User manual DAIKIN ALTHERMA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAIKIN ALTHERMA. We hope that this DAIKIN ALTHERMA user guide will be useful to you.


DAIKIN ALTHERMA : Download the complete user guide (1141 Ko)

You may also download the following manuals related to this product:

   DAIKIN ALTHERMA (7685 ko)

Manual abstract: user guide DAIKIN ALTHERMA

Detailed instructions for use are in the User's Guide.

[. . . ] explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N. V. . " ISO14001 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N. V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Zandvoordestraat 300 B - 8400 Ostend Belgium www. daikineurope. com EEDE0 6 - 9 EEDE06-9 - 07/2006 Printed in Belgium by Goekint Graphics EEDE06-9 technical data Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW150-300 · Chillers · R-410A · ALTHERMA erA el0 hl1 t4i l-h RAC Cooling only Heating only Heat pump 4 · Altherma · Chillers · Outdoor units · R-410A · ERYQ TABLE OF CONTENTS ERYQ 1 2 Features . [. . . ] Water side Heat exchanger Expansion vessel Cooling Heating l/min l/min 16. 5 19. 6 24. 2 14. 7 16. 5 16. 5 19. 6 17. 6 24. 2 Insulation material Polyurethane foam Volume Max. water pressure Pre pressure l bar 10 3 bar mm 1 1 Water filter Diameter perforations Material Brass inch inch bar 1"MBSP 1"MBSP 3 Yes Yes Yes Yes Water circuit Piping connections diameter Piping Safety valve Manometer Drain valve / Fill valve Shut off valve Air purge valve · Altherma · Indoor units 21 · Indoor units · R-410A · EKHBH / EKHBX 2 2-1 Specifications TECHNICAL SPECIFICATIONS Gas side diameter Liquid side diameter Sound Pressure Waterside Cooling Heating mm mm dBA °C °C EKHBH007A (+ERYQ005A) EKHBH007A (+ERYQ006A) EKHBH007A (+ERYQ007A) EKHBX007A (+ERYQ005A) EKHBX007A (+ERYQ006A) EKHBX007A (+ERYQ007A) Refrigerant Circuit 15, 9 (2) 27 7 ~ 20 30 ~ 55 The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. ERYQ = 6. 35 mm EKHB = 9. 52 mm (flare connection) 2 2 Sound Level Operation range Notes 22 · Altherma · Indoor units · Indoor units · R-410A · EKHBH / EKHBX 2 2-2 Electric heater Specifications ELECTRICAL SPECIFICATIONS Type Power Supply Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Hz V A Hz V A Hz V A Hz V A Hz V A Hz V A EKHBH007A (+ERYQ005A) EKHBH007A (+ERYQ006A) EKHBH007A (+ERYQ007A) EKHBX007A (+ERYQ005A) EKHBX007A (+ERYQ006A) EKHBX007A (+ERYQ007A) 3V3 1 50 230 13 6V3 1 50 230 26 6W1 3N 50 400 8. 6 6T1 3 50 230 15 9W1 3N 50 400 13 9T1 3 50 230 23 2 2 Electric heater Type Power Supply Electric heater Type Power Supply Electric heater Type Power Supply Electric heater Type Power Supply Electric heater Type Power Supply · Altherma · Indoor units 23 3 24 2 3 Optional equipment for EKHB(H/X)007* Reference EKHBH007A3V3 EKHBX007A3V3 EKHBH007A6V3 EKHBX007A6V3 EKHBH007A6W1 EKHBX007A6W1 EKHBH007A6T1 EKHBX007A6T1 EKHBH007A9W1 EKHBX007A9W1 EKHBH007A9T1 EKHBX007A9T1 Description Number Availability Heating only model Reversible model Available options V V V V V V Factory mounted Factory mounted Factory mounted Factory mounted Factory mounted Factory mounted Options 3V3 Back up heater 3kW 1230 V 6V3 Back up heater 6kW 1230 V 6W1 Back up heater 6kW 3400 V + N 6T1 Back up heater 6kW 3230 V 9W1 Back up heater 9kW 3400 V + N 9T1 Back up heater 9kW 3230 V Available kits V V V V V V V V V V V V V V V V V V V V V V Kit Kit Kit Kit Kit · Altherma · Indoor units EKSWW150V3 Sanitary warm water tank 150 l 230 V EKSWW200V3 Sanitary warm water tank 200 l 230 V EKSWW300V3 Sanitary warm water tank 300 l 230 V EKSWW200Z2 Sanitary warm water tank 200 l 400 V · Indoor units · R-410A · EKHBH / EKHBX EKSWW300Z2 Sanitary warm water tank 300 l 400 V EKWBSWW150 Wall bracket for EKSWW150V3 Kit 3TW56719-5 · Indoor units · R-410A · EKHBH / EKHBX 4 4-1 Dimensional drawing & centre of gravity Dimensional drawing EKHBH-A 2 4 Service door (Closed) 361 (Open) 553 Minimum space for service & ventilation Min. 200 Center of gravity j Pump + switch for speed setting 1 j Remocon 2 j Water IN conection 1'' M BSP 3 j Water OUT connection 1'' M BSP 4 j Power supply intake (+ sanitary warm water tank) 5 j Drain / fill valve 6 j Air purge 7 j Expansion vessel + nipple 8 j Blow off valve 9 j Pressure gauge 10 j Water filter 11 j Suction pipe connection J15. 