User manual CHAMBERLAIN R900

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN R900. We hope that this CHAMBERLAIN R900 user guide will be useful to you.


CHAMBERLAIN R900 : Download the complete user guide (6219 Ko)

Manual abstract: user guide CHAMBERLAIN R900

Detailed instructions for use are in the User's Guide.

[. . . ] copyright © 2008 chamberlain professional products - www. Liftmaster. com TABLE OF CONTENTS 2 2 3 3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 19 19 20 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35-36 37 38 39 40-41 41 42 43 Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users / Home Owners Swing Gate Systems Warnings and Precautions Safely Operating Gate Configuration and Specifications Concrete Pad and Gate Attachment Standard Installation Compact Installation Gate Arm Installation Gate Movement Direction Adjustment of Output Shaft Earth Ground Rod DC Power Supply Connection "Optional" Solar Panel Surge Suppressor Terminal Input Connections Adjusting Gate Traveling Distance Timer Adjustment Reversing Sensor Warning Placard Placement Emergency Release Safety Device Wiring "Optional" Input Board Maglock Wiring Connection Optional 12 VDC Photo Beam Wiring 3-Push Button Wiring Connection 3-Push Button Wiring Master / Second Single Operator Loop Size and Placement Master / Second Loop Size and Placement Loop Installation and Number of Wire Turns Wiring Loop Detector to Operator Master and Second Operators with Timer Master and Second Operators without Timer Control Board Functions Control Board LED Descriptions Troubleshooting How to Reset Breaker Switch / How to Check Fuses Gate will not close!If you hear a "BEEP" sound (Audio Alarm) Robo Swing Parts Illustrations, Robo Swing Parts List Maintenance Elite Robo Swing Accessories Owners Checklist of Installation 1 ROLE OF SPECIFIERS AND DESIGNERS Specifiers and designers should design an automatic vehicular gate system to: · Utilize an operator suited for gate system type, size, frequency of use, location and user population. · Reduce risk of entrapment injuries by minimizing all gaps in the gate and enclosing the area of the travel of the gate. · Consider special populations, such as children or the elderly. [. . . ] The only recommended external devices other than radio receivers are dry-contact command devices which do not consume any current like key switches. Using other devices that consume high current such as telephone access, magnetic locks or loop detectors will cause excess drainage of the battery and eventually completely drain the battery. CAUTION Chamberlain Elite recommends using a larger battery (12 Vdc, 30 AHr) (Part # A 12330) in this operator when using the optional solar panel. 12 VDC r 30 AH For More Details, contact your Local Dealer 17 SURGE SUPPRESSOR TERMINAL CONNECTIONS The radio receiver must be 12 Vdc only (Part # A 1099-12V). If you want to use safety or exit loops, you must use 12 Vdc loop detectors only (Part # A 23). ® ® DC ­ DC ACCE SS SYSTE MS INC P/N Q412 ROBOSURGESUPPRESSOR PATENT PENDING PATENT 7 8 9 10 11 12 13 1­­456 ­ POWER INPUT 25VDC SAFETY LOOP EXIT LOOP FIREDEPT KEY SWITCH STRIKEOPEN PUSHBUTTON + RADIO RECEIVER CLASS 2 SUPPLY 4 Wire -12 Vdc Radio Receiver 1 Red 13 + 12 Volt To 120 Vac Polarity does NOT Matter 11 ­ Neg. 12 2 Black 3 White 4 Green ® Com. 11 ­ Neg. DC DC Plug-In Transformer 25 Vdc 1 4 External "Safety" Loop Detector 12 Vdc 10 9 Card Reader 10 9 Push Button 1 4 Photo Beam (Safety) 12 Vdc 10 9 Phone Entry 1 4 7 HELP 2 5 8 0 3 6 9 5 6 External "Exit" Loop Detector 12 Vdc 8 7 Fire or Any Key Switch 18 ADJUSTING GATE TRAVELING DISTANCE Release the red handle and open the gate to a distance desired. Turn limit cam until the