User manual CHAMBERLAIN SLY2500

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAMBERLAIN SLY2500. We hope that this CHAMBERLAIN SLY2500 user guide will be useful to you.


CHAMBERLAIN SLY2500 : Download the complete user guide (718 Ko)

Manual abstract: user guide CHAMBERLAIN SLY2500

Detailed instructions for use are in the User's Guide.

[. . . ] Gate weight: Specification of gate weight represents only a rough parameter, which can vary according to actual demand. Influence of temperature: Low outdoor temperatures can impede or even prevent starting torque (ground deformation etc. ). High outdoor temperatures can lead to premature initiation of temperature protection switch. Notice: Motors are not designed to run permanent run (continuous operation). [. . . ] For two rack mounting the M8 screw must be replaced with a longer type to suit the application. DRIVE RELEASE MECHANISM (MANUAL OPERATION) The drive is equipped with a lockable release mechanism to enable the gate to be operated manually during a power out. Turn opening lever into position Disengage gear: Turn knob fully inside (clockwise). Notice: For full engagement of gear it is important to turn the knob completely outside (anti-clockwise). FITTING LIMIT SWITCHES (TO GATE) · The drive should be disengaged before this part of the assembly work is carried out. · Mount the limit switch bracket such that the roller of the first switch is situated approximately in the middle of the bracket. INITIAL OPERATION Check gate functionality manually when the drive has been disengaged. Electrical operation is possible only if a controller (CB400) is connected. ELECTRICAL CONNECTION: See electrical wiring diagram with control board CB400 · Control board pre-installed · Limit switch pre-wired to NC contacts · Motor pre-wired to control board box · Control board box pre-installed Always ensure that the mechanical and electrical safety requirements relevant to the given system are complied with. A sliding gate can also be secured by implementing on-site measures (fence, wall, etc. ). MAINTENANCE WORK (monthly) The drive mechanics are generally maintenance-free. Check at regular intervals that the gate hardware and the drive are all firmly in place. · Inspect for damage to electrical wiring Declaration of Conformity Automatic Gate Opener Models. . . . . . . . . SLY2500 are in conformity to the applicable sections of Standards: EN55014 · EN61000-3 · EN60555, EN60335-1 · ETS300 683 · EN60335-1: 2002 · EN60335-2-103: 2003 · EN55014-1: 2000 + A1 + A2 · EN55014-2: 2001 · EN61000-3-2: 2000 · EN61000-3-3: 1995 + A1 · EN 301 489-3, V1. 3. 1 · EN13241-1 per the provisions & all amendments of the EU Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2006/95/EC, 2004/108/EC, 1999/5/EG Declaration of Incorporation Automatic Gate Opener Models , when installed and maintained according to all the Manufacturer's instructions in combination with a Gate, which has also been installed and maintained according to all the Manufacturer's instructions, meets the provisions of EU Directive 89/392/EEC and all amendments. I, the undersigned, hereby declare that the equipment specified above and any accessory listed in the manual conforms to the above Directives and Standards. Harry Naumann Manager, Regulatory Affairs Chamberlain GmbH D-66793 Saarwellingen Germany October, 2008 CONTROL BOARD KIT CB400 for AC SLIDING GATE OPERATORS -Installation Instructionswww. liftmaster. de Email: info@chamberlain. de Chamberlain GmbH Alfred Nobel Strasse 4 D-66793 Saarwellingen Germany This product may only be installed from professional installers. Only qualified and trained electricians may connect, programme and service the controls. Qualified and trained electricians meet the following requirements: - have knowledge of the general and specific safety and accident prevention regulations, - have knowledge of the relevant electrical regulations, - are trained in the use and care of appropriate safety equipment, - are capable of recognising the dangers associated with electricity. Attention: Scope of these instructions: These instructions describe the installation and options for the product CB400 (control board AS210B): Some features require the optional ZM-SKS plug in logic board to work. This manual should only be used together with SLY2500 and SLY3500 operators!For mechanical installation of the operator use the instruction included with the operator. FEATURES Type of gate motor used Motor Voltage Controller (CB400 kit) Max. Gate weight (kg) Motor Protection Switch Thermal protection (internal) Hold to run function Automatic function IR-Sensor Radio Automatic close Flashing Light Safety edges Emergency Stop External Light switching function Traffic light with Red-Light SLY2500 230Volt AS210B 2500kg no yes yes yes yes external yes* yes* yes* yes* yes* yes* SLY3500 400Volt AS210B 3500kg yes no yes yes yes external yes* yes* yes* yes* yes* yes* * requires ZM-SKS-B plug in card IMPORTANT: BEFORE the installation of control board make sure it is checked if your control motor requires to be set for 400Volt, 3-Phase or 230Volt, 1-Phase (X4 terminal). A. X1: X2: X3: X4: X5: Test button OPEN direction (S01) / Test button CLOSE direction (S02) Terminals Terminals Terminals Terminals Terminals Mains Motor / safety circuit of drive Command devices Selection 230V / 400V Limit switches Terminals for 3-way switch Plug-in socket for ZM-SKS-B circuit card Plug-in socket for spiral cable Terminals for traffic light / yard light (only in connection with a ZM SKS B plugin circuit card) X10: Terminals for press-and-release CLOSE- OPEN X11: Not used X6: X7: X8: X9: Installation of control board: The assembly instructions assume that there is no control board pre-installed. [. . . ] For relay photocell with 4-wire technology OPENING direction Terminal 14+15: Signal Terminal 5 : + 24VDC Terminal 6 : - 24VDC MORE OPTIONS: · For Chamberlain 2-wire photocells the optional 600213-2 interface box is required. 230V AC / 4A. Contacts used once for power switching can not be subsequently used for connecting small currents. 1. 8 kg Standards Control outputs: Safety circuit / emergency off: Input -safety contact edge:* Declaration of Conformity Gate Control Board for SLY2500 and 3500. . . . . . . . . AS210B is in conformity to the applicable sections of Standards: EN55014 · EN61000-3 · EN60555, EN60335-1 · ETS300 683 · EN60335-1: 2002 · EN60335-2-103: 2003 · EN55014-1: 2000 + A1 + A2 · EN55014-2: 2001 · EN61000-3-2: 2000 · EN61000-3-3: 1995 + A1 · EN 301 489-3, V1. 3. 1 · EN13241-1 per the provisions & all amendments of the EU Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2006/95/EC, 2004/108/EC, 1999/5/EG Automatic Gate Opener Models , when installed and maintained according to all the Manufacturer's instructions in combination with a Gate, which has also been installed and maintained according to all the Manufacturer's instructions, meets the provisions of EU Directive 89/392/EEC and all amendments. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN SLY2500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN SLY2500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.