OPEN LIMIT
SET CLOSE LIMIT
FORCE
PROGRAM CLOSE
7
When the SET CLOSE LIMITS LED blinks, press the GATE 2 left button to close the right operator.
SET CLOSE LIMIT
LE LIMITS
GATE 2
FORCE
8 GATE 1to left button
Press the
DIAGNOSTIC
GATE 1
9 Press the LEARN LIMITS button.
SET OPEN LIMIT SET CLOSE LIMIT
close the left operator.
SET CLOSE
The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is now complete. [. . . ] warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of TWO years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety. If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806, toll free, before dismantling this product. [. . . ]