9 flare connection 12 j Liquid pipe connection J9. 52 flare connection 13 j Shut off valves (delivered with unit) 14 j Thermistor connection (+ sanitary warm water tank) 15 j Holes for fixation 16 j Blow off drain 17 j Switchbox connection terminals 18 j Wallbracket 19 1'' female BSP 1'' male BSP Setup 1 Setup 2 A 200 350 B 400 200 Min. 200 Center of gravity j Pump + switch for speed setting 1 j Remocon 2 j Water IN conection 1'' M BSP 3 j Water OUT connection 1'' M BSP 4 j Power supply intake (+ sanitary warm water tank) 5 j Drain / fill valve 6 j Air purge 7 j Expansion vessel + nipple 8 j Blow off valve 9 j Pressure gauge 10 j Water filter 11 j Suction pipe connection J15. 9 flare connection 12 j Liquid pipe connection J9. 52 flare connection 13 j Shut off valves (delivered with unit) 14 j Thermistor connection (+ sanitary warm water tank) 15 j Holes for fixation 16 j Blow off drain / drain of drainpan 17 j Switchbox connection terminals 18 j Wallbracket 19 1'' female BSP (Closed) 461 (Open) 653 1'' male BSP Dimensions wallbracket Min. 400 Setup 1 Setup 2 A 200 350 B 400 200 3TW56724-1A · Altherma · Indoor units 25 · Indoor units · R-410A · EKHBH / EKHBX 5 EKHB-A Piping diagram Water side 2 5 R4T R3T R2T R1T Inlet water thermistor Refrigerant liquid side thermistor Outlet water backup heater thermistor Outlet water heat-exchanger thermistor Field installation Filter Inlet Shut off valve Refrigerant side Pressure gauge Drain valve Safety valve Drain Expansion vessel Cooling (EKHBX) Heating (EKHBX + EKHBH) Drain valve Air purge Pump Option backup heater Field installation Flowswitch Outlet Overview Electric heater body Refr. out Outdoor unit Shut off valve Evaporator Condensor Water inlet Refr. out O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe PSpinned pipe 3TW56715-1 26 · Altherma · Indoor units · Indoor units · R-410A · EKHBH / EKHBX 6 6-1 Wiring diagram Wiring diagram Power supply >> See note 2 << Only for EKSWW option Outdoor unit Sanitary tank EKHBH/X-A3V3 2 6 Only for EKHB*00*A3V3 or6V3 Only for EKSWW option User interface V2S V1S FU1 R1T (A2P) Q1DI Q2L Q1L TR1 R5T R4T R3T R2T R1T (A1P) S1L E4H E3H E2H E1H M3S M2S M1P K3M K2M K1M F2B F1B A3P A2P A1P : Spark suppression 2 : Spark suppression 1 : Fuse 3. 15A T 250V : Thermistor (air) : Earth leakage protector : Thermal protector booster heater : Thermal protector backup heater : Transformer 24V for PCB : SWW Thermistor : Inlet water thermistor : Refrigerant liquid side thermistor : Outlet water backup heater thermistor : Outlet water heat-exchanger thermistor : Flowswitch : Booster heater : Backup heater element 3 : Backup heater element 2 : Backup heater element 1 : 3 way valve floorheating / sanitary warm water : 2 way valve for cooling mode : Pump : Contactor booster heater : Contactor backup heater Step 2 : Contactor backup heater Step 1 : Fuse booster heater : Fuse backup heater : Thermostat (field supply, PC = interval power circuit) : Remocon PCB : Main PCB Only for EKHB*00*A6V3 NO valve Only for EKSWW option supply from PCB Only for EKHB*00*A3V3 model F1B model F2B Electric heater option fuse 3V3 20A EKSWW kit fuse 20A Sanitary tank Only for EKSWW option Only for EKHB*00*A3V3 Thermostat On/Off NC valve heating cooling Wiring dependent on model Option Field wiring Wire colour Notes: 1 This wiring diagram only applies to the indoor unit. 2 Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option 3 :Field wiring 4 :Terminal strip :Connector :Terminal :Protective earth 5 Do not operate the unit by short-circuiting protection devices Q1L, Q2L, S1L. 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW56716-4A EKHBH/X-A6V3 Power supply >> See note 2 << Only for EKSWW option Outdoor unit Sanitary tank Only for EKSWW option User interface X1M V2S V1S FU1 R1T (A2P) Q1DI Q2L Q1L TR1 R5T R4T R3T R2T R1T (A1P) S1L E4H E3H E2H E1H M3S M2S M1P K4M K3M K2M K1M F2B F1B A3P A2P A1P : Terminal block : Spark suppression 2 : Spark suppression 1 : Fuse 3. 