If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 16 MODEL. We hope that this CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 16 MODEL user guide will be useful to you.
Manual abstract: user guide CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 16 MODEL
Detailed instructions for use are in the User's Guide.
[. . . ] Culligan® Advanced Platinum Plus Series Automatic Water Conditioner Owners Guide
Thank You And Welcome To Your New World Of Better Living With Culligan Water.
The Culligan Advanced Platinum Plus Series Water Softeners with Soft-Minder® Meter and Aqua-Sensor® sensing device are tested and certified by WQA against NSF/ANSI Standard 44 for the effective reduction of hardness (calcium and magnesium), barium and radium 226/228 as verified and substantiated by test data. For installations in Massachusetts, Massachusetts Plumbing Code 248 CMR shall be adhered to. This system and its installation must comply with state and local regulations. If this is your first experience having soft, conditioned water in your home, you'll be amazed at the marvelous difference it makes. [. . . ] Press DOWN arrow to view the next screen.
remaining capacity
98%
Total Capacity
891 Gallons
Salt Used
27. 0 LBS
Current Flow Rate
5. 0 GPM
Today's USage
200 Gallons
Average Daily
300 Gallons
Next Regen on
Jan-03
Total Water Used
1000 Gallons
Ext Filt Cap Rem
98000 Gallons
Continue to press the X to return to the HOME screen. 29
Final Start-up
Manual Regeneration
Follow the procedure below to initiate a manual regeneration at the control valve or the remote display.
Filtering
JAN-01-09 12:01 A
1) information > 2) manual mode 3) set date/time 4) Accessories
Press DOWN arrow.
Pressing the CHECK MARK button will change the display to show a ">" symbol next to the displayed value.
Manual Mode
>Regen OFF
The "REGEN OFF" value is the default setting.
Use the UP or DOWN arrow to change the setting. Once the desired value is displayed, this value can be accepted by pressing the "CHECK MARK" button.
Manual Mode
Regen tonite
Manual Mode
By selecting the "REGEN TONITE" value the softener will regenerate that night at 2:00 AM (or at the preset regeneration time)
Regen now
By selecting the "REGEN NOW" value the softener will begin regeneration immediately.
Press the "CANCEL" button to return to the "home" screen.
30
Regeneration
There are several conditions that will cause the control to trip a regeneration. The "REGEN TONITE" will be displayed when the control has signaled for a regeneration. The "REGENERATING" will be displayed while the control is in regeneration. When the Soft-Minder ® meter has recorded the passage of a predetermined number of gallons. When the Aqua-Sensor ® Probe senses the hardness in the Cullex Media. At the preset time, when the number of days without a regeneration is equal to the Timeclock Backup setting. Immediately, if power to the unit has been off for more than 3 hours and time of day has been restored.
Final Start-up (Cont. )
Recommended Meter Start-Up Procedure
· · · · · · · · · · · · Close the main water supply valve. Direct the drain line discharge into a bucket where flow can be observed. Initiate an immediate regeneration to move the control into the backwash position. Refer to the section on manual cycling for information on cycling the control through its positions. When in the backwash position, slowly shift the bypass to the soft water position until water flows. Increase the flow again when resin no longer appears in the discharge. When the unit is filled with water, return the timer to the service position. Sanitize the unit as you leave the installation site (See Sanitizing Procedure on page 36). Note: Unplugging the Culligan Advanced Platinum Plus SeriesTM water softener will not affect any of the control settings (the control must be plugged in for at least 10 minutes). Once programmed in, the settings will be stored indefinitely.
· ·
31
Final Start-up (Cont. )
Recommended Aqua-Sensor® Start-Up Procedure
· · · · · · · · · · · · Close the main water supply valve. Install the sensor probe into the tank but do not connect the sensor to the control at this time. Direct the drain line discharge into a bucket where flow can be observed. Plug the transformer into a 120 Volt, 60 Hz, single-phase receptacle (make sure to connect both 24V and 2. 5V properly). Initiate an immediate regeneration to move the control into the backwash position. [. . . ] As an expression of our confidence in Culligan International Company products, your water conditioner is warranted to the original end-user, when installed in accordance with Culligan specifications, against defects in material and workmanship from the date of original installation, as follows: For a period of ONE YEAR For a period of FIVE YEARS The entire conditioner Soft-Minder® meter, Aqua-Sensor® probe, Remote Display, Modem, and Smart Brine Tank probe if so equipped. The GBE circuit board, The control valve body, excluding internal parts. The salt storage container, brine valve and all its component parts For the LIFETIME of the The Quadra-HullTM conditioner tank original consumer purchaser and the Cullex® resin
If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 16 MODEL
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 16 MODEL will begin.