User manual CHAMBERLAIN ROBO SLIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN ROBO SLIDE. We hope that this CHAMBERLAIN ROBO SLIDE user guide will be useful to you.


CHAMBERLAIN ROBO SLIDE : Download the complete user guide (6829 Ko)

Manual abstract: user guide CHAMBERLAIN ROBO SLIDE

Detailed instructions for use are in the User's Guide.

[. . . ] ® ® INSTRUCTION MANUAL THE ROBO SLIDE RESIDENTIAL SLIDE GATE OPERATOR Installation instructions and manual book for architects, general contractors and dealers copyright © 2008 chamberlain professional products - www. liftmaster. com TABLE OF CONTENTS SPECIFICATIONS AND WARNINGS Specifications and Warnings . 10 11 12 13 14 15 16 17 18 19 20 21 22 23 WARNING Mechanical WARNING Electrical CAUTION When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. 30 IMPORTANT NOTE · BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. [. . . ] Do not use solar panel and plug-in transformer at the same time. CAUTION To AVOID damaging 25 Vdc plug-in transformer, it MUST be enclosed in a suitable weatherproof enclosure and provided with proper weatherproof fixtures. To AVOID damaging control board, DO NOT use the solar panel and the plug-in transformer at the same time. ® ® DC ­ DC ACCESS SYSTEMS INC Solar Panel (SOLAR3) No Stand POWER INPUT 25 VDC ® ® DC ­ DC ACCESS SYSTEMS INC P/N Q412 ROBO SURGE SUPPRESSOR PATENT PENDING PATENT 7 8 9 10 11 12 13 1­­456 ­ + RADIO RECEIVER Polarity Does Not Matter POWER INPUT 25 VDC SAFETY LOOP EXIT LOOP FIRE DEPT KEY SWITCH STRIKE OPEN PUSH BUTTON CLASS 2 SUPPLY Energizing this operator with solar power only needs the radio receiver to operate the gate. The only recommended external devices other than radio receivers are dry-contact command devices which do not consume any current like key switches. Using other devices that consume high current such as telephone access, magnetic locks or loop detectors will cause excess drainage of the battery and eventually completely drain the battery. For more details, contact your local dealer. CAUTION Chamberlain Elite recommends using a larger battery (12 VDC, 30 AHr) (Part # A12330SGLPK) in this operator when using the optional solar panel. 12 VDC r 30 AH 13 "OPTIONAL" FIRE RELEASE BOX The "Fire Release Box", is designed for use on sliding gates. The doors can be locked with your own padlock, or the fire department's padlock. A steel cable with a T-handle runs from the box to the release mechanism at the rear end of the chain. The release mechanism, is placed where the chain bolt would normally be. To reset, simply reinsert the pin into the housing for normal operation (Part # ACP17). Pull firmly on the "T" Handle to release the chain. Contact your local dealer for more information. The chain is held in place by a spring loaded pin. 14 "OPTIONAL" INPUT BOARD The optional board allows extra control of the gate, is available only from Chamberlain Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. Below lists the function of each pin. 1 & 2 Open Switch (N. O. ) 3 & 4 Stop Switch (N. C. ) (Cut W1 Jumper at Bottom of Board) 5 & 6 Timer Close Output to Slave 7 & 8 Timer Input from Master (Close Command or Close Switch) (N. O. ) 9 &10 Alarm Output will be set off with very heavy gates or object preventing gate operation. d (Not Burglar Alarm) (9 = +12 VDC, 10 = Alarm) 11 & 4 Emergency Open Switch (Direct Command from Battery to Motor) 12 & 7 Emergency Close Switch (Direct Command from Battery to Motor) 13 & 14 Magnetic Lock - Dry Contact Relay (13 = Com, 14 = N. C. ) 15 & 16 Center Loop Option (For Swing Gate Operators Only) W1 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE BOA RD POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL 15 OPEN FIRE DEPT SOLENOID/MAGLOCK CONNECTION CAUTION The "Optional" input board MUST be used to perform this function (Part# Q203). To ENSURE proper operation of external devices: · ENSURE bare wires make good contact inside removable terminal connections. · DO NOT let wire insulation interfere with connection. Part # A MG 1300 Dry Contact Relay Relay Contact Rating 0. 