If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN ROBO SLIDE. We hope that this CHAMBERLAIN ROBO SLIDE user guide will be useful to you.
Manual abstract: user guide CHAMBERLAIN ROBO SLIDE
Detailed instructions for use are in the User's Guide.
[. . . ] ® ®
INSTRUCTION
MANUAL
THE ROBO SLIDE
RESIDENTIAL SLIDE GATE OPERATOR
Installation instructions and manual book for architects, general contractors and dealers
copyright © 2008 chamberlain professional products - www. liftmaster. com
TABLE OF CONTENTS
SPECIFICATIONS AND WARNINGS
Specifications and Warnings . 10 11 12 13 14 15 16 17 18 19 20 21 22 23
WARNING
Mechanical
WARNING
Electrical
CAUTION
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. 30
IMPORTANT NOTE
· BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. [. . . ] Do not use solar panel and plug-in transformer at the same time.
CAUTION
To AVOID damaging 25 Vdc plug-in transformer, it MUST be enclosed in a suitable weatherproof enclosure and provided with proper weatherproof fixtures. To AVOID damaging control board, DO NOT use the solar panel and the plug-in transformer at the same time.
® ®
DC DC
ACCESS SYSTEMS INC
Solar Panel
(SOLAR3) No Stand
POWER INPUT 25 VDC
® ®
DC DC
ACCESS SYSTEMS INC
P/N Q412 ROBO SURGE SUPPRESSOR PATENT PENDING PATENT 7 8 9 10 11 12 13 1456
+ RADIO RECEIVER
Polarity Does Not Matter
POWER INPUT 25 VDC
SAFETY LOOP
EXIT LOOP
FIRE DEPT KEY SWITCH
STRIKE OPEN PUSH BUTTON
CLASS 2 SUPPLY
Energizing this operator with solar power only needs the radio receiver to operate the gate. The only recommended external devices other than radio receivers are dry-contact command devices which do not consume any current like key switches. Using other devices that consume high current such as telephone access, magnetic locks or loop detectors will cause excess drainage of the battery and eventually completely drain the battery. For more details, contact your local dealer.
CAUTION
Chamberlain Elite recommends using a larger battery (12 VDC, 30 AHr) (Part # A12330SGLPK) in this operator when using the optional solar panel.
12 VDC r 30 AH
13
"OPTIONAL" FIRE RELEASE BOX
The "Fire Release Box", is designed for use on sliding gates. The doors can be locked with your own padlock, or the fire department's padlock. A steel cable with a T-handle runs from the box to the release mechanism at the rear end of the chain. The release mechanism, is placed where the chain bolt would normally be. To reset, simply reinsert the pin into the housing for normal operation (Part # ACP17).
Pull firmly on the "T" Handle to release the chain.
Contact your local dealer for more information.
The chain is held in place by a spring loaded pin.
14
"OPTIONAL" INPUT BOARD
The optional board allows extra control of the gate, is available only from Chamberlain Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. Below lists the function of each pin.
1 & 2 Open Switch (N. O. ) 3 & 4 Stop Switch (N. C. ) (Cut W1 Jumper at Bottom of Board) 5 & 6 Timer Close Output to Slave 7 & 8 Timer Input from Master (Close Command or Close Switch) (N. O. ) 9 &10 Alarm Output will be set off with very heavy gates or object preventing gate operation. d (Not Burglar Alarm) (9 = +12 VDC, 10 = Alarm) 11 & 4 Emergency Open Switch (Direct Command from Battery to Motor) 12 & 7 Emergency Close Switch (Direct Command from Battery to Motor) 13 & 14 Magnetic Lock - Dry Contact Relay (13 = Com, 14 = N. C. ) 15 & 16 Center Loop Option (For Swing Gate Operators Only)
W1
1 3 5 7 9 11 13 15
2 4 6 8 10 12 14 16
16-Pin Plug
CHECK
CHARGINGFUSE BOA RD POWER POWER
SYSTEM ON
J2
ALARM SENSOR
REVERSE SENSOR
OVERLOAD POWER
CHARGE OK
HEAVY GATE
BATTERY LOW OPEN RELAY CLOSE RELAY
DC OPERATOR v 5M MADE IN USA
CENTRAL CO
NTROL
15
OPEN
FIRE DEPT
SOLENOID/MAGLOCK CONNECTION
CAUTION
The "Optional" input board MUST be used to perform this function (Part# Q203). To ENSURE proper operation of external devices: · ENSURE bare wires make good contact inside removable terminal connections. · DO NOT let wire insulation interfere with connection.