15A T 250V : Thermistor (air) : Earth leakage protector : Thermal protector booster heater : Thermal protector backup heater : Transformer 24V for PCB : SWW Thermistor : Inlet water thermistor : Refrigerant liquid side thermistor : Outlet water backup heater thermistor : Outlet water heat-exchanger thermistor : Flowswitch : Booster heater : Backup heater element 3 : Backup heater element 2 : Backup heater element 1 : 3 way valve floorheating / sanitary warm water : 2 way valve for cooling mode : Pump : Contactor backup heater : Contactor booster heater : Contactor backup heater Step 2 : Contactor backup heater Step 1 : Fuse booster heater : Fuse backup heater : Thermostat (field supply, PC = interval power circuit) : Remocon PCB : Main PCB Only for EKSWW option NO valve heating cooling 230V AC supply from PCB model F1B model F2B Electric heater option fuse 6V3 32A EKSWW kit fuse 20A Sanitary tank Only for EKSWW option Thermostat On/Off NC valve Wiring dependent on model Option Field wiring Wire colour Notes: 1 This wiring diagram only applies to the indoor unit. 2 Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option 3 :Field wiring 4 :Terminal strip :Connector :Terminal :Protective earth 5 Do not operate the unit by short-circuiting protection devices Q1L, Q2L, S1L. 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW56716-5 · Altherma · Indoor units 27 · Indoor units · R-410A · EKHBH / EKHBX 6 6-1 Wiring diagram Wiring diagram Power supply >> See note 2 << Outdoor unit Sanitary tank EKHBH/X-A6W1/9W1 2 6 Only for EKSWW option Only for EKSWW option X1M V2S V1S FU1 R1T (A2P) Q1DI Q2L Q1L TR1 R5T R4T R3T R2T R1T (A1P) S1L E4H E3H E2H E1H M3S M2S M1P K4M K3M K3M K2M K1M F2B F1B A3P A2P A1P : Terminal block : Spark suppression 2 : Spark suppression 1 : Fuse 3. 15A T 250V : Thermistor (air) : Earth leakage protector : Thermal protector booster heater : Thermal protector backup heater : Transformer 24V for PCB : SWW Thermistor : Inlet water thermistor : Refrigerant liquid side thermistor : Outlet water backup heater thermistor : Outlet water heat-exchanger thermistor : Flowswitch : Booster heater : Backup heater element 3 : Backup heater element 2 : Backup heater element 1 : 3 way valve floorheating / sanitary warm water : 2 way valve for cooling mode : Pump : Contactor backup heater : Contactor booster heater : Contactor booster heater : Contactor backup heater Step 2 : Contactor backup heater Step 1 : Fuse booster heater : Fuse backup heater : Thermostat(Field supply) : Remocon PCB : Main PCB User interface NO valve heating cooling Only for EKSWW option 230V AC supply from PCB model F1B model F2B Electric heater option fuse 6W1 9W1 13A 16A EKSWW kit fuse 20A Thermostat On/Off Sanitary tank Only for EKSWW*V3 Option Sanitary tank Only for EKSWW*Z2 Option NC valve Wiring dependent on model Option Field wiring Wire colour Notes: 1 This wiring diagram only applies to the indoor unit. 2 Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option 3 :Field wiring 4 :Terminal strip :Connector :Terminal :Protective earth 5 Do not operate the unit by short-circuiting protection devices Q1L, Q2L, S1L. 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW56716-2B EKHBH/X-A6T1/9T1 Power supply >> See note 2 << Only for EKSWW option Outdoor unit Sanitary tank Only for EKSWW option User interface X1M V2S V1S FU1 R1T (A2P) Q1DI Q2L Q1L TR1 R5T R4T R3T R2T R1T (A1P) S1L E4H E3H E2H E1H M3S M2S M1P K4M K3M K2M K1M F2B F1B A3P A2P A1P : Terminal block : Spark suppression 2 : Spark suppression 1 : Fuse 3. 