User manual CISSELL MUMAN196

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL MUMAN196. We hope that this CISSELL MUMAN196 user guide will be useful to you.


CISSELL MUMAN196 : Download the complete user guide (1327 Ko)

Manual abstract: user guide CISSELL MUMAN196

Detailed instructions for use are in the User's Guide.

[. . . ] For warranty service, contact the Distributor from whom the Cissell equipment or part was purchased. If the Distributor cannot be reached, contact Cissell. Page 2 TABLE OF CONTENTS MU42 and MU45 (UTILITY) PAGE Warranty. . 6 7 9 9 Operation of the Press 9 Overview of the Press . . . . . . . . . . . . . . . . . . . Lower Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Vacuum Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Boiler Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 11 14 15 16 17 18 19 20 21 22 23 24 24 25 26 27 Page 3 TABLE OF CONTENTS MU42, MU45, UTILITY PAGE Buck Steam Linkage 20 General Trouble Shooting 12 Head will not lock Press Head bangs down when released . No vacuum Vacuum will not shut off Buck Steam Valve releases too much or too little steam Wet spots on buck pad and covering Defective check valve Buck Valve leaking externally Head Valve leaking externally No head steam 12 12 12 13 13 13 13 13 13 13 Page 4 TESTING This press has been tested in the Cissell factory to determine that it is safe and in working order. Final adjustments must be made to obtain the best results for your garments using your steam and vacuum in your environment. The Cissell presses are manufactured and tested to the highest standards. The steam pressure vessels have been tested with liquid to a pressure of 250 psi (17 bars). They have been tested for leaks with live steam at a pressure of 88 psi (6 bars). On request, we can supply pressure certification and information regarding sizes and wall thickness of the vessel(s). FOREWORD Manual Foot Operated Presses These modern presses are precision engineered to provide faster, easier operation than any other foot operated press. The head is closed by hand and by foot operation of the central pedal. Head Valve This valve is equipped with an adjusting screw to meter the flow of head steam. Buck Steam Linkage shows the linkage needed for buck steam operation. With no pressure on the foot pedal turn this rod counterclockwise as viewed from the top so that no steam flows into buck. Depression of the right hand pedal should then give a good flow of steam. If there is poor steam flow because the pedal can not travel far enough, then turn the valve lever rod clockwise. Buck Valve This valve is set at the factory and normally would not be adjusted. Head Will Not Lock__________________________________________________________________ Cause Remedy A. Once per month add ordinary lubricating oil into the oil holes of the foot pedals. The main pivot of the press head lever is fitted with pillow block bearings that are factory lubricated Lubricate linkage as needed with ordinary oil. Press Head Stays Down When Released_______________________________________________________ Cause Remedy A. Rear springs has gotten out of adjustment Re-adjust spring support plate. 3. No Vacuum_________________________________________________________________________ Cause Remedy A. [. . . ] Rear springs has gotten out of adjustment Re-adjust spring support plate. 3. No Vacuum_________________________________________________________________________ Cause Remedy A. The set collar on the vacuum valve connecting rod not adjusted properly. Adjust set collar for a clearance of +/- 1/16 inch between collar and operating valve lever. Page 12 4. Vacuum Will Not Shut Off____________________________________________________________ Cause Remedy A. Repair or replace vacuum valve. 5. Wet Spots On Buck Pad & Covering_____________________________________________________ Cause Remedy A. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL MUMAN196




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL MUMAN196 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.