Part # A MG 1300
Dry Contact Relay Relay Contact Rating 0. 5 Amp - 125 VAC 1 Amp - 24 VDC
14 13
N. C. Common
Power for Maglock
1 3 5 7 9 11 13 15
2 4 6 8 10 12 14 16
16-Pin Plug
CHECK
CHARGINGFUSE BOAR D POWER POWER
SYSTEM ON
J2
ALARM SENSOR
REVERSE SENSOR
OVERLOAD POWER
CHARGE OK
HEAVY GATE
BATTERY LOW OPEN RELAY CLOSE RELAY
DC OPERATOR v 5M MADE IN USA
CENTRAL CO
NTROL
16
"OPTIONAL" 12 VDC PHOTO BEAM WIRING
WARNING
To prevent SERIOUS INJURY or DEATH from a moving gate: · Locate entrapment protection devices to protect in BOTH the open and close gate cycles. · Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
® ®
DC DC
ACCESS SYSTEMS INC
P/N Q412 ROBO SURGE SUPPRESSOR T A PENT PENDING 7 8 9 10 11 12 13 1456
POWER INPUT 25 VDC SAFETY LOOP EXIT LOOP FIRE DEPT KEY SWITCH STRIKE OPEN PUSH BUTTON
+ + RADIO RECEIVER
CLASS 2 SUPPL Y
Orange
White
Blue
Brown
1
(Part # A OMRON 12V) (Failsafe)
4
Power
11 13
Photo Beam (Safety) 12 VDC
It is best to use 12 VDC Failsafe Photo Beam Sensors for this Safety Option Failsafe Photo Beam: If a failsafe photo beam is not working or loses power or photo beam is blocked, then the photo beam will stop all gate operation.
NOTE: If photo beam is blocked the gate will stop and reopen. The gate will remain open until the obstruction is cleared.
Contact your local dealer for more information.
17
OPTIONAL EDGE SENSOR WIRING
WARNING
To prevent SERIOUS INJURY or DEATH from a moving gate: · Locate entrapment protection devices to protect in BOTH the open and close gate cycles. · Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls. NOTE: When touched, these electrically activated edge sensors immediately signal the gate operator to stop and reverse. See page 37 for edge sensor part numbers.
® ®
DC DC
ACCESS SYSTEMS INC
P/N Q412 ROBO SURGE SUPPRESSOR PATENT PENDING 7 8 9 10 11 12 13 1456
POWER INPUT 25 VDC SAFETY LOOP EXIT LOOP FIRE DEPT KEY SWITCH STRIKE OPEN PUSH BUTTON
+ RADIO RECEIVER
CLASS 2 SUPPLY
· Never Paint Sensing Edge
1 4
· Never Pull On Wires · Never Cut or Puncture Edge · Never Operate Unguarded Equipment
Contact your local dealer for more information.
Miller Edge Models: MGR20 or MGS20
18
3-BUTTON CONTROL STATION WIRING CONNECTION
CAUTION
IMPORTANT NOTE: The "Optional" input board (Q203) must be used to perform this function. To ENSURE proper operation of external devices: · ENSURE bare wires make good contact inside removable terminal connections. · DO NOT let wire insulation interfere with connection.
There can be NO common wires within this 3-button control station.
Open-N. O. [. . . ] Bad Charging power fuse
3 Battery Low
normally off - it will indicate low battery
Battery OK Battery voltage is over minimum required limit
4 Heavy Gate
will work only when the gate is in motion
Gate weight and condition are OK
5 Open Relay 6 Close Relay 7 System On
Open relay is not energized Close relay is not energized 1. No motor current detected
will work only when the gate is in motion
8 Alarm Sensor
Detecting motor current
when LED goes on you will hear a "beep" sound for about 20 seconds LED will flash 3 times for "board OK" during power connection.
1. Unwanted object has physically stopped gate
System is OK
NOTE: Circled red numbers indicates location on control board, identified on page 10.
32
LED DESCRIPTION - CONTINUED
LED Description
9
LED On
Sensor is detecting obstruction
LED Off
No obstruction is detected
Reversing Sensor
10 Central Control
Acknowledgement of receiving open command from one of the surge suppressor terminals · Fire Department 7 & 8 · Strike Open 9 & 10 · Safety Loop 1 & 4 · Exit Loop 5&6 · Radio Receiver 11 & 12 Receiving signal at the surge suppressor terminal block 7&8 Receiving signal at the surge suppressor terminal block 9 & 10 Receiving signal at the surge suppressor terminal block 1&4 Receiving signal at the surge suppressor terminal block 5&6 Receiving signal at the surge suppressor terminal block 11 & 12
Not receiving any command
11 Fire Dept
Not receiving signal at the surge suppressor terminal block 7 & 8 Not receiving signal at the surge suppressor terminal block 9 & 10 Not receiving signal at the surge suppressor terminal block 1 & 4 Not receiving signal at the surge suppressor terminal block 5 & 6 Not receiving signal at the surge suppressor terminal block 11 & 12
12 Strike Open
13 Safety Loop
14 Exit Loop
15 Radio Rec
16 Timer PW
Timer power is on
Timer is not on
17 Timer UP
Output signal to close relay
Not receiving signal to close relay
NOTE: Circled red numbers indicates location on control board, identified on page 10.
33
HOW TO RESET THE BREAKER
If all electronic sensors fail or are not adjusted properly due to heavy gates, off-track gate, or obstructed gate path, the breaker . Reset the breaker by pressing the reset button located on the bottom left corner of the control board.
WARNING
To prevent SERIOUS INJURY or DEATH from a moving gate: ALWAYS disconnect the battery before resetting the breaker or injury could occur as the gate starts.
OPEN TO RI
GHT
The breaker reset is located at the bottom left corner of the control board as shown
HOW TO CHECK THE FUSES
If the gate is not moving in any direction be sure to check all of the LED displays on the control board. [. . . ]