15A T 250V : Thermistor (air) : Earth leakage protector : Thermal protector booster heater : Thermal protector backup heater : Transformer 24V for PCB : SWW Thermistor : Inlet water thermistor : Refrigerant liquid side thermistor : Outlet water backup heater thermistor : Outlet water heat-exchanger thermistor : Flowswitch : Booster heater : Backup heater element 3 : Backup heater element 2 : Backup heater element 1 : 3 way valve floorheating / sanitary warm water : 2 way valve for cooling mode : Pump : Contactor backup heater : Contactor booster heater : Contactor backup heater Step 2 : Contactor backup heater Step 1 : Fuse booster heater : Fuse backup heater : Thermostat(Field supply) : Remocon PCB : Main PCB NO valve heating cooling Only for EKSWW option 230V AC supply from PCB model F1B model F2B Electric heater option fuse 6T1 9T1 20A 32A EKSWW kit fuse 20A Thermostat On/Off NC valve Sanitary tank Only for EKSWW option Wiring dependent on model Field wiring Option Wire colour Notes: 1 This wiring diagram only applies to the indoor unit. 2 Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option 3 :Field wiring 4 :Terminal strip :Connector :Terminal :Protective earth 5 Do not operate the unit by short-circuiting protection devices Q1L, Q2L, S1L. 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW56716-3B 28 · Altherma · Indoor units · Indoor units · R-410A · EKHBH / EKHBX 6 6-2 EKHB-A Wiring diagram External connection diagram Standard parts Power supply Outdoor unit Unit power supply: 230V + earth Backup heater power supply (3/6/9kW): 400V or 230V + earth 3 core X1M:L-N-Earth For more details please check unit wiring diagram 2 6 Optional power supply Booster heater power supply (3kW): 400V or 230V + earth X2M:1-2-3-Earth 4 core 3 or 4 core 3 core Optional parts Field supply X1M:9-10-11-Earth Sanitary tank Room thermostat Power supply booster heater 4 core 5 core X1M:7-8-Earth A3P (optional) Q2L - Clixon booster heater 230V or 400V NO valve: NC valve: 2 core 2 way valve M2S (EKHBX Units) for cooling mode R5T - Thermistor water temperature 2 core Signal Thermistor cable Note: min. distance to power cable = 3cm 2 core 3 way valve M3S (when EKSWW is installed) selection sanitary-floorheating Indoor unit User interface 3TW56719-6 · Altherma · Indoor units 29 · Indoor units · R-410A · EKHBH / EKHBX 7 7-1 Hydraulic performance Static pressure drop unit 2 7 ESP = f (Flow) ESP [mH2O] Flow (l/min) I: low speed setting pump II: medium speed setting pump III: high speed setting pump ESP: External static pressure Flow: waterflow trough the unit Warning: Selecting a flow outside the curves can cause damage to or malfunction of the unit. See also minimum and maximum allowed water flowrate in the technical specifications. 4TW56749-2 30 · Altherma · Indoor units · Sanitary Hot Water · R-410A · EKSWW TABLE OF CONTENTS EKSWW 1 2 Features . . 36 · Altherma · Sanitary Hot Water 31 · Sanitary Hot Water · R-410A · EKSWW 1 o H y a r m a rA t e0W i h1W nt4S alK- ESA· R · Features Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions · · Easy to install Total solution for year round comfort 3 1 32 · Altherma · Sanitary Hot Water · Sanitary Hot Water · R-410A · EKSWW 2 2-1 Casing Dimensions Specifications TECHNICAL SPECIFICATIONS Colour Material Packing Height Width Depth Unit Height Width Depth mm mm mm mm mm mm kg kg 950 600 600 900 580 580 37 40 1200 600 600 1150 580 580 45 49 EKSWW150V3 EKSWW200V3 EKSWW300V3 EKSWW200Z2 EKSWW300Z2 Neutral white Epoxy-coated mild steel 1650 600 600 1600 580 580 59 64 EPS Carton kg Water volume Material Max. [. . . ] The higher the portion of energy supplied by the heat-pump, the more energy efficient the system is. Lowering the setpoint temperature increases the portion of energy supplied by the heat-pump and thus the efficiency of the system. Definition: Heat-pump portion Percentage of energy supplied by the heat-pump in the total energy need for sanitary hot water. Heat-pump portion Setpoint temp. (°C) Conditions: Real life condition Outdoor temperature Room temperature Outdoor unit type Tank type Field settings Simulation of a daily usage based upon medium usage pattern. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN ALTHERMA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN ALTHERMA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.