User manual DAIKIN DCS302C51

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAIKIN DCS302C51. We hope that this DAIKIN DCS302C51 user guide will be useful to you.


DAIKIN DCS302C51 : Download the complete user guide (1596 Ko)

Manual abstract: user guide DAIKIN DCS302C51

Detailed instructions for use are in the User's Guide.

[. . . ] OPERATION MANUAL CENTRAL REMOTE CONTROLLER MODELS English DCS302C51 Deutsch Français Español Italiano Ü Nederlands Portugues Read these instructions carefully before installation. Lesen Sie diese Anleitungen vor der Installation sorgfältig durch. Dieses Handbuch sollte immer im Besitz des Geräteeigentümers verbleiben. Rangez ce manuel dans un endroit pratique pour pouvoir vous y reporter par la suite. [. . . ] Setting to 1° above or below the temperature setting range displays " ". 6 [Registration] 1. Pressing the "ALL/INDIVIDUAL" button for four seconds. 2 Displays ZONE SET. 1 4. Call up the desired mode by pressing the "OPERATION MODE SELECTOR" button. Set to " " when you do not wish to use batch setting for the operation setting. 7 Zone Number 1 will be displayed, and if there are any groups already registered in the displayed zone, a " " will light up on the operation monitor. 7 English 2. Select the Zone Number to be registered using the "ZONE NUMBER" button. Keeping the button pressed down will move it rapidly. 3 [Batch deletion of zone registration] 1. 3. 5 " " to the group you wish to 4 reg- ister using the arrow keys. Keeping the button pressed down will move it rapidly. Pressing the " " for at least four seconds while 8 pressing the "FILTER SIGN RESET" button when 2 "ZONE SET" is displayed will delete all zone registrations. 9 The zone registrations for all units will be lost. 4. Press the "SELECT" button to register that group to the zone. The " units. 7 6 Zone operation and stop method (Fig. 7) This is for operating or stopping connected units in zones. " display lights up on all the selected [Zone operation] Pressing the "RESET" button removes " goes 1. 2. the group from that zone, and " off. Press the "ALL/INDIVIDUAL button" to enter the zone screen. 1 Repeat steps 3 and 4 until all the units you wish to register to the zone have been added. Using the arrow keys, select the zone number to operate or stop. 3 Pressing and reduces the zone number 2 while and raise the number. · If the zone number is displayed as "---, " this indicates that no units are registered in a zone. (See page 7) 3. In this example, a screen is shown with units 1-00, 1-02, 1-03, and 2-00 registered to Zone Number 1. 4 Press the "SELECT" button. " display lights up in the group. The " 5 Press the "RESET" button. " display goes off in the group. 5. Repeat steps 2 to 4 to register to the next zone. The " 6. Once zone registration is complete, 1 press the "ALL/INDIVIDUAL" button to turn off "ZONE SET" display and return to the individual screen. 4. Press the "TEMPERATURE ADJUSTMENT" button. 6 The display returns to the normal screen if nothing is done for one minute when in zone registration mode. (NOTE) · It is impossible to register one group to several different zones. If this is done, the last zone registered to will be valid. The temperature rises 1° every time the ( ) button is pressed. Set to " " when you do not wish to use zone setting for the temperature setting. Setting to 1° above or below the temperature setting range displays " ". 5. Call up the desired mode by pressing the "OPERATION MODE SELECTOR" button. 7 Set to " " when you do not wish to use zone setting for the operation mode. English 8 Changing the fan direction and fan strength (Fig. 8) This changes the fan direction and strength settings in the air conditioner. Changing the fan direction and strength is done in the individual screen. 3. Press the "VENTILATION MODE" button. 5 It will scroll through " " 6 "" "" " ". [Registration] Press the "VENTILATION STRENGTH ADJUSTMENT" button. It will scroll through " " H FRESH UP L 1. 1 Press the "ALL/INDIVIDUAL button" 2 "" H "" L " FRESH UP to enter the individual screen. The unit will enter the individual screen automatically if nothing is done for one minute. "" L ". 2. " 3 Using the arrow keys, 4 move the " to select the units to fan direction adjustment or fan strength adjustment. Keeping the button pressed down will move it rapidly. The fresh up function may not be available depending on the connected unit model. Pressing a button for a function which is not available will cause "NOT AVAILABLE" to be displayed. · Ventilation Mode and Amount If these are changed using the remote controller depending on the unit model, they cannot be displayed on the central remote controller. To monitor the ventilation mode and amount, check the values on the remote controller. 3. Press the "FAN DIRECTION ADJUSTMENT" button. This sets "fixed" or "swing" for the fan direction. 5 Press the "FAN STRENGTH ADJUSTMENT" button. Pressing this button scrolls through " and " HH ". Pressing a button for a function which is not available will cause "NOT AVAILABLE" to be displayed. L L 6 Timer Number Setting (Fig. 10) (Only when used with the schedule timer) Using this together with the schedule timer makes it possible to set on and off times four times a day. ", " H ", " and " H " [Registration] 1. Pressing the "TIMER NO. " button causes the number set for timer number 1 to blink. 1 Changing the ventilation mode and ventilation strength (Fig. 9) This changes the ventilation mode and strength settings in the total enthalpy heat exchanger. Changing the ventilation mode and strength is done in the individual screen. If no timer setting has been made " " will be displayed. [. . . ] The appearance of the above display is a sign that the air filter or air cleaner element of some group still needs cleaning. In this example, individual units 1-00, 1-03, 1-05, 1-06, 1-07, 2-02, and 2-03 are in the same system, and 1-05 has the cooling/heating selection privilege. To look up other systems, call up all the units you wish to look up using the arrow keys. Pressing the inspection/test run button one more time gets rid of the system display and ends it. The unit will enter the individual screen automatically if nothing is done for one minute in the system display screen. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN DCS302C51




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN DCS302C51 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.