User manual DAIKIN BRC1B61

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAIKIN BRC1B61. We hope that this DAIKIN BRC1B61 user guide will be useful to you.


DAIKIN BRC1B61 : Download the complete user guide (786 Ko)

Manual abstract: user guide DAIKIN BRC1B61

Detailed instructions for use are in the User's Guide.

[. . . ] 2 CLOCK FUNCTION The clock functions are: · 24 hours real time clock, · day of the week indicator. 3 SCHEDULE TIMER FUNCTION The schedule timer functions are: · a maximum of 5 actions can be programmed for each day of the week (totalling 35 actions), · schedule timer can be enabled/disabled at any time, · linked to a set temperature or a LIMIT operation or an OFF operation, · "last command" overrules previous command until next scheduled command. 4 LIMIT OPERATION Limit operation provides thermostat control within the range of the set minimum and maximum temperature. The minimum temperature setting will trigger heating, the maximum temperature setting will trigger cooling. WARNING - Never let the remote controller get wet, this may cause an electric shock or fire. [. . . ] 2 DRY OPERATION In this mode, the air humidity will be lowered with a minimal temperature decrease. The temperature and fan speed are controlled automatically and cannot be controlled by the remote controller. 3 AUTOMATIC OPERATION Defrost (heat pump types only) In heating operation, freezing of the outdoor heat exchanger may occur. If so, the heating capacity of the system lowers and the system goes into defrost operation. After maximum 10 minutes of defrost operation, the system returns to heating operation again. 6 LIMIT OPERATION & Limit operation is an additional mode that enables to keep the room temperature within certain limits. The & icons are displayed to confirm the activation of the limit operation. 7 LEAVE HOME LEAVE HOME is a feature that enables to keep the room temperature above 10°C when the occupants are out. This function will switch on heating if the installation is switched off. In this mode, the controller will automatically switch between heating and cooling as required by the setpoint or limit temperature. 4 COOLING OPERATION In this mode, cooling will be activated as required by the setpoint or limit temperature. Operation Manual operation In manual operation, the user decides about the settings of the installation. Press the button to enter the browse mode, the icon appears, will blink. NOTE Browsing always starts on Monday and ends on Sunday. Continue pressing the button until the day of the week indicator displays the current day (not blinking), you have now quit browsing. NOTE The number of times that the button will have to be pressed to quit browsing depends on the number of programmed actions in the schedule timer. Check the icon. The clock indicates the time when the programmed action is scheduled, either , or and is being displayed. NOTE The temperatures mentioned above are for clarifying purposes only, temperature values on your controller may vary. How do I interpret the programmed actions To be able to understand the behaviour of your installation when the schedule timer is enabled, it is important to look at all programmed actions for the current day and maybe the last programmed action of yesterday. If the first programmed action for today is not active yet, the current status of your installation depends, most probably but not necessarily, on the last programmed action from yesterday. If the first programmed action for today is already active, the current status of your installation depends, most probably but not necessarily, on the parameters programmed in the first programmed action for today. NOTE To keep the operation of your installation simple, the schedule timer settings can easily be overruled by altering the current setting ("last command" overrules previous command until next scheduled command). If does not appear, it indicates that there are no programmed actions for Monday. will blink, this indicates that the programmed actions for Tuesday are being browsed. The clock indicates the time when the programmed action will be enabled, either , or and is being displayed. If does not appear, it indicates that there are no programmed actions for Tuesday. [. . . ] This is done by pressing the button, the data is saved and the next schedule timer action can be programmed. Programming the remaining schedule timer actions for the same day is similar. NOTE Don't worry if you add additional schedule timer actions by pressing the button repeatedly, they can be deleted when finishing the current day. Program mode is quit and depending on the choice made, the programmed actions are saved for Monday (and possibly Tuesday). PROGRAMMING THE OTHER DAYS OF THE WEEK Programming the other days of the week is identical to programming the first day of the week. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN BRC1B61




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN BRC1B61 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.