half moon shape hits the limit switch and you hear the switch click. For a more precise adjustment, use the set allen screw. Limit Cams Adjust Limit Cams Limit Switches Allen Screw Loosen Screw ADJUSTABLE TIMER If you want to use the automatic close for the gate system the timer switch should be put in the "ON" position. If you want to use the push open or push close command, the timer should be switched to the "OFF" position. CHECK CHARGINGFUSE POWER BOARD POWER SYSTEM ON TIMER Set Timer 0 to 60 seconds UP PW STOP OVERLOAD POWER J2 ALARM SENSOR REVERSE SENSOR ON 60 OFF HEAVY GATE 0 CLOSE CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONT FIRE DEPT ROL OPEN STRIKE OPEN SAFETY LOOP EXIT LOOP RADIO REC ON 60 OFF 0 TIMER ON UP PW STOP OPEN TO RIGH T 60 0 CLOSE OFF 19 W1 CLOSE STOP TIMER UP PW ADJUSTABLE REVERSING SENSOR Adjust the "Reverse Sensor" pot on the upper portion of the control board. The level of reverse sensitivity depends on the weight of the gate and the condition of installation. Not sensitive enough = if the gate hits an object and does not stop or reverse. Do Not Touch Alarm Sensor Pot Minimum Sensitivity HEAVY GATE CHECK CHARGINGFUSE POWER BOARD POWER SYSTEM ON J2 Important Note! There is a "Heavy Gate" LED which will light up when the gate is heavier than normal. This is a diagnostic LED and the operator will still function normally when this indicator is on. SYSTEM ON ALARM SENSOR ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW REVERSE SENSOR OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONTRO FIRE DEPT STRIKE OPEN L STOP TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 OFF 0 CLOSE OPEN TO RIGHT Maximum Sensitivity WARNING PLACARD PLACEMENT Warning placards need to be permanently mounted on BOTH sides of the gate. 20 W1 OPEN EMERGENCY 1 Unscrew Bolt Special tool required for the "optional" security bolt RELEASE 2 Lift Off Cover 3 Loosen Red Handle Gate can now be manually moved Grab the Gate to Make Adjustments Tighten the Red Handle, Replace the Cover and Bolt when Finished When the power is turned on again, the gate will readjust itself automatically. 21 SAFETY DEVICE WIRING Sensing Edges ® ® DC ­ DC ACCE SS SYSTE MS INC P/N Q412 ROBOSURGESUPPRESSOR PATENT PENDING PATENT 7 8 9 10 11 12 13 1­­456 ­ POWER INPUT 25VDC SAFETY LOOP EXIT LOOP FIREDEPT KEY SWITCH STRIKEOPEN PUSHBUTTON + RADIO RECEIVER CLASS 2 SUPPLY Sensor Edges Top of Gate Sensor Edge Wires 1 4 Important: gate will stop and reopen upon activation of device Photo Beam Entrapment Protection Optional input board needed to preform this function P/N Q412 PATENT PENDING PATENT Part # A OMRON12V 7 8 9 10 11 12 13 16-Pin Plug 1 3 5 7 9 11 13 15 16 ­ FIREDEPT KEY SWITCH STRIKEOPEN PUSHBUTTON + RADIO RECEIVER 2 4 6 8 10 12 14 3&4 Black Orange CHECK CHARGINGFUSE POWER BOARD POWER ­+ Blue Brown SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD HEAVY GATE 11 13 POWER CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONTRO FIRE DEPT STRIKE OPEN L STOP TIMER UP PW SAFETY LOOP EXIT LOOP RADIO REC W1 OFF Cut W1 Jumper at Bottom of Board Wall OPEN TO RIGHT Danger Gate Open Mounted Reflector 22 W1 CLOSE Important: If photo beam is blocked the gate will stop. The gate will remain stopped until the beam is cleared. ON 60 0 OPEN "OPTIONAL" INPUT BOARD The optional board allows extra control of the gate, is available only from Chamberlain Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. 