5 Amp - 125 VAC 1 Amp - 24 VDC 14 13 N. C. Common Power for Maglock 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE BOAR D POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL 16 "OPTIONAL" 12 VDC PHOTO BEAM WIRING WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: · Locate entrapment protection devices to protect in BOTH the open and close gate cycles. · Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls. ® ® DC ­ DC ACCESS SYSTEMS INC P/N Q412 ROBO SURGE SUPPRESSOR T A PENT PENDING 7 8 9 10 11 12 13 1­­456 ­ ­ POWER INPUT 25 VDC SAFETY LOOP EXIT LOOP FIRE DEPT KEY SWITCH STRIKE OPEN PUSH BUTTON + + RADIO RECEIVER CLASS 2 SUPPL Y Orange White Blue Brown 1 (Part # A OMRON 12V) (Failsafe) 4 Power 11 13 Photo Beam (Safety) 12 VDC It is best to use 12 VDC Failsafe Photo Beam Sensors for this Safety Option Failsafe Photo Beam: If a failsafe photo beam is not working or loses power or photo beam is blocked, then the photo beam will stop all gate operation. NOTE: If photo beam is blocked the gate will stop and reopen. The gate will remain open until the obstruction is cleared. Contact your local dealer for more information. 17 OPTIONAL EDGE SENSOR WIRING WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: · Locate entrapment protection devices to protect in BOTH the open and close gate cycles. · Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls. NOTE: When touched, these electrically activated edge sensors immediately signal the gate operator to stop and reverse. See page 37 for edge sensor part numbers. ® ® DC ­ DC ACCESS SYSTEMS INC P/N Q412 ROBO SURGE SUPPRESSOR PATENT PENDING 7 8 9 10 11 12 13 1­­456 ­ POWER INPUT 25 VDC SAFETY LOOP EXIT LOOP FIRE DEPT KEY SWITCH STRIKE OPEN PUSH BUTTON + RADIO RECEIVER CLASS 2 SUPPLY · Never Paint Sensing Edge 1 4 · Never Pull On Wires · Never Cut or Puncture Edge · Never Operate Unguarded Equipment Contact your local dealer for more information. Miller Edge Models: MGR20 or MGS20 18 3-BUTTON CONTROL STATION WIRING CONNECTION CAUTION IMPORTANT NOTE: The "Optional" input board (Q203) must be used to perform this function. To ENSURE proper operation of external devices: · ENSURE bare wires make good contact inside removable terminal connections. · DO NOT let wire insulation interfere with connection. There can be NO common wires within this 3-button control station. Open-N. O. [. . . ] Bad Charging power fuse 3 Battery Low normally off - it will indicate low battery Battery OK Battery voltage is over minimum required limit 4 Heavy Gate will work only when the gate is in motion Gate weight and condition are OK 5 Open Relay 6 Close Relay 7 System On Open relay is not energized Close relay is not energized 1. No motor current detected will work only when the gate is in motion 8 Alarm Sensor Detecting motor current when LED goes on you will hear a "beep" sound for about 20 seconds LED will flash 3 times for "board OK" during power connection. 1. Unwanted object has physically stopped gate System is OK NOTE: Circled red numbers indicates location on control board, identified on page 10. 32 LED DESCRIPTION - CONTINUED LED Description 9 LED On Sensor is detecting obstruction LED Off No obstruction is detected Reversing Sensor 10 Central Control Acknowledgement of receiving open command from one of the surge suppressor terminals · Fire Department 7 & 8 · Strike Open 9 & 10 · Safety Loop 1 & 4 · Exit Loop 5&6 · Radio Receiver 11 & 12 Receiving signal at the surge suppressor terminal block 7&8 Receiving signal at the surge suppressor terminal block 9 & 10 Receiving signal at the surge suppressor terminal block 1&4 Receiving signal at the surge suppressor terminal block 5&6 Receiving signal at the surge suppressor terminal block 11 & 12 Not receiving any command 11 Fire Dept Not receiving signal at the surge suppressor terminal block 7 & 8 Not receiving signal at the surge suppressor terminal block 9 & 10 Not receiving signal at the surge suppressor terminal block 1 & 4 Not receiving signal at the surge suppressor terminal block 5 & 6 Not receiving signal at the surge suppressor terminal block 11 & 12 12 Strike Open 13 Safety Loop 14 Exit Loop 15 Radio Rec 16 Timer PW Timer power is on Timer is not on 17 Timer UP Output signal to close relay Not receiving signal to close relay NOTE: Circled red numbers indicates location on control board, identified on page 10. 33 HOW TO RESET THE BREAKER If all electronic sensors fail or are not adjusted properly due to heavy gates, off-track gate, or obstructed gate path, the breaker . Reset the breaker by pressing the reset button located on the bottom left corner of the control board. WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: ALWAYS disconnect the battery before resetting the breaker or injury could occur as the gate starts. OPEN TO RI GHT The breaker reset is located at the bottom left corner of the control board as shown HOW TO CHECK THE FUSES If the gate is not moving in any direction be sure to check all of the LED displays on the control board. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN ROBO SLIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN ROBO SLIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.