User manual DAIKIN DCS601C51

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAIKIN DCS601C51. We hope that this DAIKIN DCS601C51 user guide will be useful to you.


DAIKIN DCS601C51 : Download the complete user guide (7853 Ko)

Manual abstract: user guide DAIKIN DCS601C51

Detailed instructions for use are in the User's Guide.

[. . . ] Operation Manual intelligent Touch Controller Before use Safety Considerations System Overview Features and Functions Part Names and Functions Part Names on the Monitoring Screen and the Functions List Icon 7 9 Operation Operation Quick Reference Air Conditioner Operation Monitoring Operation of Air Conditioner System Setup Menu 13 15 26 32 Precautions Maintenance Model LCD Maintenance When Leaving the Product Turned OFF for a Long Time 83 84 84 85 DCS601C51 ¡Thank you for purchasing intelligent Touch Controller. ¡This operation manual contains notes for safe use of the product. Troubleshooting For Your Information Options Specification After-sales Service For correct use, be sure to read this manual carefully before use. ¡When you have read this manual, be sure to store it in a place where the operator can conveniently refer to at anytime. In case of personnel change, be sure to give the manual to the new operator. 93 94 95 Use smart and save smart For Your Information Maintenance Maintenance Operation Before use Be sure to follow the instructions below 1 3 4 5 Safety Considerations Please read these "SAFETY CONSIDERATIONS" carefully before installing air conditioning equipment and be sure to install it correctly. After completing the installation, make sure that the unit operates properly during the start-up operation. [. . . ] * : The mark represents occurrence of a malfunction and the mark represents recovery from the malfunction. Operation (Reference) See pages 77 to 78 Normal state 3 minutes from i occurrence of the malfunction (wait for sending) Resend state Normal state Sending time interval Sending time interval 1 Group A 2 Group B 3 Group C 4 5 Group D Send the malfunctions occurred in Group A, B, C Send the malfunctions occurred in Group B, C, D Group B : The malfunction persists. Group D : Another malfunction has occurred. If no malfunction is found, the system will send no e-mail and go back to the normal state to start monitoring the air-conditioning unit. Figure : Timing of E-mail Sending 48 Operation System Setup Menu Item Description ¡Contents of E-mail The contents of the e-mail to be sent is described below. When three or more events of malfunctions have been occurred concurrently, the latest two events are displayed in ascending order and the rest is represented just as the total number of such events. Operation (Reference) See pages 77 to 78 From : user012@daikin. co. jp To : user012@daikin. co. jp Subject : Fault occurs (DAIKIN Head Office) 04/02 14:11 Office A9 04/02 14:10 ConfRoom E0 Remaining mails : 1 Originating e-mail address Destination e-mail address Fixed string of characters and controller name Date of occurrence of the malfunction (month, day, hour, minute) in ascending order starting from the latest one, group name, error code Number of the remaining malfunctions except two indicated above when three or more malfunctions exist ¡Operation when failing to send an e-mail When failing to send an e-mail, it will be resent three times at an interval of two minutes. Resending an e-mail will not be executed, however, in the following situations : · The POP sever returned an error of user authentication. · A test run mail was sent. ¡E-mail outgoing history The history file can contain a maximum number of 300 events of successes / failures in sending e-mails. * For detailed information, refer to the history display of P76. 49 System Setup Menu Item Simple Interlock Setting Description This menu is used to make settings of an interlock control function in units of zones or groups. The simple interlock control is a function to automatically control groups or zones corresponding to a change of the operation states or the stop states in any groups. · The simple interlock can store a maximum number of 128 program registrations. For each program, the following settings can be made : · Interlock input point The target groups you want to monitor as the interlock input points (e. g. * : Monitoring is performed for the input states at the operation / stop connection point. · Interlock output "Select conditions of interlock input points", "Registration of control targets", and "Settings of control details" are performed. · "Select condition of interlock input points" The interlock control function is initiated when the groups specified as the interlock input points indicate the operation states described below. (The control function is actually initiated when the state of the input point has changed. ) (1) No detection : Detection of inputs is not performed. (The control function is not effective. ) (2) Any one or more of the groups ON : When any one or more of the groups registered as the input points turn on, the control function is initiated. (3) All ON : When all of the registered groups as the input points turn on, the control function is initiated. (4) Any one or more of the groups OFF : When any one or more of the groups registered as the input points turn off to stop, the control function is initiated. (5) All OFF : When all of the registered groups as the input points turn off to stop, the control function is initiated. *1 Selecting "Any one or more of the groups ON (or OFF)" while some interlock input points are already ON (or OFF) will not initiate anew the interlock control function even when another interlock input point turns ON (or OFF). (Once the selected condition has become invalid and then, when the selected condition is satisfied again, the function can be initiated. ) *2 When a communication error occurs in any of the interlock input points, the condition will be checked only for the interlock input points in the normal communication state. Operation (Reference) See pages 79 to 80 · "Registration of control targets" A single group or zone, which is to be controlled when the interlock condition is met, is registered. * If the interlock condition has been met during a communication error in the control target, the interlock control function will not be initiated even when the communication error is cleared. · "Settings of control details" Details of the control operations for the target device where the interlock condition is met are defined. : Start Command and Change Temperature Setting) · Start / Stop commands · Operation mode switching · Change temperature setting · Setting of permission / prohibition of hand-held remote controller operations (Start / Stop, Temperature setting, Operation mode switching) · Ventilation mode switching (*) · Ventilation amount switching (*) * for HRV For one interlock program, two interlock outputs at the maximum can be specified. 50 Operation System Setup Menu Item Description Control operations when a communication error occurs in the interlock input points Example 1) When a communication error occurs in any of the interlock input points, the condition will be checked only for the interlock input points in the normal communication state. 1-00 1-01 1-02 1-03 Operation (Reference) See pages 79 to 80 When "All ON" is selected, the state change shown in the left figure can initiate the interlock control function. Example 2) Even if the interlock input point recovered from the communication error meets the specified condition, the interlock control function cannot be initiated. 1-00 1-01 1-02 1-03 When "Any one or more of the groups ON" is selected, the state change shown in the left figure cannot initiate the interlock control function. Example 3) When a communication error occurs in an interlock input point and, consequently, the specified condition is met, the interlock control function cannot be initiated. 1-00 1-01 1-02 1-03 Even when "All OFF" is selected, the state change shown in the left figure cannot initiate the interlock control function. Control operations when a communication error occurs in the control target equipment Condition of interlock input interlock input point 1-00 1-01 1-02 1-03 Control target equipment 1-10 points : "All ON" is selected. The condition of interlock input points is not met. (1) (2) Although the condition of interlock input points is met, the communication error in the control target will not allow initiating the interlock control function. Even when the control target recovers from the communication error, the interlock control function is not initiated. (3) (4) In this case, once the condition of interlock input points has become invalid and then, when the condition is satisfied again, the interlock control function can be initiated. (5) 51 System Setup Menu Item Description In the following section, utilization of the simple interlock control function is described while giving some examples. [. . . ] Description and Corrective Action Is the indication System Compulsory Stop on the Monitoring screen, as shown below?When compulsory stop command is input to central management devices (central remote controller, ON / OFF controller, etc. ) including the intelligent Touch Controller, the indication appears. Inputting compulsory command stops all air conditioners connected to the central management device. While the command is input, neither the central management devices nor remote control can operate air conditioners. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN DCS601C51




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN DCS601C51 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.