1&2 3&4 5&6 7&8 9 &10 d 11 & 4 12 & 7 13 & 14 15 & 16 Open Switch (N. O. ) Stop Switch (N. C. ) (Cut W1 Jumper at Bottom of Board) Timer Close Output to Slave Timer Input from Master (Close Command or Close Switch) (N. O. ) Alarm Output will be set off with very heavy gates or object preventing gate operation. (Not Burglar Alarm) (9 = +12 Vdc, 10 = Alarm) Emergency Open Switch (Direct Command from Battery to Motor) Emergency Close Switch (Direct Command from Battery to Motor) Magnetic Lock - Dry Contact Relay (13 = Com, 14 = N. C. ) Center Loop Option (For Swing Gate Operators Only) W1 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE POWER BOARD POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL 23 OPEN FIRE DEPT MAGLOCK WIRING CONNECTION The "Optional" input board MUST be used to perform this function. (Part# Q203) Custom Bracket Magnetic Lock Plate Magnetic Lock Gate Fence Part # A MG 1300 Relay Contact Rating 0. 5 Amp - 125 VAC 1 Amp - 24 VDC Dry Contact Relay 14 13 N. C. Common Power for Maglock 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE POWER BOARD POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA 24 CENTRAL CO N OPTIONAL 12 VDC PHOTO BEAM SAFETY WIRING ® ® DC ­ DC ACCE SS SYSTE MS INC P/N Q412 ROBOSURGESUPPRESSOR PATENT PENDING PATENT 7 8 9 10 11 12 13 1­­456 ­ ­ POWER INPUT 25VDC SAFETY LOOP EXIT LOOP FIREDEPT KEY SWITCH STRIKEOPEN PUSHBUTTON + + RADIO RECEIVER CLASS 2 SUPPLY Orange 1 (Part # A OMRON 12V) (Failsafe) 4 White Blue 11 Brown 13 Power Photo Beam (Safety) 12 Vdc It is best to use 12 Vdc Failsafe Photo Beam Sensors for this Safety Option Failsafe Photo Beam: If a failsafe photo beam is not working or loses power or photo beam is blocked, then the photo beam will stop all gate operation. Important: If photo beam is blocked the gate will stop and reopen. The gate will remain open until the obstruction is cleared. Contact your local dealer for more information. 25 3­PUSH BUTTON WIRING CONNECTION The "Optional" input board MUST be used to perform this function. (Part# Q203) There can be NO common wires within this 3-push button station. Open-N. O. Contact 2 4 8 N. C. 1 3 7 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE POWER BOARD POWER SYSTEM ON J2 ALARM SENSOR Cut W1 jumper at the bottom of Board to use the stop button in the 3-push button station REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA W1 CENTRAL CON TROL OPEN FIRE DEPT STRIKE OPEN STOP TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 OFF 0 CLOSE OPEN TO RIG HT 26 W1 3­PUSH BUTTON WIRING MASTER/SECOND The "Optional" input board MUST be used on both operators to perform this function (Part# Q203). [. . . ] If the board power or charging power LEDs are "ON", change the corresponding fuse on the top left corner of the board. CHECK FUSE CAUTION Replace fuse with 1. 5A - 250V fuse CHARGING POWER BOARD POWER J2 OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW Robo Fuse (Part # Q162) OPEN RELAY CLOSE RELAY DC OPE MAD 37 TROUBLESHOOTING The Gate Will Not Close! DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL FIRE DEPT STRIKE OPEN The radio receiver LED on the control board remains "ON" when using the remote control. STOP Symptom: PW SAFETY LOOP EXIT LOOP Possible Solutions: Stuck remote control button. The radio receiver has malfunctioned in the "ON" position. CLOSE 0 RADIO REC The Gate Will Not Open! DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL FIRE DEPT STRIKE OPEN Symptom: The radio receiver LED on the control board remains "OFF" when using the remote control. PW STOP SAFETY LOOP EXIT LOOP 0 CLOSE Possible Solutions: Dead battery in the remote control. Remote control code switches are different from radio receiver code switches. The radio receiver has malfunctioned in the "OFF" position. RADIO REC For further information, contact your local dealer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN R900




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN R900 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.