User manual CHAMBERLAIN SL585
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN SL585. We hope that this CHAMBERLAIN SL585 user guide will be useful to you.
Manual abstract: user guide CHAMBERLAIN SL585
Detailed instructions for use are in the User's Guide.
[. . . ] GL
CO NT RO LL ER
BO AR D
HEAVY DUTY SLIDE GATE OPERATOR
MODEL SL585
MODEL SL595
2 YEAR WARRANTY
Serial # ________________________ (located on electrical box cover) Installation Date__________________
HEAVY DUTY, HARSH ENVIRONMENT SLIDE GATE OPERATOR
MODELS SL585 AND SL595 ARE FOR VEHICULAR PASSAGE GATES ONLY AND ARE NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE
TABLE OF CONTENTS
OPERATOR SPECIFICATIONS
Carton Inventory . 4
IMPORTANT NOTES
· BEFORE attempting to install, operate or maintain the operator, you MUST read and fully understand this manual and follow all safety instructions. · DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician.
OPERATOR WARNINGS
Safety Installation Information . 12
CAUTION WARNING WARNING Electrical WARNING CAUTION
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of SERIOUS INJURY or DEATH if you do not comply with the warnings that accompany them. [. . . ] The opener will now operate when the push button on either the receiver or the remote control is pressed. Repeat Steps 2 and 3 for each remote control that will be used to operate the gate operator. TO ERASE ALL REMOTE CONTROL CODES Press and hold the "learn" button on the receiver panel until the indicator light turns off (about 6 seconds). Then follow the steps above to reprogram each remote control.
FIGURE 2
CONSTANT Jumper OPERATION Output Duration Terminals MOMENTARY Jumper OPERATION Output Duration Terminals
FIGURE 3
OPENING RECEIVER OPEN RECEIVER Connect Antenna Indicator Light Learn Button
M
C
P2
M
Output Duration Terminals Security Mode Power Supply Jumper
24V
12V
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or remote control are prohibited, except for changing the code setting or replacing the battery. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
ACCESSORY WIRING
REMOTELY MOUNTED STOP/RESET CONTROL WIRING · This control will function as a Stop/Reset command and is to be wired within line of sight of the gate. · Wire Stop/Reset control station to terminals 3 and 5 on the control box on the operator. Make sure that all Stop/Reset controls are wired in series.
NORM
HIGH
1 234567
Control Conduit Control Conduit
1
2
3
Terminals 6 & 5 (Com) - Soft Open These terminals are intended for use as a general open control. Accessories that may be wired to this input include: Telephone Entry Systems, Radio Receiver (Commercial Applications), Exit Loop Detector, Keypads, 7-Day Timer. NOTE: Will not override a double entrapment (signalled by the gate stopped and entrapment alarm on).
Stop/Reset Button 1
Stop/Reset Button
234
5
6
7
8 9 10 11 12 13 14
123 56 789 0#
Soft Open
19
M
ACCESSORY WIRING (CONTINUED)
Terminals 7 & 5 (Com) - Hard Open Override Control Input These terminals are intended for use only with the open control of a 3-button station that is installed within line of sight of the gate. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo-eye. Terminals 4 & 5 (Com) - Close Override Control Input These terminals are intended for use only with the close control of a 3-button station that is installed within line of sight of the gate. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo-eye. Terminals 8 & 5 (Com) - Interrupt (Safety) Loop Input These terminals are intended for use with a loop detector. Terminals 2 & 5 (Com) - Shadow Loop Input These terminals are intended for use with a loop detector and is primarily used on swing gate operators. This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. Commands are seen when +24Vdc is applied to the controller's input terminals. NOTE: The control board has built in surge suppression circuitry however please take precautions when adding any additional surge protection. MASTER/SECOND SYSTEMS Dual Gate Communications The control board is capable of running the operator in a master or second mode depending on (S4) switch setting. Before initiating any command the master unit queries for the presence of a "second unit" for a time period of one second. If the master gets no response the operator will operate in a stand alone mode. [. . . ] Please allow additional delivery time.
37
SAFETY ACCESSORIES FOR SECONDARY ENTRAPMENT PROTECTION
The following devices are acceptable for Safety Accessories for secondary entrapment protection.
PHOTO-ELECTRIC CONTROLS MODEL CPS-N4 AOMRON MODEL G65MG0204 G65MG0205 G65ME12C5 G65MGR205 G65MGS205 DESCRIPTION Emitter, receiver and mounting brackets - 30' (9 m) Maximum Range Photocell/Electric Eye - 30' (9 m) Maximum Range SENSING EDGES DESCRIPTION Miller MG020 2-wire electric edge for gates. Miller MGR20 2-wire electric edge in 5' (1. 5 m) lengths for 2" (5 cm) round post. Miller MGR20 2-wire electric edge in 5' (1. 5 m) lengths for 2" (5 cm) square post. VOLTAGE +24V ac/dc +24V ac/dc VOLTAGE +24V ac/dc +24V ac/dc
+24V ac/dc +24V ac/dc
38
NOTES
39
WARRANTY POLICY AND SERVICE
LIFTMASTER® TWO YEAR LIMITED WARRANTY
The Chamberlain Group, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN SL585
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN SL585 will begin.