User manual CONTAX T240 REV B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONTAX T240. We hope that this CONTAX T240 user guide will be useful to you.


CONTAX T240 REV B: Download the complete user guide (3094 Ko)

Manual abstract: user guide CONTAX T240REV B

Detailed instructions for use are in the User's Guide.

[. . . ] Autotransformer T240 Installation and Operation Guide ã2000 Trace Engineering P/N 975-0002-01-02 Rev. B 04/00 ©2000 Trace Engineering T240 Autotransformer Table of Contents Section 1. Description Page INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 The T240 Autotransformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Pull back the insulation on the TRANSFORMER wire so it is exposed inside the service crimp. Strip off approximately 1/2 inch of the insulation from the wire to be installed and insert the bare wire into the crimp. Slide the crimp up to the circuit breaker terminal as far as it will go. Place the wire in the crimp and ensure the existing wires insulation is fully exposed. After torquing, ensure the service crimp is tight on both wires and is not able to twist or be moved. CAUTION: UNUSED SERVICE CRIMPS SHOULD BE TIGHTENED TO THE EXISTING WIRE AND TAPED, SO IT CAN NOT SHORT TO OTHER TERMINALS OR THE CASE. Breaker Lug Service Crimp Added LOAD Wire Existing Factory Wiring 975-C00-004 Figure 4 Installation Drawing 4 ©2000 Trace Engineering 2. 0 INSTALLATION Connection Points The connection points for input/output wiring is as follows: All 240 volt AC (input or output) wires connect to the left-hand side of the breaker, points A and C (Figures 6 and 7). All 120 volt AC wires connect to the service crimps located on the breaker, points B and D (Figures 6 and 7). The ganged circuit breaker used in the T240 opens both circuit breakers if either one receives a current draw in excess of its rating (i. e. , 25 amps). NOTE: Due to continued product improvement, parts availability, etc. , photographs used in this manual may vary slightly from actual current production models. GROUND block NEUTRAL block 240 Volt AC Input/Output 120 Volt AC Input/Output service crimps Factory Wiring DO NOT REMOVE OR ADD WIRES TO THESE TERMINALS! Figure 5 Step-up Configuration Connections ©2000 Trace Engineering 5 2. 0 INSTALLATION Connection Identification Points (continued) Figures 6 and 8 identify the wiring points in the T240 Autotransformer: A B C D GROUND Only 240 volt AC (L1) input/output connections are made on this circuit breaker terminal. Only 240 volt AC (L2) input/output connections are made on this circuit breaker terminal. All ground wires connect to this block for both source and load. NEUTRAL This is the neutral block contained in the T240. All neutral wires connect to this block for both source and load (except as noted in the procedures). GROUND C D NEUTRAL A B Figure 6 Connection Point Identification 6 ©2000 Trace Engineering 2. 0 INSTALLATION Upper Breaker Service Crimp L2 C D Neutral Block NEUTRAL Lower Breaker L1 B Service Crimp GROUND Ground Block A 975-S00-002A Figure 7 Connection Point Identification Schematic ©2000 Trace Engineering 7 2. 0 INSTALLATION Step-up Configuration This configuration allows for a 240 volt AC load to be supplied from a 120 volt AC input source. The voltage output of the autotransformer doubles (from 120 to 240 volts AC) and the total output current available is one half. Procedure The wire terminals accept wire sizes from #14 AWG to #2 AWG. 120 Volt AC Input (source) NOTE: Refer to the previous instructions on connecting wires to the service crimp. Connect the 120 volt AC HOT wire (from an inverter, generator or utility) to service crimp (point B) of the breaker as shown in Figure 8. Connect a white wire from the NEUTRAL block in the autotransformer to the pumps neutral connection. Connect a green wire from the GROUND block in the autotransformer to the pumps ground connection. L2 OUT D C L2 Service Crimp N N NEUTRAL N 120 VAC Source L1 OUT L2 240 VAC G Deep Well N Pump L1 A B Service Crimp L1 G Ground Control Switch G HOT 975-S00-005 Figure 9 Control Switch Wiring for Deep Well Pump ©2000 Trace Engineering 9 2. 0 INSTALLATION 240 Volt AC Source120 Volt AC to Loads (Step-down Configuration) This configuration allows a 120 volt AC load to be supplied from a 120/240 volt AC input source such as a utility grid. The voltage output of the autotransformer halves (from 240 to 120 volts AC) and the total output current available for the 120 volt AC output doubles. This arrangement is useful for splitting the current of a battery charger between each leg of the 240 volt AC source, reducing losses in the wiring. This is especially important in long cable runs or when charging from a 120/240 volt AC output generator. 240 Volt AC Input (source) Connect the L1 AC HOT wire (from the utility grid) to point A on the lower breaker as shown in Figure 10. Connect the L2 AC HOT wire (from the utility grid) to point C on the upper breaker as shown in Figure 10. [. . . ] The example below shows these additional breakers used to protect and control six 120 volt AC loads. Different circuit configurations can be arranged depending upon your powering needs. HOT 120 VAC Load N G HOT 120 VAC Load N G HOT L2 L2 240 VAC Source C D 120 VAC Load N G NEUTRAL HOT 120 VAC Load N G L1 HOT N G L1 A B G GROUND G 120 VAC Load HOT 120 VAC Load N G 975-S00-010 Figure 14 Step Down Arrangement Using Optional Breakers NOTE: Provisions for connecting the additional neutral wires may need to be added. NOTE: The T240 has not been listed with UL with additional breakers installed. 16 ©2000 Trace Engineering 2. 0 INSTALLATION Wiring Check Before powering the T240 Autotransformer, recheck all wiring and ensure it is connected to the proper terminals of the breaker or service crimps. Check that the ground and neutral connections are properly wired and tight. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX T240




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONTAX T240 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.