User manual DAIKIN DCS601B51

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAIKIN DCS601B51. We hope that this DAIKIN DCS601B51 user guide will be useful to you.


DAIKIN DCS601B51 : Download the complete user guide (3202 Ko)

Manual abstract: user guide DAIKIN DCS601B51

Detailed instructions for use are in the User's Guide.

[. . . ] Operation Manual intelligent Touch Controller Before use Safety Instructions System Overview Features and Functions Part Names and Functions Part Names on the Monitoring Screen and the Functions List Icon 9 11 Operation Operation Quick Reference Air Conditioner Operation Monitoring the Operation of Air Conditioner System Setup Menu 13 14 22 25 Maintenance Precautions Maintenance Model LCD Maintenance When Leaving the Product Turned OFF for a Long Time 56 57 57 58 DCS601B51 Troubleshooting For Your Information Thank you for purchasing intelligent Touch Controller. This operation manual contains notes for safe use of the product. For correct use, be sure to read this manual carefully before use. Store this manual close at hand so that it can be referred to as required. Error Diagnostic Functions Options Double intelligent Touch Controllers Specification After-sales Service 65 67 67 68 69 Use smart and save smart We use recycled paper for making this operation manual. For Your Information Maintenance Operation Before use Be sure to follow the instructions below 1 3 4 5 Safety Instructions Be sure to follow the instructions below Read the manual carefully in advance for correct use Instructions given here are classified into the following two categories. Instructions in both categories are important for safety and must be duly followed. Warning Caution Failure to follow the instruction may lead to serious consequences including death or serious injury. Failure to follow the instruction may cause injury or material damage, which, in some cases, leads to serious consequences. The symbol given in the manual shows the following: Do not attempt to do things described in the instruction. [. . . ] Change Over : Enable/Disable Slv R/C : Mst/Slv Cool/Heat Option : With/Without Ou/Unit Addr : Address of the outdoor unit Err Type : Normal; Error code when any error is generated Err Code : 2-digit error code when any error is generated Err Unit No : 0 when there is no error Unit No. when error is generated Rm Temp : Inlet temperature of the indoor unit [ Zone ] Name Description ID Start 1 by 1 Interval Registered Grp No Schedule Slv R/C Cool/Heat Option Ou/Unit Addr Err Type Err Code Err Unit No Rm Temp : Zone name : Zone description : 0 - 63 : Enabled/Disabled : Interval when Enabled is set for the above : The number of groups registered for a zone : Enabled/Disabled : Mst/Slv (*1) : With/Without (*2) : Address of the outdoor unit (*3) : Normal; Error code when any error is generated (*4) : 2-digit error code when any error is generated (*4) : 0 when there is no error Unit No. when error is generated (*4) : Inlet temperature of the representative group for a zone (*1) For detailed information on a zone, the indication (*1) is Mst when there is any master R/C is included for air conditioners in the zone and Slv when all of them are slave R/C. The indication (*2) is Enabled when any of the air conditioners in the zone has the Cool/Heat option and Disabled when none of them has the option. The indication (*3) shows information on the representative unit for a zone and the error-related indications (*4) show information on any air conditioner generating an error. For monitoring further detailed information, 3. Press theAdvanced Function appears as shown Advanced Func button Screen 3 i. on the following page. To go back to Screen 1 Monitoring, press the Cancel button o. 23 Screen 3 Advanced Operation Continued from the previous page The contents of Display on Screen 3 Advanced Operation are as shown below. 10 14 11 15 12 16 13 17 !0Filter Sign Status When Yes/No is shown in black, the filter sign is illuminated. !1Element Sign Status When Yes/No is shown in black, the element sign is illuminated. (The example on the left shows the filter sign illuminated. ) !2Shows the current wind direction. Indicated with a figure between 0 and 7 inclusive. The larger the value for wind direction setting (0 - 6), the closer to vertical the direction becomes. (Note: See below. ) The description given above may not exactly apply depending on the model. Check the wind direction sign on the remote control after operation. !3Shows the current wind volume. Low or High is shown. !4Shows the remote control setting for starting or stopping operation. One of the following is shown: Prohibited Stop Only Permitted !5Shows the remote control setting for the operation mode. One of the following is shown: Prohibited Permitted !6Shows the remote control setting for the temperature setting. One of the following is shown: Prohibited Permitted have 4. When all the settingsCancelbeen !7. confirmed, press the button Screen 2 Operation on the previous page reappears. Pressing the Cancel button o on that screen brings you back to Screen 1 Monitoring. Caution This screen is for both operation and monitoring. When you have used the screen for monitoring only, press the Cancel button rather than the OK button to exit the window to prevent wrong operation. Note: Guidelines for wind direction value and actual direction Indoor unit 0 4 5 6 7: Wind direction auto swing 24 Operation System Setup Menu The System Setup menu includes the following items: · Password Setup · Time Zone Setup · Time Setup · Backlight Setup · Group Setup · Zone Setup · Schedule Setup · Change Over Settings · Temperature Limit Settings · Heating Optimization Settings System Setup Menu Item Password Setup · History Display · Touch Panel Calibration · Version Information The following table describes the items mentioned above. Description Setting a password allows restriction of access to the System Setup menu operation to specified personnel Note : If the set password is lost, access to all System Setup menu operation is denied. It is necessary to set Time Zone of intelligent Touch Controller according to your service place. And when it is needed to set Daylight Saving Time, setting may be made by this menu. Note : Setting Time Zone Setup may affect upon schedule operation, electric proportional distribution, and demand operation. And as for electric proportional distribution and demand operation, refer to their respective operation manuals. Time goes ahead 60 minutes at the start of Daylight Saving Time, while time goes back 60 minutes at the completion. [. . . ] · It prevents overheating of or condensation from forming on equipment which needs to be temperature controlled in unmanned rooms. · It can also help buildings and not just individual rooms to preserve heat by preventing unmanned rooms from reaching extremes of temperature at night. Operation (Reference) <Overview of Function> This function performs automatic control by monitoring the relationship between the set upper and lower limits and the room temperature (the air conditioner intake temperature) to prevent the set room temperature from exceeding those limits. This function starts and stops the air conditioners and changes the operation mode. · Cooling operation control (and stop control) Cooling operation is automatically started when the room temperature rises above the set upper temperature limit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN DCS601B51




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN DCS601B51 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.